Arc Lamp Igniters and Xenon Lamp Power Supplies
Product Specifications
Product Overview
A short arc lamp does not start at its running voltage. The lamp runs at 12 to 25 V once the arc is lit, but the gas has to be broken down first, and that takes a pulse of 17 to 35 kV at the lamp. The igniter is the circuit that makes that pulse, and it has to stop working the moment the arc forms, because the same high voltage across a lit lamp destroys it.
That is why the igniter is nearly always quoted with the supply rather than on its own. The supply charges the boost capacitor, the igniter discharges it through a step up transformer and a spark gap, and both share the sense circuit that decides when to stop pulsing. Splitting the two across different makers means matching the boost voltage, the pulse width and the shutoff threshold, which is a great deal of work to save a small amount of money.
The supplies on this page carry the igniter inside the enclosure. They accept 100 to 240 V AC, deliver 100 to 300 W in constant power mode, and pulse at plus 15 kV nominal until the lamp lights or a six second timer ends the attempt. Xenon and mercury versions differ in output voltage and current, so the lamp type decides the model before anything else.
Key Specifications
| Parameter | Value | Notes |
|---|---|---|
| Output power | 100 to 300 W, constant power | Potentiometer adjustable |
| Igniter output | Plus 15 kV nominal, plus or minus 3 kV | Bilateral pulse |
| Boost voltage before ignition | Above 110 V | Falls to the running voltage after the arc forms |
| Strike rate | 4 strikes per second minimum | Plus or minus 2 |
| Ignition timer | 6 plus or minus 1 s of pulses | Can be disabled by jumper |
| Igniter life | More than 80,000 strikes | Per supply |
| Output current, xenon | 9 to 22 A DC | Running voltage 10 to 25 V |
| Output current, mercury | 4 to 10 A DC | Running voltage 10 to 40 V |
| Output ripple | Under 5 percent at 300 W | Measured DC to 20 MHz |
| Line input | 100 to 240 V AC, 50 to 60 Hz | 5.3 A rms maximum |
| Trigger needed at the lamp | 17 to 35 kV for Cermax lamps | Pulse 20 ns to 1 us |
| Ground leakage options | Under 300 uA, under 30 uA, under 100 uA | Model letter sets the leakage |
Included Models and Order Codes
The part number carries the lamp type and the ground leakage. The letter before XE or HG sets the leakage: A is under 300 uA, B is under 30 uA and C is under 100 uA. XE models run xenon short arc lamps, HG models run mercury arc lamps, and the fixed power code sets the output the potentiometer is trimmed to at the ends of its travel. CE300BXE is the older 300 W xenon supply, kept on the page because it is still fitted in installed instruments.
| Part Number | Lamp Type | Output Power | Output Current | Ground Leakage | Igniter | Use |
|---|---|---|---|---|---|---|
| CEP301AXE | Xenon, Cermax | 100 to 300 W | 9 to 22 A | Under 300 uA | Plus 15 kV, 6 s timer | General xenon lamps |
| CEP301BXE | Xenon, Cermax | 100 to 300 W | 9 to 22 A | Under 30 uA | Plus 15 kV, 6 s timer | Low leakage, patient contact |
| CEP301CXE | Xenon, Cermax | 100 to 300 W | 9 to 22 A | Under 100 uA | Plus 15 kV, 6 s timer | Hospital equipment |
| CEP301AHG | Mercury arc | 100 to 300 W | 4 to 10 A | Under 300 uA | Plus 15 kV, 6 s timer | Mercury lamp retrofits |
| CEP301BHG | Mercury arc | 100 to 300 W | 4 to 10 A | Under 30 uA | Plus 15 kV, 6 s timer | Low leakage mercury |
| CEP301CHG | Mercury arc | 100 to 300 W | 4 to 10 A | Under 100 uA | Plus 15 kV, 6 s timer | Fluorescence excitation |
| CE300BXE | Xenon, XBO and Cermax | 270 to 315 W | 17 to 22 A | Under 100 uA | Plus 15 kV | Installed instrument replacement |
Key Features
Igniter inside the supply – the boost, the pulse and the shutoff are one circuit, so there is nothing to match between makers
Leakage class in the part number – under 300, 30 or 100 uA, which decides whether the unit can sit near a patient connection
Six second ignition timer – the pulses stop if the lamp does not light, instead of running until something fails
Constant power output – lamp ageing changes the voltage, and the supply holds the power so the light output stays steady
Both lamp chemistries – xenon and mercury versions share the case and the igniter, which keeps spares simple
Auxiliary rails included – isolated 5 V and 12 V outputs for fans and CMOS logic inside the same enclosure
Applications
The supply is chosen with the lamp, the reflector and the housing, and the ignition behaviour is what ties the three together.
Medical and industrial illuminators – a 300 W xenon lamp behind a fibre bundle, with the leakage class set by the endoscope or microscope it feeds
Spectroscopy and fluorescence – a xenon or mercury lamp with a stabilised supply, where light output stability sets the baseline noise
Retrofit of an installed instrument – a drop in supply for a lamp that is still available, keeping the ignition behaviour the optical path expects
Lamp supplies are quoted with the SUPERB PCB and SUPERB PCBA boards that sequence the shutter and read the lamp current, so ignition and control are tested together.
Sourcing and Cross-Reference
The number that a retrofit hinges on is the minimum ignition voltage at the lamp, not the open circuit pulse. A Cermax lamp may break down at 7 to 10 kV on a DC basis, yet need a 13 kV pulse with a 250 ns width, and the maker recommends a target of 17 to 35 kV to cover the whole life of the lamp. A supply with a 15 kV igniter is therefore normal for a lamp that lights at 8 kV, and that margin is what the hot restrike needs.
Hot restrike is the second point. A lamp that has just been switched off needs a higher voltage for about a minute, because the gas is still hot and the density is low. A supply that ignites reliably from cold and fails a minute after a restart is not faulty; it is running out of margin. Extra trigger voltage and a clean, short lamp lead are the two fixes.
Lead length and routing matter more than the datasheet suggests. The trigger pulse is fast, and a long lead between the igniter and the lamp behaves as a capacitor that shunts part of the pulse. Keeping that run under about a metre, away from signal wiring, and using the maker lead where one is offered, solves most field ignition problems before they appear.
Supply, igniter lead and lamp connector are kitted through SUPERB Assembly against the instrument wiring drawing.
Q: Can you supply a 300 W xenon supply with a built in igniter, plus 15 kV output and an under 30 uA leakage class?
A: Yes. SUPERB Tech quotes the supply against the lamp type, the leakage class and the ignition voltage at the lamp, and states the recommended lead length.
Why Choose SUPERB for Arc Lamp Igniters and Power Supplies
- Igniter and supply as one unit: boost, pulse and shutoff matched by the maker, with no field matching needed
- Leakage class visible: the part number states the ground leakage, which is the first question in medical equipment
- Both lamp chemistries: xenon and mercury versions on one page, with the output current for each
- Installation guidance included: lead length, hot restrike and trigger margin written out beside the part numbers
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Xenon and Deuterium Lamps, Lamp Housings and Shutters, Lamp Reflectors and Ellipsoidal Condensers, Wavelength Calibration Lamps, Fiber Bundles and Light Guides, PWM Controller ICs for Switching Supplies.