Contact Us

HXC50119

Brand: Hisiwell
Hisiwell HXC50119 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXC50119 — Discrete & Power Semiconductors | Superb Automation

HXC50119

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXC50119 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXC50119: a 250 W single ended part on HF to 500 MHz and the case for no balun

The HXC50119 is an LDMOS RF power transistor from Hisiwell on the HF table with a 0.5 GHz top frequency and a 250 W output row. No multiplication in the power column, so this is one device delivering one output, and that single fact changes more about the amplifier than the power level does.

On the rows above it the row is a pair, and a pair means a balun, a balance measurement and a combined output that can hide an imbalance. On this row there is one die, one flange and one output, so the stage is simpler to build, simpler to test and simpler to explain when something goes wrong. What it gives up is power: 250 W against 350 W for the pair one rung up and 1.4 kW for the largest 500 MHz row.

The row publishes no gain and no efficiency, as most rows on this table do. It does publish 250 W, a 50 V rail, CW and the HF to 500 MHz window, and from those the supply current, the load voltage, the heat at any assumed efficiency and the capacitor rating under mismatch can all be worked out. The rest of this page is that arithmetic, stated with its assumptions visible.

The HXC50119 rows as the vendor publishes them

Part classLDMOS RF power transistor, single ended
Frequency range, index rowHF to 0.5 GHz
Top frequency in MHz, calculated500 MHz
Quarter wavelength at the top, calculated150 mm in air
Saturated output, index row250 W
Output in dBm, calculated53.98 dBm
Step above the 170 W single ended row, calculated1.67 dB
Step below the 350 W pair, calculated1.46 dB
Drain rail, index row50 V
Load voltage at 250 W into 50 ohm, calculated111.8 V rms, 158.1 V peak
Peak against the rail, calculated3.16 times
Peak at a two to one mismatch, calculated316.2 V
Load line resistance for 250 W on a 50 V rail, calculated5.0 ohm at the fundamental, rail squared over twice the power
DC input at 55 per cent, calculated454 W, 9.1 A at 50 V, 204 W of heat
DC input at 65 per cent, calculated385 W, 7.7 A at 50 V, 135 W of heat
DC input at 70 per cent, calculated357 W, 7.1 A at 50 V, 107 W of heat
Output per megahertz of window, calculated0.5 W
GainNot published
Drain efficiencyNot published
Mode, index rowCW
Package and flangeNot published
Thermal resistance, junction to caseNot published
Load impedanceNot published, no load pull table
Data sheetNone reachable for this row

What a single ended 250 W stage costs and what it saves

250 W into 50 ohm is 111.8 V rms and 158.1 V peak, which is 3.16 times the 50 V rail. That ratio is low enough that the output network can be a simple low pass and a matching section rather than a transformer, and low enough that a 200 V ceramic capacitor is comfortable at the matched condition. Under a two to one mismatch the peak doubles to 316.2 V, so the same capacitor is no longer comfortable, and the rating has to be chosen against the mismatch rather than against the nominal.

The current draw is 9.1 A at 55 per cent efficiency, 7.7 A at 65 per cent and 7.1 A at 70 per cent. All three are ordinary figures for a 50 V bus, which means the supply does not need special treatment: a normal bulk capacitor bank and a connector rated for 10 A cover the stage with margin. Compare that with the 1.4 kW row built from two 700 W halves, which pulls 50.9 A at 55 per cent and needs a bus built around it.

The heat is 204 W, 135 W or 107 W depending on which efficiency the part actually reaches. The spread between the first and the last is 97 W, which is the difference between a modest extruded heatsink with a fan and a small one without. Since the vendor does not publish efficiency for this row, the honest position is to size for 204 W and treat anything better as margin.

The load line and why 5 ohm matters

A 250 W stage on a 50 V rail presents a fundamental load line near 5 ohm before the output network transforms it up to 50 ohm. That figure is arithmetic from the rail and the power, and it explains most of the practical behaviour of the stage: the output network is a 10 to 1 impedance step, which a two section low pass can still achieve at 500 MHz with a loss worth measuring.

