LTM4650EY-1A#PBF
Product Specifications
LTM4650EY-1A#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4650EY-1A#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4650EY-1A#PBF: the E grade of the 50 A module and the six module 300 A rail
The LTM4650EY-1A#PBF is the E grade of the A accuracy dual 25 A or single 50 A module in the 16 mm by 16 mm by 5.01 mm package, with plus or minus 0.8 percent dc error, plus or minus 3 percent transient error against a specified output capacitance, and current sharing across up to six modules for 300 A. The E and I order codes are both listed at minus 40 degree C to 125 degree C, so the grade decision is a guarantee one. The system decision that matters is how many modules the rail needs and how the 300 A is shared.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 4.5 V to 15 V |
| Output voltage | 0.6 V to 1.8 V |
| Output current | dual 25 A or single 50 A per module |
| Maximum shared output | 300 A across six modules |
| DC output error | plus or minus 0.8 percent, A grade |
| Transient output error | plus or minus 3 percent with minimum output capacitance |
| Thermal resistance | 7 degree C per W |
| E grade range | minus 40 degree C to 125 degree C |
| Package | BGA, 16 mm x 16 mm x 5.01 mm |
| Weight | 3.5 g |
| Remote sense | differential amplifier |
| Compensation | external per channel |
Three hundred amps on one rail is six modules and six thermal paths
At 1 V and 300 A the output is 300 W and, at 88 percent, the loss is 41 W spread over six modules, about 6.8 W each. Each module has 7 degree C per W, so each is about 48 degree C above its own local board temperature. That is manageable only if all six see the same copper and the same airflow: a rail built as five modules on a plane and one on a narrow neck runs the sixth hot, and the share loop then pushes current into the cool ones until the hot one cools, which is stable but leaves the rail sitting at the current limit of the majority.
The 300 A figure also belongs to a defined input voltage. From 5 V in, 300 W at 88 percent is 68 A of input current, which is a bus bar rather than a trace, and from 12 V it is 28 A. The input distribution is a separate project on a rail this size, and the module's 15 V maximum input is what keeps the 12 V case inside the part.
Why external compensation is a feature here
Each channel has external compensation, so the loop can be set for the capacitor bank that is fitted rather than for a fixed internal value. That is what allows the plus or minus 3 percent transient claim to be met with a smaller bank, and it is also what makes the part unsuitable for a build without the tools to set it: the compensation network is part of the specification and a copied value from another board is a guess.
On a rail with six modules the compensation has to be consistent across them, because the modules share a bus and a loop. A single module tuned fast and five tuned slow produces a rail that rings at the frequency of the slowest one and is stable only at steady state. The vendor's own multiphase application circuits are the starting point for that, and the sequence of load steps on the finished board is the acceptance test.
Point eight percent on 1 V is a sense line problem before it is a silicon problem
Eight millivolts of dc error includes the drop in the sense lines and the ground return. A 50 A return through 0.2 milliohms is 10 mV, which is larger than the entire budget, so the differential sense amplifier has to be connected at the load and the return has to be a plane rather than a trace. On a 50 A rail the difference between a sense line taken at the module and one taken at the load is larger than the accuracy grade the part is bought for.
The same reasoning explains why the B grade exists: on a rail where the sense drop cannot be controlled tightly, the extra 0.7 percent of the A grade is spent on a tolerance that the interconnect already consumes. A build with a short, wide connection to the load benefits from the A grade; a build with a long one does not.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, one stop BOM sourcing covers what to check before a part is dropped into an existing board, and component lead time solutions is the route we take on a live shortage.
Two questions buyers ask
Can the two channels be used independently at 25 A each? Yes. The module is dual 25 A and each channel has its own output, feedback and compensation, so it can serve two rails. The 300 A sharing figure belongs to the single output configuration where the channels are paralleled across modules.
Does the E grade limit the ambient compared with the I grade? Both are listed at minus 40 degree C to 125 degree C, so the window is the same. What limits the ambient is the junction rise, which at 6.8 W of loss and 7 degree C per W is about 48 degree C, so a 77 degree C ambient is the practical ceiling at full load in still air.
What 300 A and a 3 percent transient ask of the output capacitor bank
Three hundred amps at 1 V with a 3 percent transient allowance is 30 mV of permitted deviation. If the loop takes 10 microseconds to respond, the capacitor bank has to supply 300 A for that window at 30 mV, which is 300 times 10 microseconds divided by 0.03 V, or 0.1 farad. That is 100,000 microfarads of ideal capacitance before any equivalent series resistance is counted.
The series resistance is what usually decides the number, because 300 A through 0.1 milliohm is 30 mV on its own, the whole allowance. A bank of ceramic parts in parallel can reach that, and a bank of electrolytics cannot without a large count. That is why a 300 A rail with a 3 percent transient figure is a capacitor project rather than a module selection: the module is the easy part, and the bank is what determines whether the transient claim holds on the finished board.