Contact Us

LTM8047EY#PBF

Brand: Analog Devices
Analog Devices LTM8047EY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8047EY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8047EY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8047EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8047EY: the isolated flyback for a cabinet that never goes below freezing

The LTM8047EY#PBF is the commercial grade of the 725 VDC isolated flyback module. Input range is 3.1 V to 32 V, output is 2.5 V to 12 V at up to 440 mA from one resistor, and the whole converter including the transformer sits in an 11.25 mm by 9 mm by 4.92 mm ball grid array. Its limits are guaranteed from 0 to +125 degrees internal, with the behaviour down to -40 assured by characterisation, which fits an industrial switch, a rack instrument or a floor mounted controller that is only ever powered up in a building.

Published values

ParameterValue
Input range3.1 V to 32 V
Isolation725 VDC, one second in each polarity
Output range2.5 V to 12 V, one resistor
Output currentup to 440 mA at 2.5 V
Guaranteed range0 to +125 degrees internal
Line and load regulation1.7 percent and 1.5 percent
Output ripple20 mV RMS at 0.1 A
Quiescent current850 microamps not switching, 1 microamp shut down
BIAS3.1 V minimum, 8 mA at 12 V in
Thermal16 degrees per watt to ambient, 4.1 to the board, 15 to the top
Package45 lead BGA, 11.25 mm by 9 mm by 4.92 mm, MSL 3, 1.1 g
Constraintinput plus output held to 36 V; output held to 16 V relative to the isolated return
FinishSAC305 as standard; the industrial and MP codes also come in tin lead

The grade question, answered from the product specification

The difference between this code and the industrial one is one sentence of the specification. Below 0 degrees the E grade is characterised and correlated, not guaranteed, so a product that is specified to start at minus 5 is asking for something the data sheet does not promise. Nothing in the part changes at the freezing point, and in practice it will usually start, which is exactly why the gap is dangerous: a prototype that starts in the cold does not prove a production population will.

The test for the right code is one line in the product requirement. Lowest operating ambient at or above zero means this code is fully specified and the industrial code buys cost and lead time for a margin no test will exercise. Below zero means the industrial code or a written statement from the vendor.

Why a commercial grade is often the one on the shelf

Modules at the wide temperature extremes are built in smaller quantities and screened harder, so the E code is usually the one with stock when a line is short. For an indoor product the substitution is legitimate, provided the drawing is updated and the cold start question is answered in writing. The catch is that the marking is identical, so the reel label is the only record of what was fitted.

Put the grade on the assembly drawing, on the incoming inspection record and in the build file. A substitution that exists only in a purchasing email will be invisible two years later when a service engineer tries to work out why one batch behaves differently in a cold room.

The rail on the far side of the barrier

The output floats, so the isolated return becomes the reference for everything on that side, including the ADC that reads the signal. Keeping that net off the primary ground is what makes the isolation real, and it is the step most often broken by a mounting screw, a shield can or a debug header that was left in place. The barrier is tested at 725 VDC for one second in each polarity, which is a fault withstand figure rather than a continuous working voltage.

Ripple on the output is 20 mV RMS at 0.1 A. That is fine for a digital load and marginal for a 16 bit converter, so a rail that feeds a precision front end either needs a post regulator, which is the LTM8048 in the same family, or a filter built from the output capacitor and a series element.

For a board that has to keep running while a reel runs out, the power management cross reference is where the family alternatives sit, OEM procurement is the check list before a substitute goes in, and component lead time solutions is how a gap is covered without a new line item.

Two questions buyers ask about the E grade

Does this module need an external transformer or diode? No. The transformer, the switches, the controller and the support parts are inside the package. Input, output and bypass capacitors plus the set resistors are the external bill.

Can the output be referenced to the primary ground on purpose? Electrically the output can be tied anywhere, but tying it to the primary ground puts the barrier in parallel with a wire and removes the isolation the part was bought for, as well as loading the transformer with the primary return current.