Contact Us

LTM8067IY#PBF

Brand: Analog Devices
Analog Devices LTM8067IY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8067IY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8067IY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8067IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8067IY: a 2 kVAC isolated flyback that fits a 48 V sum rule

The LTM8067IY#PBF is a 2 kVAC isolated flyback module with the controller, the switches and the transformer inside an 11.25 mm by 9 mm by 4.92 mm package. It takes 3 V to 40 V in and produces an adjustable 2.5 V to 24 V out, up to 450 mA at 24 V in and 5 V out, with the output voltage set by one resistor. The part is UL60950 recognised under file 464570, and the isolation rating is a 2 kVAC test applied for one second, equivalent to 2.83 kVDC. The industrial grade guarantees the table from -40 to +125 degrees internal.

Published values

ParameterValue
Input range3 V to 40 V
Output range2.5 V to 24 V, set by RADJ: 15.4k for 2.5 V, 8.25k for 5 V, 1.78k for 24 V
Output currentup to 450 mA at 24 V in and 5 V out
Isolation2 kVAC for one second, 2.83 kVDC equivalent, UL60950 file 464570
Absolute maximumVIN plus VOUT of 48 V in total, VOUT relative to VOUTN 25 V
5 V set point tolerance4.75 V to 5.25 V
Line and load regulation1 percent each
Output ripple30 mV RMS at 100 mA, 1 MHz measurement bandwidth
Quiescent current3 microamps with RUN at 0 V, 7 mA not switching
RUN threshold1.214 V falling typical, 1.18 V to 1.25 V guaranteed, 2.5 microamps of pin current
Output short circuit80 mA of input current with the output shorted
Package38 pin BGA, 11.25 mm by 9 mm by 4.92 mm, 1.1 g
Thermal20.8 degrees per watt to ambient, 5.1 to the board, 18.4 to the top
Temperature grade-40 to +125 degrees internal
Reinforced isolationnot claimed: the 2 kVAC is a component test, board spacing still sets the system rating

The 48 V sum rule decides the usable combination

VIN plus VOUT is limited to 48 V, and that is measured as (VIN - GND) plus (VOUT - VOUTN). A 24 V input with a 5 V output is 29 V and comfortable. A 40 V input with a 12 V output is 52 V and outside the rating, even though 40 V in and 12 V out each look fine on their own. The highest output at a 40 V input is 8 V.

The same rule explains why the current curve falls as the input rises. At 450 mA and 5 V the output is 2.25 W, and a flyback at 70 to 75 percent efficiency draws a bit over 3 W from the input, which at 24 V is 130 mA and at 40 V is 80 mA. The reflected voltage plus the leakage spike is what the internal switch sees, so the sum rule is protecting the switch, not the transformer insulation.

What the isolation number does and does not cover

The 2 kVAC figure is a one second withstand test on the component. It says the barrier survives a hipot test, not that the assembly is a reinforced isolation system. Creepage and clearance on the board, the transformer's own insulation system and the pollution degree of the enclosure all sit outside the module and all have to be assessed for the end product's standard.

The other half of the isolation story is the return path. VOUTN is not ground, and tying it to the primary ground defeats the barrier. Anything that crosses the barrier, including the feedback network, has to be inside the module or opto isolated outside it, and that is why the output voltage is set by a single resistor referenced to the isolated side.

Where a flyback module is the right answer

Gate drive for an IGBT or a high side switch is the classic case: the driver needs a floating supply that follows the emitter, and a module with a transformer already inside saves the engineer from specifying one. Industrial sensor loops and isolated communication ports are the others, both for the barrier and for the fact that a module passes emissions and immunity as a tested block.

The output regulation of 1 percent line and load is looser than a post regulated rail, and 30 mV RMS of ripple is on the high side for an analogue supply. Where the load needs better than that, the same family offers a version with an LDO after the flyback, and that is the part to reach for before adding a discrete post regulator.

For a board that has to keep running while a reel runs out, the power management cross reference is where the family alternatives sit, BOM shortage recovery is the check list before a substitute goes in, and the pin to pin cross reference is how a gap is covered without a new line item.

Two questions buyers ask about the isolated module

Can the module be used for a 24 V output from a 24 V input? No, the sum would be 48 V at the absolute maximum with no margin, and the module is a flyback, so a 1:1 ratio already runs at the worst duty cycle. A 24 V output needs an input of 12 V or lower to stay inside the rule with margin.

Is the isolated output regulated well enough for an ADC reference? Not directly. One percent line and load regulation and 30 mV RMS of ripple are fine for gate drive and for a sensor loop, but an analogue rail wants the post regulated version or a following LDO. Size the LDO dissipation from the flyback output minus the load voltage.