HXC50156
Product Specifications
HXC50156
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HXC50156 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
Low Rds(on) for minimal conduction losses in power switching
Fast switching speed with low gate charge for high-frequency operation
Avalanche-rated for robust operation under inductive load conditions
High junction temperature rating for demanding environments
Logic-level gate drive compatible for simplified design
RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HXC50156: 40 W on 28 V, the only row here that publishes gain and efficiency
The HXC50156 is a 40 W unmatched LDMOS RF power transistor on a 28 V rail, filed on the HF to 1.5 GHz line with 20 dB of gain and 60 per cent efficiency published on the index, and marked CW. The vendor page adds that it can be used in Class AB, Class B and Class C for all typical modulation formats, and lists the same ten application bands as its neighbours. It is the only row in this batch that publishes both gain and efficiency, which makes it the most quotable part of the group.
Twenty-eight volts rather than 50 changes the arithmetic in a way buyers underestimate. 40 W into 50 ohm is still 44.7 V rms and 63.2 V peak, but against a 28 V rail that peak is 2.26 times the supply rather than 1.55. The device therefore works harder for the same output, and the current is higher: at 60 per cent efficiency the DC input is 66.7 W, which is 2.38 A at 28 V against 1.33 A for the same 40 W on a 50 V rail.
The trade is deliberate. A 28 V rail is what a vehicle, a battery bank or a 24 V industrial bus provides, and a part that runs directly from it removes a boost converter from the chain. The cost is 2.26 times the rail on the drain instead of 1.55, more current per watt, and a larger share of the system heat in the transistor. Whether that trade is right depends on the bus, not on the transistor.
The HXC50156 rows as the vendor publishes them
| Part class | LDMOS RF power transistor, unmatched |
| Frequency range, index row | HF to 1.5 GHz |
| Output, index row | 40 W |
| Output in dBm, calculated | 46.02 dBm |
| Power gain, index row | 20 dB |
| Drain efficiency, index row | 60 per cent |
| Drain rail, index row | 28 V |
| Mode, index row | CW |
| Classes of operation, vendor page | Class AB, Class B and Class C for all typical modulation formats |
| Load voltage at 40 W into 50 ohm, calculated | 44.7 V rms, 63.2 V peak |
| Peak against the 28 V rail, calculated | 2.26 times |
| Load voltage at a 2 to 1 mismatch, calculated | 126 V peak |
| Load voltage at a 3 to 1 mismatch, calculated | 190 V peak |
| Drive at 40 W and 20 dB, calculated | 0.40 W, 26.02 dBm |
| Power gain ratio, calculated | 100 times |
| DC input at 60 per cent efficiency, calculated | 67 W, 2.38 A at 28 V |
| Heat to remove at 60 per cent, calculated | 27 W |
| DC input at 55 per cent efficiency, calculated | 73 W, 2.60 A at 28 V |
| Heat to remove at 55 per cent, calculated | 33 W |
| DC input at 70 per cent efficiency, calculated | 57 W, 2.04 A at 28 V |
| Heat to remove at 70 per cent, calculated | 17 W |
| Thermal resistance, junction to case | Not published |
| Breakdown voltage and maximum ratings | Not published |
| Package | Not published on the row |
| Document link on the page | Points to the site root, no document served |
| Orderable addendum | None published |
| Moisture level and packing quantity | Not published |
Class AB, B and C on the same die, and what the choice costs
The page states that the part works in Class AB, Class B and Class C, which is a real choice rather than a marketing line, and the three classes give very different results at this power. Class AB with a quiescent current of 100 to 200 mA is the linear setting: it delivers the 20 dB of gain and 60 per cent efficiency in the index row, and it holds a modulated envelope without excessive distortion. Class B at near zero quiescent current gains a few points of efficiency and loses linearity on the envelope. Class C biases the gate below threshold, gains more efficiency still and delivers a constant envelope signal only.
For a CW or an FM application, Class C is the efficient choice and the 60 per cent in the row can often be beaten. For a multi carrier or a digital modulation, Class AB is the only honest choice and the average power has to be backed off. The same part in the same socket can be a 40 W CW amplifier or a 10 W linear amplifier, and the two are not interchangeable in a link budget.
The page also says the part supports all typical modulation formats, which is a statement about the die rather than about the bias. A Class C stage does not support a linear modulation format regardless of what the die can do. The bias network on the board decides the class, so the operating class belongs on the assembly drawing next to the quiescent current.
