LTM8078EY#PBF
Product Specifications
LTM8078EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8078EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8078EY: the same dual 1.4 A module with a 0 degree floor, and who that fits
The LTM8078EY#PBF is the commercial grade member of the same 40 V dual step-down module: 1.4 A per channel, 2.8 A paralleled, 0.8 V to 10 V out from 3 V to 40 V in, in a 6.25 mm square BGA. The difference from the I grade is one line in the guarantee: the E grade is specified from 0 to +125 degrees internal rather than from -40, so every limit in the electrical table, including the 784 mV to 816 mV feedback window over temperature, is promised only above freezing. For equipment that never sees a cold start, that is the part with the shorter qualification paper trail and usually the better availability.
Published values
| Parameter | Value |
|---|---|
| Input range | 3 V to 40 V on VIN1, VIN2 from 2 V with VIN1 at 3 V |
| Output range | 0.8 V to 10 V per channel |
| Continuous current | 1.4 A per channel at 24 V in, 3.3 V out, 85 degree ambient |
| Current limit | 2.5 A maximum output DC current per channel |
| Switching frequency | 300 kHz to 3 MHz, one resistor per setting |
| Feedback voltage | 800 mV nominal, 792 mV to 808 mV at 25 degrees |
| Guaranteed range | 0 to +125 degrees internal, TJ maximum 125 degrees |
| Shutdown current | 2 mA typical, 4 mA maximum |
| No load current | 60 mA with SYNC low, 10 mA with SYNC at 3.3 V |
| Line and load regulation | 0.1 percent and 0.2 percent |
| Output ripple | 10 mV RMS at 3.3 V out |
| Package | 49 ball BGA, 6.25 mm by 6.25 mm by 2.22 mm, MSL 3 |
| Thermal | 31.3 degrees per watt junction to ambient, 10.6 to the board |
| Finish | SAC305, RoHS, tin lead version available under the same device code |
The 0 degree line is a specification boundary, not a storage limit
Storage is a separate rating, -55 to +125 degrees, so a module that spends a winter in an unheated warehouse is fine. What the E grade does not promise is behaviour while the part is operating below 0 degrees. Startup at -10 degrees, the point where a lot of outdoor and vehicle equipment is actually turned on, is outside the guaranteed window even though the module will usually start.
The practical test is simple: write down the lowest ambient the product is specified to operate at. If that number is 0 or above, the E grade is fully specified for the job and the I grade adds cost and lead time for a margin no test will ever exercise. If the number is negative, the E grade puts a gap between the specification and the paperwork that has to be closed by test data from the vendor, which is a longer conversation than a part number change.
Availability is usually the reason this code is on the line
Two grades of the same module rarely ship in the same quantity. When the I grade is on allocation, the E grade is often on the shelf, and for an indoor industrial product the substitution is legitimate as long as the cold start question above is answered and the drawing is updated with the new order code. The device marking is identical between the two, so the only place the grade shows is the reel label and the order line.
That is also the failure mode to watch on an assembly line: an E grade pulled against a drawing that says I grade cannot be caught by looking at the part. Mark the grade on the assembly drawing and on the incoming inspection record, not just on the BOM comment field.
Efficiency and thermals do not move with the grade
The 40 degree rise from an 85 degree ambient to a 125 degree junction is set by the 31.3 degrees per watt figure, and it applies to both grades. Two channels at 1.4 A and 3.3 V is 9.24 W out, 1.28 W of allowed loss, and therefore 87.8 percent efficiency per channel in still air. A 5 V output at the same current needs 91.6 percent, which is a different operating point entirely.
If the board has airflow, the number moves in the right direction and the same module will carry more. If the board is in a sealed enclosure with no fan, plan for the 3.3 V case and treat anything above it as a derated condition that has to be measured on the actual assembly.
Sourcing notes for this family: component lead time solutions holds the cross references, the power management cross reference is the pre substitution check, and how to verify a drop in replacement is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask about the E grade
Can an E grade replace an I grade on an existing board? Electrically yes, the die and the package are the same. Contractually the cold start guarantee is lost. If the drawing says I grade and the product is specified below 0 degrees, the change needs an engineering sign off and a note in the build record.
Does the E grade have the same automotive option? No. The AEC-Q104 grade 2 flow, the IY#3PP order code, exists on the I grade only, because the qualification has to be run over the full -40 degree window. An automotive build cannot use the E grade with a paper waiver.