LTC1261IS8#PBF
Product Specifications
LTC1261IS8#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC1261IS8#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTC1261IS8: The 15 mA Headline Belongs to the Tripler, Not to Every Output Voltage
The LTC1261 is an inverting charge pump that runs from a single 3 V to 8 V supply and produces an adjustable output from minus 1.25 V to minus 8 V. The front page says up to 15 mA of output current, and a buyer reading only that line expects 15 mA at every setting. The regulation tables say something narrower: from a 5 V input in doubler mode the part holds regulation into 8 mA below 4 V of output and 7 mA above it, and in tripler mode from 3.3 V into a 4.5 V to 5 V output the guaranteed load is 3.5 mA. The 15 mA figure is the point at which turn on time is specified, not a working load for every configuration.
Doubler against tripler is a wiring decision
The 8 lead version is the doubler, with one flying capacitor between C1 plus and C1 minus. The 14 lead version adds the second flying capacitor pair and reaches the tripler mode that can make 5 V from a 3 V input. That extra stage is why the input range, the output range and the guaranteed load all change with the package. On a 3.3 V rail feeding a minus 5 V op amp supply, the part is in tripler mode and the load budget is 3.5 mA, which is one dual op amp and not a rail full of them.
Quiescent current and the shutdown pin
Supply current is 600 uA typical with no load, 1000 uA maximum over the commercial range and 1500 uA maximum over the industrial range, and 900 uA typical in tripler mode. Pulling the shutdown pin to the supply drops that to 5 uA typical and 20 uA maximum. A charge pump that runs continuously at 600 uA costs 5.3 mAh over a year, so on a battery product the shutdown pin is a control line and not an optional feature.
| Item | Published value | What it decides |
|---|---|---|
| Input range | 3 V to 8 V, 9 V absolute maximum | Works from 3.3 V or 5 V directly |
| Output range | minus 1.25 V to minus 8 V | Set by the resistor string or the fixed codes |
| Output ripple | 5 mV typical at 5 mA, 4 V out | Post regulator usually not needed |
| Oscillator | 550 kHz | Sets the ripple frequency and the capacitor size |
| Regulation window | 1 to 5 percent | Widens at the top of the output range |
The REG pin is a comparator, not a flag in software
The REG output pulls low when the output is within 5 percent of its set value, and it can sink 5 mA at 3.3 V or 8 to 15 mA at 5 V. That is enough to drive an LED or a logic input directly, and it is the intended way to sequence a downstream analog stage that must not come up before the negative rail is in regulation. On a board where the negative rail feeds an amplifier input, using REG as the enable removes a comparator and a divider from the board.
Fault behaviour and settling
Output short circuit current is 60 mA typical and 125 mA maximum, and the output can be shorted indefinitely, so the part survives a probe slip. Turn on time is 500 us at 15 mA, and the reference is 1.24 V with a 1.20 V to 1.28 V window, which is 3.2 percent and is the term to include when the negative rail sets an amplifier bias point rather than only a headroom number. Output voltage hysteresis is 40 ppm, small enough that a power cycle does not shift the set point.
Buying the industrial code
The IS8 code is the minus 40 to plus 85 C grade; the C codes are 0 to 70 C. They are the same silicon with a different test window, and the maximum supply current differs between them, so a hot board should not be filled with the C code on the assumption that the die is the same. The component lead time solutions page covers grade substitution under shortage, the pin to pin cross reference page covers the package, and lot checks follow the incoming inspection plan.