LTM8057EY#PBF
Product Specifications
LTM8057EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8057EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTM8057EY#PBF: An Isolated 1 W DC to DC Module in a 9 mm by 11 mm Body
What this part is
The LTM8057 is an isolated DC to DC converter built as a module: the transformer, the switching stage and the control loop are inside one package, and what is left outside is the input and output capacitance. The input range is 3.1 V to 31 V, the output is adjustable from 2.5 V to 12 V, and the isolation is rated at 2 kV AC with a 3 kVDC test, under a UL60950 recognition. The body is a 9 mm by 11.25 mm by 4.92 mm BGA, which is what makes the part interesting in a channel that has no room for a discrete flyback.
It is a current mode converter with programmable soft start and a user configurable undervoltage lockout, and it delivers up to 440 mA at 24 V in and 2.5 V out. The demo board for the family runs 4.5 V to 29 V in and 5 V at 350 mA out, which is the more realistic operating point for a field interface supply.
Published figures that matter to a buyer
| Function | isolated DC to DC module, flyback |
| Input range | 3.1 V to 31 V |
| Output range | 2.5 V to 12 V, adjustable |
| Output current | up to 440 mA at 24 V in and 2.5 V out |
| Isolation | 2 kV AC, tested at 3 kVDC |
| Recognition | UL60950, file 464570 |
| Control | current mode, programmable soft start |
| Lockout | user configurable undervoltage lockout |
| Body | BGA, 9 mm by 11.25 mm by 4.92 mm |
| Demo board | 4.5 V to 29 V in, 5 V at 350 mA out |
Where the headline numbers stop
The 440 mA figure belongs to one operating point. At 2.5 V out it is 1.10 W of output, and at 75 percent efficiency that is 1.47 W drawn from the 24 V rail, or 61 mA of input. Move the output to 12 V and the same body would be asked for 5.28 W, which is five times the power of the quoted point and is not what the 440 mA describes: at 12 V out and 80 percent efficiency the input would be 6.6 W, or 275 mA from 24 V, and whether the module can carry that depends on the ratio and the thermal path rather than on the current number alone.
The isolation figure needs the same care. Two kilovolts AC is 2,828 V peak and it is a one minute withstand test, and the vendor also states a 3 kVDC test; neither of those is a continuous working voltage. The working voltage of the barrier belongs to the isolation system and to the pollution degree of the application, and it has to be taken from the data sheet isolation tables rather than from the headline. A product that treats 2 kV AC as a working rating has no margin.
The input range of 3.1 V to 31 V is a ten to one span, which is what makes the part usable on a 12 V or a 24 V rail with the same order code, but the minimum start voltage and the lockout are two different things: the lockout is set by the user and the 3.1 V floor is the point below which the converter will not run regardless.
Applications where it fits
- Isolated field interfaces for RS485, CAN and industrial IO modules.
- Gate drive and bias supplies where the reference node has to be separated from the control ground.
- Medical and laboratory instruments that need a barrier between a patient connected front end and the digital side.
- Telecom line cards running from a 24 V or 48 V derived rail where a small isolated housekeeping supply is needed.
Two questions buyers ask
Does the module need an external transformer? No, the transformer is inside the package. That is the point of the part and it is also why the isolation rating belongs to the module rather than to a component the buyer selects. What is external is the input and output capacitance and the parts that set the output voltage and the lockout.
Can it be used at 12 V out and full current? The quoted current is a statement about one ratio. A 12 V output from a 24 V input is a 50 percent duty point and the losses and the thermal rise both change, so the current has to be read off the curves for that ratio. A buyer who needs 5 W at 12 V should be looking at the larger members of the family rather than at a derating of this one.
Sourcing notes and next step
LTM8057EY#PBF is the BGA body in a tray, and the E and Y fields in the code carry the temperature grade and the packing, so a cross reference has to match them. Module order codes in this family also differ in output voltage setting and in the presence of a lead frame, and a substitute with a different suffix is a different part. The power management cross reference page sets out the comparison fields for a supply substitution, the BOM shortage recovery page covers the route when the module is quoted long, and the analog and mixed signal IC family page lists the rest of the power line.
Request Quote — In Stock, 100% New & Original, Full Warranty