LTM8045IY#PBF
Product Specifications
LTM8045IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8045IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8045IY: one module that makes a negative rail or a SEPIC rail up to 700 mA
The LTM8045IY#PBF is a single output module configured as a SEPIC or as an inverting converter by grounding the appropriate output rail, in a 11.25 mm by 6.25 mm by 4.92 mm ball grid array that weighs 0.9 g. In the SEPIC arrangement the regulated output can sit above, below or level with the input, which is what makes it usable on a battery rail that starts at 4.2 V and ends below the 3.3 V the load needs. Input range is 2.8 V to 18 V, output spans plus or minus 2.5 V to plus or minus 15 V, current is 700 mA at 2.5 V from a 12 V input and 375 mA at 15 V, and switching runs from 200 kHz to 2 MHz.
Published values
| Parameter | Value |
|---|---|
| Input range | 2.8 V to 18 V, 20 V absolute maximum on VIN and RUN |
| Output range | 2.5 V to 15 V positive, -2.5 V to -15 V negative |
| Output current | 700 mA at plus or minus 2.5 V from 12 V; 375 mA at plus or minus 15 V |
| Switching frequency | 2 MHz with RT at 45.3k, 200 kHz with RT at 464k |
| Feedback reference | 1.215 V on a positive output, 5 mV on a negative output |
| Feedback pin current | 83.3 microamps |
| Line and load regulation | 0.6 percent and 0.2 percent |
| Output ripple | 4 mV RMS at 5 V out and 580 mA, 100 kHz to 4 MHz |
| Quiescent current | 10 mA not switching, 1 microamp shut down |
| Input short circuit current | 200 mA with both output rails at zero |
| Thermal | 28.7 degrees per watt to ambient, 10.5 to the board, 40.3 to the top |
| Package | 40 lead BGA, 11.25 mm by 6.25 mm by 4.92 mm, MSL 3, 0.9 g |
| Temperature | guaranteed over -40 to +125 degrees internal |
SEPIC and inverting are the same parts count, not the same behaviour
Grounding the negative output rail gives a SEPIC, where the output can be above or below the input and the converter runs a continuous input current. Grounding the positive rail instead gives an inverting converter with a negative output and a discontinuous input current that is drawn in pulses from the source. On a battery the SEPIC is usually the better choice for a positive rail and the inverting arrangement is only used when a negative rail is genuinely needed.
The feedback network changes with the arrangement. A positive output is set against 1.215 V with 83.3 microamps flowing out of the feedback pin, while a negative output is set against 5 mV with the same pin current. A divider carried over from the positive case produces a rail that is wrong by more than the resistor tolerance, and the symptom is a supply that will not settle rather than a supply that fails.
Where the 700 mA figure lives, and where it does not
Seven hundred milliamps belongs to a 2.5 V output from a 12 V input. At 15 V the same module is quoted at 375 mA, and the reason is thermal rather than magnetic: 375 mA at 15 V is 5.6 W out, and at an 85 degree ambient the 28.7 degrees per watt path allows 1.39 W of loss, so the module needs 80 percent efficiency to hold that point. At 2.5 V and 700 mA the output is 1.75 W and the floor drops to 56 percent, which the converter clears with room.
The practical reading is that a request for a 15 V rail at half an amp from this part is outside the thermal allowance at an 85 degree ambient, and a request for a 5 V rail at 0.7 A is comfortable. Both are the same order code, which is why the curve matters more than the number on the first page.
The thermal path goes through the board, not the top
The junction to top resistance is 40.3 degrees per watt, against 10.5 to the board. A module in this package therefore cannot be cooled from the lid: the copper under it and the vias through it are the heat path. That is a soldering and copper decision as much as a thermal one, and it is the reason the 4.92 mm height is worth having, since it leaves room for a solid ground plane directly under the part.
On a two layer board with a broken plane the effective resistance is far worse than 28.7 degrees per watt and the current rating quietly disappears. A four layer board with a continuous plane under the module comes close to the published number at the currents quoted here.
Where a customer needs a second position on this part, the power management cross reference is the starting point, how to verify a drop in replacement sets out the checks a substitution has to pass, and OEM procurement is the short lead time route we quote against.
Two questions buyers ask about the inverting module
Can two of these make a plus and minus 5 V supply? Yes, that is the arrangement in the data sheet: one module as a SEPIC for the positive rail and one as inverting for the negative, each with its own feedback divider and its own switching frequency resistor.
What is the minimum input with a 3.3 V output? 2.8 V, and the SEPIC arrangement keeps regulating as the input falls through the output voltage, which is the case a boost or a buck alone cannot cover.