Contact Us

MAX11410ATI+T

Brand: Analog Devices
Analog Devices MAX11410ATI+T is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

MAX11410ATI+T — Analog & Mixed-Signal ICs | Superb Automation

MAX11410ATI+T

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The MAX11410ATI+T from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

MAX11410ATI+T: 24 bits of resolution and 3 ppm of linearity

The MAX11410ATI+T is a 24-bit delta-sigma converter with ten analog inputs, a programmable gain amplifier from 1 to 128, and a 1.9 ksample per second maximum rate, in a 28-pin 4 mm by 4 mm TQFN. It runs from 2.7 V to 3.6 V analog and 1.7 V to 3.6 V on the digital side, has simultaneous 50 Hz and 60 Hz rejection of 90 dB, specifies 3 ppm typical integral nonlinearity with no missing codes, offers on-demand offset and gain self-calibration, and covers -40 C to +125 C. It sits in the analog and mixed-signal IC line card with the precision converter range.

Resolution, linearity and noise are three different numbers

With a 2.5 V reference the least significant bit at a gain of 1 is 149 nV. At a gain of 128 it is 1.16 nV, which is below the noise of any front end that would be connected to it, so the high gain settings are there to fit a small signal into the converter range, not to buy extra bits. The linearity figure is the one that limits absolute accuracy:

QuantityFigureIn 24-bit codes at 2.5 V
Resolution24 bits149 nV per code at gain 1
Integral nonlinearity3 ppm typical7.5 uV, about 50 codes
Mains rejection90 dB at 50 Hz and 60 Hz1 V of mains becomes 31.6 uV
Conversion time1.9 ksample per second526 us per conversion
Channel scanten inputs, one converter5.26 ms for a full round
Referencetwo dedicated, one shared differential inputratiometric or absolute
Analog supply2.7 V to 3.6 V3.3 V nominal

Fifty codes of nonlinearity against 24 bits of resolution is the usual gap in this class: the converter can resolve 149 nV steps but it does not stay on a straight line to that level, so a 20-bit absolute measurement needs a calibration against a known input. The self-calibration command removes offset and gain error in the signal chain, not the integral nonlinearity of the converter itself.

Rate, channel count and what 90 dB applies to

There is one converter behind ten inputs, so the ten channels are scanned in sequence. At the full 1.9 ksample per second each conversion takes 526 us and a full round takes 5.26 ms, which is about 190 complete scans per second. A product that needs ten channels at 1 ksample each needs two devices, not one.

The 90 dB rejection is a property of the digital filter at the rates where it rejects both line frequencies at once, which is where the output data rate is a submultiple of both 50 Hz and 60 Hz. At the top of the rate range the filter is shorter and the rejection falls, so a product that runs at 1.9 ksample per second should not assume 90 dB. The datasheet's filter table is the place to confirm the figure at the chosen rate.

Selection notes

  • The inputs can be single ended or fully differential in any combination, so a mixture of a bridge and several single-ended housekeeping signals can share one part.
  • The input buffers isolate the signal from the switched capacitor input, which is what allows a high impedance sensor to connect without an external amplifier, but the buffer offset and drift become part of the error budget.
  • Two dedicated and one shared differential reference inputs allow a ratiometric bridge measurement and an absolute reference to coexist.
  • The internal oscillator removes the need for a crystal; an external clock is the option when several converters have to be synchronised.

Questions buyers ask

Is 24 bits usable at the full rate? Not at 24 bits of accuracy. The resolution is 24 bits at any rate, but the noise rises with the rate, so the number of usable bits at 1.9 ksample per second is set by the noise table and is lower than the 24-bit resolution figure.

Can it measure a thermocouple directly? With a high gain setting and a cold junction reference, yes, but the bias current and the input filtering have to be checked against the source impedance. The medical and instrumentation component range covers the reference and the front end parts that usually sit around it.

What should a quote request include? The order code, the reference voltage and type, the number of channels and the rate per channel, and the sensor impedance. Send the BOM line to the converter cross reference for a second source or a pin-compatible alternative at the same rate.

Request Quote — In Stock, 100% New & Original, Full Warranty