Contact Us

LTM4630EY-1A#PBF

Brand: Analog Devices
Analog Devices LTM4630EY-1A#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4630EY-1A#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4630EY-1A#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4630EY-1A#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM4630EY-1A#PBF: Dual 18 A With a Date Code That Changes the Ratings

The LTM4630EY-1A#PBF is a dual 18 A, or single 36 A, step-down module in a 16 mm by 16 mm ball grid array, and it carries one of the more unusual footnotes in power module documentation: the input range of 4.5 V to 18 V and the output range of 0.6 V to 8 V apply to parts made after date code 1720. Parts before that date code were rated 4.5 V to 15 V in and 0.6 V to 1.8 V out, and the change was made in a revision that moved the maximum input voltage from 15 V to 18 V. A reader who takes only the front page can therefore specify a voltage that a module from an older reel will not survive, and the date code on the reel is the only way to tell.

Two outputs, or one at twice the current

Each output is set by one external resistor and carries 18 A continuously, and the two can be paralleled for 36 A or combined with other modules for up to 144 A with eight in parallel. The two channels share the package and the thermal path, so the derating for both loaded is stricter than for one, and the current sharing between the two is set by the internal loop rather than by external ballast. A single 36 A rail from this package is a real option and needs the output path to be planned as a 36 A path, which at 1 V is 36 W and a copper question as much as a regulator question.

The -1A suffix and the ordering question

The ordering information for the family lists the LGA and BGA bodies with E and I temperature grades, and the -1A suffix on this order code is a variant that does not appear in that table, so its definition has to be confirmed against the vendor's current ordering information before it is treated as interchangeable with a plain LTM4630AEY. The practical rule for a buyer is that the base part number plus the temperature letter plus the body letter identifies the electrical part, and anything else appended to it is a variant that has to be checked rather than assumed. That is exactly the kind of difference that turns a drop-in replacement into a re-qualification.

ParameterValue on this order codeWhat it decides
Outputs2 at 18 A, or 1 at 36 A144 A with eight modules in parallel
Input range4.5 V to 18 V after date code 1720Older reels are rated to 15 V
Output range0.6 V to 8 V after date code 1720Older reels stop at 1.8 V
AccuracyPlus or minus 1.5 percent over temperatureTotal direct current output error
Light loadHigher efficiency than the LTM4630Burst mode and pulse skipping selectable
Remote senseDifferential amplifierRegulation at the load, not at the module
Temperature monitorInternal diodeHost can read the die temperature
Pin compatibilityLTM4620A dual 13 A, LTM4630 dual 18 ACurrent upgrade without a board change
PackageBGA, 16 mm by 16 mm by 5.01 mmThe taller of the two bodies

Why the date code matters to a buyer

A module with an 18 V input rating and one with a 15 V input rating are the same part number in a catalogue and different parts on a board. Distribution stock can be a mixture of both for a period after a rating change, and the only marker is the date code on the packaging. A production line that buys this module for a 16 V rail has to specify the date code, or accept that some units will be outside their rating from the first day. This is not a quality problem, it is a documentation problem, and it is solved by putting the requirement on the purchase order rather than in a product note.

Where the part belongs

Datacom and telecom boards with a 12 V backplane, processor and memory rails that need two independent voltages, and any board that has to grow from 18 A to 36 A without a board revision are the intended sockets. Where the input is above 18 V, or above 15 V on older stock, a different module is required. The ADI part second source page sets out what a substitution has to match, the pin to pin cross reference covers the family, and the one stop BOM sourcing page covers the modules and their output capacitors on one order.

Second side reflow and the moisture bar

The ordering notes carry two assembly constraints that are easy to lose between the drawing and the production line. The module is moisture sensitive at level 3, so its floor life after the dry pack is opened is finite and a partially used tray has to be baked before it goes back into reflow. It is also not recommended for second side reflow, which means the board has to be built with the module on the side that is reflowed first, or the module has to be attached in a later operation. Both constraints change the assembly sequence, and both are cheaper to plan around than to discover when the first production batch is already on the line.