Product Overview

The HXC50129 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXC50129: two kilowatts on HF to 150 MHz and the arithmetic a 50 V rail has to survive

The HXC50129 is an LDMOS RF power transistor from Hisiwell filed on the HF table with a 0.15 GHz top frequency and a 1000 times two output row. It is the largest part on that table and one of the largest on any table this vendor publishes. The row is a push pull pair: 1000 W from each side, summed into two kilowatts.

Two kilowatts at 150 MHz is not a microwave problem. It is a power supply, cooling and combiner problem with a transistor attached, and the buyer who reads the row as a single 2 kW device will get the drive, the current and the heat wrong by a factor of two. The vendor publishes no gain and no efficiency for this row, which means the two numbers that close a whole amplifier budget have to come from the factory or from a measurement.

The frequency column says HF to 0.15 GHz, so the window starts at the bottom of the HF range and stops at 150 MHz. In practice that covers shortwave broadcast, industrial RF heating, plasma generation, MRI transmit chains at the low end and FM broadcast at the top. It does not cover the 430 to 470 MHz land mobile band, and it does not cover 915 MHz.

The HXC50129 rows as the vendor publishes them

Part classLDMOS RF power transistor, push pull pair
Frequency range, index rowHF to 0.15 GHz
Top frequency in MHz, calculated150 MHz
Band ratio, calculatedWider than a decade from the bottom of HF
Saturated output, index row1000 W times two
Pair total, calculated2000 W, 63.01 dBm
Per side, calculated1000 W, 60.00 dBm
Sum of two equal halves, calculated3.01 dB above one side
Drain rail, index row50 V
Load voltage at 2000 W into 50 ohm, calculated316.2 V rms, 447.2 V peak
Peak against the rail, calculated8.94 times
Load voltage per side at 1000 W, calculated223.6 V rms, 316.2 V peak, 6.32 times the rail
Load voltage at a two to one mismatch, calculated894.4 V peak, which sets the capacitor and cable rating
DC input at 55 per cent, calculated3636 W, 72.7 A at 50 V, 1636 W of heat
DC input at 65 per cent, calculated3077 W, 61.5 A at 50 V, 1077 W of heat
Output per megahertz of window, calculated13.3 W
GainNot published
Drain efficiencyNot published
Mode, index rowCW
Package and flangeNot published
Thermal resistance, junction to caseNot published
Load impedanceNot published, no load pull table
Data sheetNone reachable for this row
Orderable addendumNone published
Packing quantity and moisture levelNot published

What two kilowatts does to a 50 ohm load and a 50 V rail

2000 W into 50 ohm is 316.2 V rms, which is 447.2 V peak, and 447 V sits 8.94 times above a 50 V drain rail. A tuned stage swings above the rail by construction, so the ratio itself is normal for a push pull pair at this power. What is not normal is the consequence: under a two to one load mismatch the peak doubles to 894 V, and every capacitor, cable, connector and balun in the output path has to be rated for it rather than for the matched figure.

The rail current is the second number that decides whether the part is usable in a given rack. At 55 per cent drain efficiency the pair draws 72.7 A from a 50 V bus and turns 1636 W into heat; at 65 per cent the current falls to 61.5 A and the heat to 1077 W. Neither figure is published by the vendor, so both are here as arithmetic on an assumed efficiency, and the assumption has to be replaced by a measurement before a heatsink is ordered.

At 150 MHz the wavelength in air is two metres, so the output network is built from discrete capacitors and a transformer rather than from printed lines. That is good news for adjustment and bad news for repeatability: the same network built twice from the same drawings can differ by a few tenths of a decibel, and at 2 kW a few tenths of a decibel is a hundred watts of heat somewhere unexpected.

One 2 kW device or two 1 kW halves

The multiplication in the power column is the first thing to read and the last thing buyers ask about. A push pull pair is two dies in one flange, driven in antiphase and combined in a balun, and the balun is not in the package on every part of this class. Where it is not, the buyer supplies it, and a 2 kW balun at 150 MHz is a substantial magnetic component in its own right.

Where the balun is inside, the amplifier is smaller but the part becomes a single source item: a failure takes out both halves and there is no way to match two devices from different batches. Where it is outside, the two halves can be selected and the balance measured, which is what a 2 kW industrial transmitter usually wants.