The 28 V rail: current, droop and the rest of the chain
At 60 per cent efficiency this part draws 2.38 A at 28 V. That is a current a vehicle harness can carry, which is the point of a 28 V part, but it is also a current that makes every milliohm in the supply path visible. A 100 milliohm path from the battery to the drain drops 240 mV at full power, which is nearly 1 per cent of the rail and shows as a tiny compression at the top of the drive range.
The second issue is the source of the 28 V. A 24 V industrial bus that sags to 21 V under load moves the operating point of a 28 V part by 25 per cent, and the gain and the compression point move with it. If the bus is not regulated, the amplifier needs either a boost stage in front of it or an acceptance test at the bottom of the bus range rather than at nominal.
The third issue is the driver. At 20 dB and 40 W the drive is 0.40 W, but that assumes 28 V on the drain. At 21 V the output falls and the gain falls, so the driver has to hold 0.4 to 0.5 W across the bus range. A driver that is itself fed from the same unregulated bus will lose output exactly when the output stage needs more drive, which is a compounding failure rather than a graceful one.
Thermal at 27 W of heat with a 28 V rail
At 60 per cent efficiency the heat is 27 W and at 55 per cent it is 33 W. Those are modest numbers and a 100 by 60 mm extruded sink with 20 mm fins moves them at a 35 degree rise by natural convection. The part is often used in a sealed roadside or vehicle enclosure, so the ambient inside the box rather than the outside air is the number that matters, and a sealed box at 27 W of internal dissipation runs 15 to 20 degrees above the outside air.
With no published thermal resistance, a planning figure of 1.5 degrees per watt for a device of this size gives 40 to 50 degrees of rise at 27 to 33 W and puts the junction at 125 to 135 degrees with an 85 degree case. That is comfortable, and it means the thermal work at this power is about the interface and the enclosure rather than about the die.
The measured route is still the right one for a production build: run at full power for thirty minutes, read the flange and the internal ambient, and compute the actual sink resistance. A first article that measures 40 degrees of rise is an assembly that works; one that measures 70 degrees needs a bigger sink or a different enclosure before the second build.
Where the HXC50156 sits and when to change rail
The same 40 W output is available on the 50 V rail from a smaller part with a 1.55 ratio and 1.33 A of current, and the same 28 V rail carries larger rows up to about 115 W per device elsewhere on the shelf. So this row is not the only 28 V answer, it is the 40 W rung of the 28 V ladder, and the choice between it and the 50 V equivalent is a system decision about the bus.
The rule of thumb is simple. If the product already has a 28 V bus and no room for a converter, take this row and accept 2.26 times the rail and 2.38 A. If the product has a 48 or 50 V bus, take the 50 V rung and gain efficiency and current. Mixing the two rails in one amplifier chain costs a converter and its loss, and at 40 W that loss is a larger share of the budget than at 400 W.
The band is the second decision. This row covers HF to 1.5 GHz, which includes the 1.2 to 1.4 GHz L band where the 28 V rows of 45 W and above also sit. A buyer who needs 1.3 GHz at 40 W has more than one option, and the comparison across the band and the rail is on the RF power transistor cross reference page. The passives for a 28 V stage, where the current is 2.4 A and the mismatch voltage reaches 190 V, are on the RF component sourcing page, and the supply side for a part with no published document is on the one stop RF supply page.
One last point on the documentation. The data sheet link on this page points at the site root and serves no document, and the index row carries the gain and efficiency but no thermal or maximum ratings. A buyer who needs those figures has to request them, and until they arrive the numbers in this page are the published row plus arithmetic, which is a fair basis for a first article and not a basis for a production release.
Questions buyers ask about the HXC50156
28 V or 50 V for 40 W?
It depends on the bus, not on the transistor. On 28 V this part draws 2.38 A and swings 2.26 times its rail; on 50 V a comparable part draws 1.33 A and swings 1.55 times. If the product already has a 28 V bus, this row removes a converter and its loss. If it has a 48 or 50 V bus, the 50 V rung is the better electrical choice.
What efficiency can Class C reach?
No figure is published beyond the 60 per cent on the index row, which is the Class AB number. Class C on a constant envelope signal normally beats it by several points, but the part is then unusable for a linear modulation. Ask the vendor for the Class C row at the intended frequency before quoting an efficiency to a customer.
What happens if the 28 V bus sags to 21 V?
Output falls roughly with the square of the rail, so 40 W becomes about 22 W, and gain falls as well, which means the driver has to deliver more to hold the same output. On an unregulated bus the acceptance test should be run at the bottom of the range, and the driver should be fed from a regulated rail rather than from the same sagging bus.