Contact Us

LTM8047MPY#PBF

Brand: Analog Devices
Analog Devices LTM8047MPY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8047MPY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8047MPY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8047MPY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8047MPY: the isolated flyback module screened to start at minus fifty five

The LTM8047MPY#PBF is the wide temperature code of the 725 VDC isolated flyback module: 3.1 V to 32 V in, 2.5 V to 12 V out at up to 440 mA, in the same 11.25 mm by 9 mm by 4.92 mm ball grid array. Its guaranteed limits run from -55 to +125 degrees internal, which is the code to specify when the equipment has to be specified to start in an unheated enclosure, on a mast or in a vehicle at the cold extreme. Everything else, including the 20 mV RMS ripple and the 3.1 V minimum BIAS, is shared with the industrial code.

Published values

ParameterValue
Input range3.1 V to 32 V; 32 V absolute maximum on VIN, RUN and BIAS
Isolation725 VDC, one second in each polarity
Output range2.5 V to 12 V, set by one resistor from ADJ
Output currentup to 440 mA at 2.5 V; 280 mA at 5 V from a 15 V input in the typical circuit
Guaranteed range-55 to +125 degrees internal
Quiescent current850 microamps not switching, 1 microamp shut down
Output ripple20 mV RMS at 0.1 A
Load regulation1.5 percent from 0.05 A to 0.2 A
Line regulation1.7 percent from 6 V to 31 V
Short circuit current30 mA into a shorted output
BIAS3.1 V minimum, 8 mA at 12 V in with 100 mA of load
Thermal16 degrees per watt to ambient, 4.1 to the board, 4 to the board junction
Package45 lead BGA, 11.25 mm by 9 mm by 4.92 mm, MSL 3, 1.1 g
Constraintthe sum of the input and output voltages is held to 36 V

What minus fifty five degrees buys on a real product

A cold start is a different test from a cold storage. At -55 degrees the electrolytic capacitors on the input have almost no capacitance, the flyback transformer barely starts, and a controller that is only characterised to zero will either skip the first cycles or fail to start at all. The MP code is the one with guarantees at that corner, so the start-up behaviour is specified rather than hoped for.

The other half of the cold story is warm-up. A module that starts at -55 has to survive the thermal ramp as its own dissipation brings it up, and the 16 degrees per watt path is what sets how fast that happens. On a small load the part may sit cold for minutes, so the soft start capacitor and the RUN divider have to be chosen for the cold end, not only for the room.

The forty five volt sum is the constraint that catches people

The absolute maximum table holds the sum of the input voltage and the output voltage to 36 V, and the output relative to its own return to 16 V. On a 24 V input that leaves 12 V of output, which is exactly the top of the range, and on a 32 V input it leaves 4 V. A build that wants 28 V in and 5 V out is inside both numbers; a build that wants 30 V in and 10 V out is not, even though each number on its own looks legal.

The second number, the 16 V output ceiling relative to the isolated return, applies regardless of input. It is the transformer and the secondary diode that set it, so a rail above 12 V is a different part, not a different resistor.

Heat, and the reason the BIAS pin exists

At 16 degrees per watt and an 85 degree ambient the module has 2.5 W of dissipation available before the junction reaches 125 degrees. A 5 V rail at 280 mA is 1.4 W out, which at 80 percent efficiency is 0.35 W of loss, so the number that limits this part is not the thermal path but the transformer ratio and the input current. That is why the current curve falls with output voltage rather than staying flat.

Tying BIAS to a 5 V rail instead of the input moves the internal housekeeping current out of the input and cuts dissipation, which matters most at a 24 V or 32 V input where the switch has the widest swing. The pin needs 3.1 V minimum and draws 8 mA at 12 V in with 100 mA of load, so the bias rail has to be able to supply that before the main output is up.

When an order code in this family cannot be found, defense grade components lists what else does the same job, the power management cross reference covers what to check before a part is dropped into an existing board, and component obsolescence management is the route we take on a live shortage.

Two questions buyers ask about the MP code

Is the MP grade a different part number from the industrial code? Yes, LTM8047MPY#PBF against LTM8047IY#PBF, and the MP code also exists in tin lead as LTM8047MPY. The die and the package are the same; the screened temperature window and the test coverage are not.

Can the module drive a load that is referenced to the primary ground? No. The output floats on the secondary side of a 725 VDC barrier, and tying either output terminal back to the primary ground defeats the isolation and puts the barrier in parallel with a wire.