Either way the drive has to be split with the same care. Without a published gain figure there is no way to compute the driver from the row alone, and a 2 kW stage with 15 dB of gain needs 63 W of drive while the same stage with 20 dB needs 20 W. That 5 dB spread is the difference between a single driver board and a two stage chain, so the gain figure is not a detail.

Cooling and the mechanical envelope at this power level

1636 W of heat at 55 per cent is more than most forced air heatsinks will move without a large temperature rise. In practice a 2 kW HF stage is liquid cooled or mounted on a cold plate, and the flange is the interface that decides whether the thermal path works. The vendor publishes no thermal resistance, no flange drawing and no body dimensions for this row, so the mechanical interface has to be agreed from a drawing requested for the specific part.

There is a second thermal point that matters on HF parts and rarely appears in a budget: the output transformer and the balun carry the full current and sit next to the devices. Their losses are part of the heat load, and they are not included in any efficiency figure the vendor might give for the transistor alone. A 2 kW amplifier that meets its transistor efficiency target and still runs hot is usually losing the difference in the magnetics.

Then there is the supply. 72.7 A at 50 V needs a bus that holds its voltage under a pulsed load, and the wiring has to be sized for the current rather than for the average. A 2 kW stage fed through a long thin pair of leads will show a rail sag on every envelope peak, and the symptom looks like a transistor problem until the rail is measured at the flange.

Where the HXC50129 sits on the HF table

The rows below it are the 750 W pair at 200 MHz, the 500 W pair at 300 MHz and the 700 W pair at 500 MHz, each one a step down in power and a step up in frequency. The single ended parts start at 250 W on 500 MHz. Read as a ladder, the table offers 2 kW, 1.5 kW, 1.4 kW and 1 kW in pairs and 250, 170 and 80 W in single ended parts, and the choice is driven by the system power and by how much combining the buyer is willing to do.

The HXC50129 is the only row that claims the full 150 MHz top frequency with 2 kW, so it is the default for a shortwave broadcast transmitter. For a 200 MHz requirement the 750 W pair is the nearer match and gives away 1.25 dB, which is a smaller step than moving to a different vendor. The drive and output comparison for the family is on the RF power transistor cross reference page.

The table also mixes rails, and that matters here. The 50 V rows sit above the 28 V and 12.5 V rows in output, so a system built around a 28 V bus cannot reach 2 kW from this family without a converter. The 50 V rail is what makes the current manageable at this power, and it is also why the load voltage is nearly nine times the rail.

Buying the HXC50129: what the order has to state

The order has to state the frequency, the rail, the mode, the flange and body, the quantity, the gain and efficiency figures the factory is prepared to guarantee, and the thermal resistance. Without the last two, the acceptance test cannot be written. It should also state whether the balun is inside the part or supplied by the buyer, because that single answer changes the mechanical envelope and the price of the amplifier.

For the incoming gate, measure each half separately and then combined, and record the balance between the two. A pair that delivers 2 kW combined but 300 W of imbalance between halves is a pair that will fail early, and the imbalance will not show in a combined power measurement. The record format and the test sequence are set out on the incoming inspection plan page.

A 2 kW stage usually arrives as a bill of materials rather than as one line: devices, balun, output capacitors, current sense, driver, circulator and the cold plate. Consolidating those against one date and one test plan is what the one stop RF supply page covers, and on a build of this size the consolidation is worth more than a few points on any single line.

Questions buyers ask about the HXC50129

Is 2 kW available from one device? The row is 1000 W times two, so 2 kW is the pair total. Each half is a 1 kW device at 60.00 dBm.

How much drive does it need? The gain is not published, so the drive cannot be computed from the row. With 15 dB it would be 63 W, with 20 dB it would be 20 W, and the factory has to confirm which.

What efficiency should I plan for? Not published for this row. At 55 per cent the pair draws 72.7 A and makes 1636 W of heat; at 65 per cent, 61.5 A and 1077 W. Plan for the first until a measurement replaces it.

Is the balun included? Not stated. This has to be confirmed per order, because it decides the mechanical build and the combining loss.

What is the load voltage under mismatch? 894 V peak at a two to one mismatch. Size the output capacitors and the cable for that, not for the 447 V matched figure.