LTM8047IY#PBF
Product Specifications
LTM8047IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8047IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8047IY: a 725 V isolated flyback for sensor loops and split grounds
The LTM8047IY#PBF is the industrial code of the 725 VDC isolated flyback module, guaranteed over -40 to +125 degrees internal. It takes 3.1 V to 32 V in and produces 2.5 V to 12 V at up to 440 mA from a single resistor, with the switching controller, the switches and the transformer inside an 11.25 mm by 9 mm by 4.92 mm package that weighs 1.1 g. What it does in a system is break a ground path: the output floats on the far side of the barrier, so a sensor at the end of a long cable and the acquisition card that reads it no longer share a return carrying motor or solenoid current.
Published values
| Parameter | Value |
|---|---|
| Input range | 3.1 V to 32 V |
| Isolation | 725 VDC, tested one second in each polarity |
| Output range | 2.5 V to 12 V, one resistor from ADJ |
| Output current | 440 mA at 2.5 V; the curve falls with output voltage |
| Guaranteed range | -40 to +125 degrees internal |
| Line and load regulation | 1.7 percent and 1.5 percent |
| Output ripple | 20 mV RMS at 0.1 A |
| Quiescent current | 850 microamps not switching, 1 microamp shut down |
| RUN threshold | 1.24 V rising typical, 2.5 microamps of pin current |
| BIAS | 3.1 V minimum, 8 mA at 12 V in with 100 mA of load |
| Thermal | 16 degrees per watt to ambient, 4.1 to the board |
| Package | 45 lead BGA, 11.25 mm by 9 mm by 4.92 mm, MSL 3, 1.1 g |
| Constraint | input plus output held to 36 V |
What a barrier does for a millivolt signal
A four to twenty milliamp loop or a bridge sensor puts a few millivolts at the input of an amplifier. If the sensor ground and the card ground are joined by a cable return that also carries a solenoid or a motor, the voltage across that return appears in series with the signal. An isolated supply removes the shared return from the supply side, and the measurement stops moving when a relay in the next cabinet closes.
The barrier is rated 725 VDC as a one second withstand test in each polarity, which answers the fault question. The continuous voltage between the two grounds is a different number and comes from the installation, so the two questions have to be asked separately before an isolated module is chosen for a high side shunt or a mains referenced front end.
Sizing the rail from the curve, not from the headline
The 440 mA figure belongs to a 2.5 V output. In the typical circuit a 5 V rail from a 15 V input delivers 280 mA, and the curve in the data sheet falls further as the output rises because the flyback has to move the same energy through a longer duty cycle. Quoting 440 mA for a 12 V rail is the mistake that shows up as a rail that will not start into its load.
The input side has the same shape. A 24 V to 5 V conversion at 280 mA is 1.4 W, and at 80 percent efficiency the input current is about 73 mA, small enough that a 22 microfarad input capacitor and a modest BIAS tie are all the input needs. A 3.3 V input at the same output power draws more than five times that current, and the input capacitor and the RUN divider have to be sized for the low line case.
The parts that are not optional
A bypass capacitor on the BIAS pin, an input capacitor close to the VIN bank, and an output capacitor sized for the ripple current are the three that decide whether the module behaves. The soft start pin sets how fast the output comes up, which matters when the load has a large capacitance and the input supply has a current limit. The RUN pin has a precise 1.24 V threshold and pulls 2.5 microamps, so an undervoltage lockout divider is a two resistor calculation rather than an approximation.
The isolated return is the fourth. It has to be a real net with its own copper, and it must not be stitched to the primary ground anywhere on the board, including through a mounting hole or a shield can. That single connection is the most common way an isolated supply quietly stops being isolated.
Sourcing notes for this family: the power management cross reference holds the cross references, medical device components is the pre substitution check, and how to verify a drop in replacement is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask about the isolated rail
Can two of these make a bipolar isolated rail? Yes, two modules with their secondaries arranged as plus and minus around the isolated return give a bipolar supply, and the barrier is then common to both. Each module needs its own input capacitor and its own RUN divider.
Does the output need a minimum load? The module runs at no load, with 850 microamps of quiescent current while not switching. A very light load will see the switching ripple dominate, so an application that needs a quiet rail at microamp loads should add a small preload.