Product Specifications

HXC50178 — Discrete & Power Semiconductors | Superb Automation

HXC50178

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXC50178 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXC50178: 50 W per side on a 12.5 V rail with 17 dB and 77 per cent published

The HXC50178 is an LDMOS RF power transistor from Hisiwell on the HF table with a 0.5 GHz top frequency, a 50 times two output row, 17 dB of gain and 77 per cent drain efficiency. It runs on a 12.5 V rail in CW. On this table it is the lowest voltage part and the highest efficiency part.

Twelve and a half volts is the rail of a battery, not of a bus. That makes this row the one to look at for portable, handheld and vehicle accessory equipment in the HF to 500 MHz range, where the supply is a lead acid battery or a pack and every point of efficiency shows up directly in run time and in heat inside a sealed case.

Seventy seven per cent is the highest efficiency figure the vendor publishes on this table, and it is 12 points above the 65 per cent row next to it. At 100 W of output that difference is 15 W of heat in a handheld enclosure, which is the difference between a warm case and a case that cannot be held.

The HXC50178 rows as the vendor publishes them

Part classLDMOS RF power transistor, push pull pair
Frequency range, index rowHF to 0.5 GHz
Top frequency in MHz, calculated500 MHz
Quarter wavelength at the top, calculated150 mm in air
Saturated output, index row50 W times two
Pair total, calculated100 W, 50.00 dBm
Per side, calculated50 W, 46.99 dBm
Gain, index row17 dB
Drive for 100 W at 17 dB, calculated2.00 W, 33.00 dBm
Drain efficiency, index row77 per cent
DC input at 77 per cent, calculated129.9 W, 10.4 A at 12.5 V
Heat to remove, calculated29.9 W
Drain rail, index row12.5 V
Load voltage at 100 W into 50 ohm, calculated70.7 V rms, 100.0 V peak
Peak against the rail, calculated8.00 times
Load voltage per side at 50 W, calculated50.0 V rms, 70.7 V peak, 5.66 times the rail
Peak at a two to one mismatch, calculated200.0 V
Load line resistance for 100 W on a 12.5 V rail, calculated0.78 ohm at the fundamental
Mode, index rowCW
Package and flangeNot published
Thermal resistance, junction to caseNot published
Load impedanceNot published, no load pull table
Data sheetNone reachable for this row

100 W from 12.5 V: the highest rail ratio on the table

100 W into 50 ohm is 70.7 V rms and 100.0 V peak, which is 8.00 times a 12.5 V rail. That is among the largest ratios on this table, exceeded only by the 2 kW pair at 150 MHz at 8.94 times, and in practice it means the output network has to transform a load line near 0.78 ohm up to 50 ohm, a ratio of about 64 to 1.

A 64 to 1 transformation at 500 MHz is done in at least two sections and usually three, and the loss in that network is the price of the low rail. At 0.5 dB of network loss, 11 W of the 100 W never reaches the antenna and becomes heat next to a device that is already dissipating 30 W. This is the reason a 12.5 V product has to be treated as a network problem as much as a device problem.

The current is 10.4 A from a 12.5 V rail at 77 per cent efficiency. For a battery pack that is a significant draw: a 10 Ah pack at 10 A lasts an hour, so a transmitter at this power is a short duty cycle product or a vehicle mounted one. The high efficiency is what makes the duty cycle possible at all.

What 77 per cent buys in a sealed enclosure

At 100 W output and 77 per cent efficiency the part dissipates 29.9 W, against 82 W for the same output at 55 per cent. In a handheld or a sealed box, 52 W of difference is the whole thermal budget. That is why this row exists: at 12.5 V and 100 W the alternative rows are simply not usable in a sealed case.

The efficiency is a class figure and the vendor does not state the frequency or the drive at which it was measured. A buyer should expect it to hold near the centre of the band and to fall at the edges, and should measure at the two edges before committing the thermal build. On a part with a 64 to 1 output transformation, the network loss at the band edges can easily eat the efficiency advantage.

There is a second thermal path that matters at this size: the flange to the case, and the case to the ambient. At 29.9 W a 0.5 K per watt interface adds 15 K, which is acceptable, but a 2 K per watt interface adds 60 K, which is not. The interface material is a real decision on a 12.5 V part because the enclosure is usually small and the airflow is usually none.

Where a 12.5 V pair at 500 MHz is used

Portable radio equipment, vehicle accessories, manpack systems and battery powered industrial tools. In all of those the rail is fixed by the battery and the constraint is heat rather than power. A 100 W output is at the top of what a handheld can dissipate, and the published 77 per cent is what makes it possible.

The band matters too. HF to 500 MHz covers the whole of the land mobile VHF and UHF range in one part, which is unusual on this table, and it means one device can serve a product family that spans several bands with different output networks. The network is the variable and the device is the constant, which is a useful property for a builder shipping several models from one bill of materials.

What the row does not publish is linearity, bias point, temperature behaviour or ruggedness. For a portable product all four matter, and none of them can be inferred from the row. A buyer who needs to know how the part behaves at 60 C case temperature has to ask.

Where the HXC50178 sits on the table

The other 12.5 V rows on this table are a 30 W single ended part and a 20 W single ended part, both at 500 MHz, so this pair is the top of the low voltage group. Against the 28 V 300 W pair it is 4.77 dB lower in output and runs from a rail that is less than half, which is the trade a portable product makes.

Against the 50 V rows at the same band it is 5.4 dB to 11.5 dB lower, so it is not a substitute for a transmitter part. It is a different product category: the 50 V rows are for mains powered transmitters, this row is for battery powered equipment. The rail, output and drive comparison is on the RF power transistor cross reference page.

The efficiency figure also makes it the reference row for anyone comparing LDMOS against older bipolar parts at this voltage, because 77 per cent at 500 MHz is the number that decides whether a battery product is feasible at 100 W.

Buying the HXC50178: what the order has to state

State the sub band, the rail with its tolerance, the mode, the flange and body, the quantity, and whether the 17 dB and 77 per cent are guaranteed at a stated frequency and temperature. On a battery product the rail tolerance is not a formality: 12.5 V nominal with a 10 per cent window changes the load line and the output.

The incoming test should record gain, output and drain current at the rated drive and at two rail voltages inside the stated window, plus the quiescent current at the bias point. A pair that meets its numbers at 12.5 V and falls apart at 11.5 V is a field failure waiting to happen, and the second point costs nothing to measure. The record format is on the incoming inspection plan page.

For a portable product the device is bought with the driver, the output network passives, the battery connector and the thermal interface, and consolidating those against one date and one test plan is what the one stop RF supply page covers.

Questions buyers ask about the HXC50178

Is 100 W from one device? It is 50 W times two, so 100 W is the pair total at 50.00 dBm. Each half is 46.99 dBm.

How much drive? 17 dB of gain puts the drive at 2.00 W, which is 33.00 dBm.

What current does it draw? 10.4 A at 12.5 V and 77 per cent efficiency, for 129.9 W of DC input.

Will 77 per cent hold at the band edges? The row does not say at what frequency the figure was measured. Measure at both edges before the thermal build is frozen.

Can it run at 13.8 V? The row says 12.5 V. A higher rail raises the load line voltage and the current, so it needs a factory answer rather than a bench experiment.