Contact Us

LTM8063EY#PBF

Brand: Analog Devices
Analog Devices LTM8063EY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8063EY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8063EY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8063EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8063EY: the 2 A, 15 V module for controlled ambients

The LTM8063EY#PBF is the commercial grade of the 40 V, 2 A step-down module: 0.8 V to 15 V out, 200 kHz to 2.2 MHz, 6.25 mm by 4 mm by 2.22 mm, 41.5 degrees per watt. The table is the industrial table with the guarantee starting at 0 degrees. It is the code to use in test instruments, bench supplies, laboratory equipment and any mains powered product whose specification begins at 5 or 10 degrees, where the industrial cold start window would never be exercised and the availability of the commercial code is the practical argument.

Published values

ParameterValue
Input range3.2 V to 40 V
Output range0.8 V to 15 V
Continuous current2 A at 12 V in, 5 V out
Peak current2.5 A
Feedback voltage774 mV nominal
Switching frequency200 kHz to 2.2 MHz
Guaranteed range0 to +125 degrees internal
Shutdown current3 microamps
No load current8 microamps not switching
Output ripple15 mV at 2 A
Power good window0.84 V falling, 0.70 V rising
Package6.25 mm by 4 mm by 2.22 mm BGA, 0.14 g
Thermal41.5 degrees per watt to ambient, 13 to the board
Configurationsstep-down, or inverting for a negative rail

A 2 A module that is really a 1.5 A module at 5 V and 85 degrees

The thermal budget is 0.96 W. At 5 V and 2 A that leaves 91.2 percent of efficiency to hold a 125 degree junction, which is achievable but leaves nothing for a hot enclosure. Run the same rail at 1.5 A and the loss budget per watt of output improves by a quarter, which is the difference between a build that works in an oven test and one that shuts down.

The published 2 A is honest, it simply has an ambient attached. Anything shipping into a sealed box should be measured at the real internal temperature rather than assumed from the room.

Where the 15 V ceiling comes from

The internal inductor and the switch rating set the top of the output range, and at 15 V out the duty cycle from a 24 V input is 62 percent, which is comfortable, while from 40 V it is 37 percent and the minimum on time starts to matter at 2.2 MHz. That is why the data sheet adds the note about switching frequency at high input voltage.

If a rail needs 15 V at 2 A, the honest configuration is a lower input voltage or a lower switching frequency, not a higher current part. Moving to the 2.5 A module buys current, not duty cycle.

Grade and end of life

The E and I codes share a die, a package and a reel. When the industrial code is short, the commercial code can carry a build of indoor equipment after the temperature note on the drawing is updated. That decision belongs with the product's specification, not with purchasing.

If the product is a long life instrument, check the vendor's lifecycle status before freezing the order code, because a change of status on one grade does not always happen at the same time as on the other. A last time buy on the E grade while the I grade continues is a normal pattern.

Two pages worth reading before a purchase order goes out are component lead time solutions and the power management cross reference; the first lists what else fits the socket, the second is the test sequence for a drop in, and vendor consolidation covers the case where the shortage is already on the line.

Two questions buyers ask about this code

Does the E grade run at the same switching frequency range? Yes, 200 kHz to 2.2 MHz on both codes, with the same resistor values for each point. The frequency is a property of the die.

Is the inverting configuration available on the E grade? Yes. Configuration is a matter of how the pins are wired, not of the temperature grade. The same level shift and input current considerations apply.