The same arithmetic on the 1.4 kW row gives a load line near 0.9 ohm, which needs a much larger step and a correspondingly more lossy network. This is the reason high power RF stages lose efficiency in the combining and transforming, not in the transistor. On this part the transformation is easy, so the network loss can be held to a few tenths of a decibel, and the amplifier efficiency stays close to the device efficiency.

The second consequence of a 5 ohm load line is that the device is relatively insensitive to small errors in the network. On a 0.9 ohm stage a 2 mm error in a line length can move the match enough to lose 0.5 dB; on a 5 ohm stage the same error costs less. That is why single ended parts at this power level are popular in products built in modest volume with ordinary process control.

Where a single ended 250 W part fits in a system

The obvious use is a final stage in a 100 to 250 W transmitter for industrial, scientific or land mobile service. The less obvious use is as a driver for a much larger stage: 250 W is 53.98 dBm, which is a sensible drive level for a 2 kW pair that needs 63 W to 20 W depending on its gain, and for a 1.4 kW pair at 18 dB of gain which needs about 22 W.

For the driver role the important figure is linearity rather than saturated power, and this row publishes nothing about linearity, no two tone data, no peak to average handling and no bias point. A buyer who intends to drive a modulated signal through this part has to get those numbers from the factory or measure them, and the measurement is worth more than the row because it describes the part in the condition that matters.

The third use is a balanced pair of two single ended parts driven in antiphase. That gives the balance of a push pull stage without depending on a matched pair inside one package, and it allows a failed device to be replaced individually. The cost is two flanges, two networks and an external combiner, which at 250 W is a reasonable trade.

Reading the 500 MHz rows as a set

The 500 MHz band on this table is the most crowded: a 1.4 kW pair, a 900 W pair, a 1 kW pair, a 350 W pair, this 250 W single, a 170 W single, an 80 W single and a 30 W single. That is eight rows inside one band, which means a buyer can usually find the power level rather than combining to reach it.

Between 250 W and 170 W the step is 1.67 dB, which is small enough that the two rows are alternatives rather than a ladder. Between 250 W and 350 W the step is 1.46 dB, also small. The real steps are at 350 W to 1 kW, which is 4.56 dB, and at 1 kW to 1.4 kW, which is 1.46 dB. A buyer choosing between the 250 W single and the 350 W pair is choosing a topology, not a power level. The comparison of output, rail and band across the family is on the RF power transistor cross reference page.

One thing the table does not say is which rows share a package. Two rows with similar power and the same rail may still need different flanges, and that decides whether a product can be offered at two power levels from one mechanical build.

Buying the HXC50119: what the order has to state

State the sub band inside HF to 500 MHz, the rail, the mode, the flange and body, the quantity, and the gain and efficiency the factory will guarantee. State also the linearity condition if the part will carry a modulated signal, because a saturated CW figure says nothing about a signal with a peak to average ratio.

The incoming test should record output at the rated drive, gain at three frequencies, and the quiescent current at the intended bias. A single ended part is easier to characterise than a pair, and the whole record fits on one sheet, which is the standard described on the incoming inspection plan page.

Because 250 W is a driver level for larger stages, this part is often bought together with the device it drives. Buying the pair of power levels against one date and one test plan is what the one stop RF supply page covers, and it avoids the common situation where the driver arrives a month after the final stage.

Questions buyers ask about the HXC50119

Is it a pair or a single device? Single. The row has no multiplication, so 250 W comes from one die.

What is the current draw? 9.1 A at 55 per cent efficiency, 7.7 A at 65 per cent and 7.1 A at 70 per cent, all on a 50 V rail and all calculated.

What load line does it present? About 5 ohm at the fundamental, which is a 10 to 1 step to 50 ohm.

Does it need a circulator? The vendor publishes no ruggedness figure, so protection is a system decision. At 316 V peak under mismatch the output network needs protection or margin.

How much gain? Not published. Measure it before the drive budget is fixed.