Contact Us

HXC50115

Brand: Hisiwell
Hisiwell HXC50115 is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HXC50115 — Discrete & Power Semiconductors | Superb Automation

HXC50115

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HXC50115 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HXC50115: 700 W per side on HF to 500 MHz and the top of the 500 MHz band

The HXC50115 is an LDMOS RF power transistor from Hisiwell on the HF table with a 0.5 GHz top frequency and a 700 times two output row. One thousand four hundred watts from a 50 V rail in CW, which makes it the largest part on the table inside the 500 MHz band and the second largest pair the vendor publishes after the 2 kW HF row.

The order of the rows on that table is worth a second look, because the 500 MHz pair at 1.4 kW is larger than the 300 MHz pair at 1 kW and larger than the 200 MHz pair at 1.5 kW is close to. Frequency does not order the power on this table, and a buyer who assumes that a higher band always means a smaller part will misread the family.

What this part really is, is a way to reach a kilowatt and a half at 500 MHz with one flange and one balun. Everything else, the supply, the combiner, the cooling and the protection, follows from that.

The HXC50115 rows as the vendor publishes them

Part classLDMOS RF power transistor, push pull pair
Frequency range, index rowHF to 0.5 GHz
Top frequency in MHz, calculated500 MHz
Quarter wavelength at the top, calculated150 mm in air
Saturated output, index row700 W times two
Pair total, calculated1400 W, 61.46 dBm
Per side, calculated700 W, 58.45 dBm
Step above the 1 kW pair at 300 MHz, calculated1.46 dB
Step below the 1.5 kW pair at 200 MHz, calculated0.30 dB
Drain rail, index row50 V
Load voltage at 1400 W into 50 ohm, calculated264.6 V rms, 374.2 V peak
Peak against the rail, calculated7.48 times
Load voltage per side at 700 W, calculated187.1 V rms, 264.6 V peak, 5.29 times the rail
Peak at a two to one mismatch, calculated748.3 V
DC input at 55 per cent, calculated2546 W, 50.9 A at 50 V, 1146 W of heat
DC input at 65 per cent, calculated2154 W, 43.1 A at 50 V, 754 W of heat
Output per megahertz of window, calculated2.8 W
GainNot published
Drain efficiencyNot published
Mode, index rowCW
Package and flangeNot published
Thermal resistance, junction to caseNot published
Load impedanceNot published, no load pull table
Data sheetNone reachable for this row

1.4 kW, 50.9 A and 748 V under mismatch

1400 W into 50 ohm is 264.6 V rms and 374.2 V peak, which is 7.48 times the 50 V rail. That peak is the working voltage of the output network, and the network at 500 MHz is printed on a laminate with discrete capacitors in it, so the capacitor voltage class is the first component decision. A 500 V part covers the matched condition with margin and the mismatch at 748 V does not, so either a higher class or a protection scheme is needed.

The supply is the second decision. At 55 per cent efficiency the pair draws 50.9 A from a 50 V bus and generates 1146 W of heat; at 65 per cent, 43.1 A and 754 W. A 50.9 A draw means a bus with substantial copper, a connector rated well above the figure, and a bulk capacitor bank close to the devices so that the envelope current comes from capacitance and not from the feed line.

The third decision is the combiner. A 1.4 kW pair that is 0.3 dB out of balance dissipates about 100 W in the combining network, which at this power level is a hot spot rather than a rounding error. Balance is measured, not assumed, and it is measured at the frequency of use rather than at the centre of the window.

Why the 500 MHz band gets a 1.4 kW part

500 MHz is the band of UHF broadcast, of a number of industrial heating and plasma systems and of several military and public safety links. Transmitters in that band are typically between 500 W and 2 kW per channel, so a 1.4 kW pair covers the top of the range with one device and one balun rather than with four 350 W parts and a four way combiner.

The economics are the reason. Four 350 W parts give 1.4 kW at 3 dB of combining loss before any imbalance, which means the parts must be 2.8 kW of raw output to deliver 1.4 kW. One 1.4 kW pair has one combining stage and roughly 0.2 dB of loss. On a transmitter that runs continuously, the difference in electricity is larger than the difference in component cost over a year.

The counter argument is serviceability. A pair is one item, and a failure takes the whole channel off air. A four part build can lose one part and stay at three quarters power. Broadcasters with a redundancy requirement sometimes prefer the second arrangement even at the cost of efficiency, and that is a system decision the transistor row cannot make.

Cooling a kilowatt and a half at 500 MHz

1146 W of heat at 55 per cent efficiency is a liquid cooled or a heat pipe problem. The die is smaller than on the 200 MHz parts, so the flux per square millimetre is higher, and the flange area is the limiting factor rather than the heatsink. At this size the interface material is a mechanical element: a 0.1 K per watt interface adds 115 K at 1146 W, and no heatsink recovers that.

The output network also dissipates. At 500 MHz a printed network with 0.3 dB of loss adds 100 W inside the enclosure, next to components that are already at elevated temperature. A transmitter that meets its transistor efficiency target and still runs hot is usually losing the difference in the network and the combiner, and both are inside the thermal envelope of the same box.

The vendor publishes no thermal resistance for this row, so the junction temperature cannot be closed from the data available. That is the single most important missing figure on this page, and it is the one to request first when the part is quoted.

Where the HXC50115 sits on the table

Its nearest neighbours in output are the 1.5 kW pair at 200 MHz, 0.30 dB above, and the 1 kW pair at 300 MHz, 1.46 dB below. Both are on narrower windows in absolute terms and both are easier to cool because the die is larger at lower frequency. The nearest neighbour in frequency is the 350 W pair, which is 6.02 dB below and shares the band.

Read across the whole table, the power ceiling falls from 2 kW at 150 MHz to 1.4 kW at 500 MHz, and the pairs stay in the kilowatt range up to 500 MHz before the table stops. Above 500 MHz the vendor moves to a different table with different devices, so this row is the end of the HF family rather than a middle point. The output and rail comparison is on the RF power transistor cross reference page.

A buyer who needs 1.4 kW at 600 MHz has no row here and should look at the VHF to UHF LDMOS rows on the other tables before assuming that this part can be pushed.

Buying the HXC50115: what the order has to state

State the sub band inside HF to 500 MHz, the rail, the mode, the flange and body, the quantity, the gain and efficiency to be guaranteed, and the thermal resistance. On a 1.4 kW part the thermal resistance is not a detail, it is the number that decides whether the product can be built at all.

The incoming test should measure each half, then the pair, and record the balance. It should also record the quiescent current at the bias point, because a pair with a drifting bias will fail in the field long before its output falls. The record and the sampling plan are described on the incoming inspection plan page.

At this power the bill of materials around the device is larger than the device: balun, output capacitors, circulator, current sense, cold plate and driver. Consolidating them against one date and one test plan is what the one stop RF supply page covers.

Questions buyers ask about the HXC50115

Is 1.4 kW from one device? It is 700 W times two, so 1.4 kW is the pair total at 61.46 dBm. Each half is 58.45 dBm.

What is the current draw? 50.9 A at 55 per cent efficiency and 43.1 A at 65 per cent on a 50 V rail, both calculated.

Can it run above 500 MHz? The window stops at 500 MHz and the vendor publishes nothing above it for this row.

What output capacitor rating is needed? 748 V peak at a two to one mismatch, so 500 V parts are adequate only for a protected load.

How much gain? Not published, so the drive for 1.4 kW cannot be computed from the row. With 15 dB it would be 44 W and with 18 dB, 22 W.