Contact Us

LTM8032EV#PBF

Brand: Analog Devices
Analog Devices LTM8032EV#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8032EV#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8032EV#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8032EV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8032EV: 2 A of quiet 36 V conversion for a product built indoors

The LTM8032EV#PBF is the commercial grade of the 36 V, 2 A step-down module, in the 9 mm by 15 mm by 2.82 mm land grid array with gold pads. Inside is the same converter as the industrial code: 0.8 V to 10 V out, 200 kHz to 2.4 MHz switching, a 790 mV reference, 6 mV RMS of ripple and a radiated emissions performance specified against EN55022 Class B. Its limits are guaranteed from 0 to +125 degrees internal, with the range below freezing assured by characterisation, so it fits a rack unit, a bench instrument or a mains powered controller that is only started in a building.

Published values

ParameterValue
Input range3.6 V to 36 V
Output range0.8 V to 10 V
Output current2 A
Switching frequency200 kHz to 2.4 MHz; 325 kHz with RT at 113k
Reference790 mV at ADJ, 765 mV to 815 mV
Guaranteed range0 to +125 degrees internal
Quiescent current25 microamps not switching, 0.6 microamp shut down
Output ripple6 mV RMS at 2 A
Line and load regulation0.1 percent and 0.3 percent
Auxiliary output100 mA limit from the AUX pin
Thermal25.2 degrees per watt to ambient, 10.3 to the board
Package71 pad LGA, 9 mm by 15 mm by 2.82 mm, MSL 3, 1.2 g

The zero degree line on a board that lives in a cabinet

A cabinet controller is started once, in a building, and then runs continuously. The ambient at the module is higher than the room because the enclosure traps heat, so the 0 to 125 degree window is the one that matters and the E grade covers it. The part is identical to the industrial code above freezing, including the 25.2 degrees per watt thermal path and the 6 mV RMS ripple.

The only question the E grade leaves open is a cold start, which such a product does not have. If the same board is also sold as an outdoor variant with the same artwork, the substitution becomes invisible and dangerous at the same time: the marking is identical, so the only record of which grade was fitted is the reel label and the build file.

What 2 A costs in heat, and where the plane has to be

At an 85 degree ambient the 25.2 degrees per watt path allows 1.59 W of dissipation. Two amps at 3.3 V is 6.6 W out and needs 81 percent efficiency, two amps at 5 V is 10 W out and needs 86 percent, and two amps at 10 V is 20 W out and needs 93 percent. The first two are comfortable; the third is the point where the derating curve decides the answer rather than the headline.

The heat leaves through the pads into the copper, so the plane under the module is part of the electrical bill. A continuous ground plane and a via array under the part meet the published number, while a plane cut by signal traces does not, and a two layer board with a broken plane can lose a third of the rating without any component changing.

Auxiliary rail and start-up behaviour

The AUX pin can source up to 100 mA for small external loads and is not a second regulated output. The BIAS pin needs 1.9 V minimum and 2.8 V for proper operation, and tying it to the output cuts internal dissipation. The RUN/SS pin is both the enable and the soft start, with 5 to 10 microamps of pin current, so one capacitor sets the ramp.

The typical application circuit is marked 7 V to 36 V for start-up while the electrical table gives 3.6 V as the running minimum. That gap is the difference between starting and running, and a 5 V input sits in it: the module will run from 5 V once it is up and will not start from 5 V on its own.

The pages that answer this most often are the power management cross reference for the family alternatives, OEM procurement for the acceptance test, and component lead time solutions for the case where a replacement has to be fitted before the next build.

Two questions buyers ask about the 2 A E grade

Can the E grade be used where the drawing calls for the I grade? Only with an engineering sign off. The parts are identical above freezing, but the cold start guarantee is lost and the marking is the same, so the change has to be recorded rather than assumed.

Does the module need an external inductor or filter? No. The inductor and an input filter are inside the package, and the external bill is bulk input and output capacitance plus the set resistors.