LTC6101CIS5#TRPBF
Product Specifications
LTC6101CIS5#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC6101CIS5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC6101CIS5 in an industrial temperature slot
The LTC6101CIS5 is the loosest grade letter with the I temperature letter, plain 4 V to 60 V supply, 70 V absolute maximum, five lead SOT-23. It is the combination for a status or protection channel that runs in a hot cabinet: the temperature guarantee is the one that matters at 105 C ambient, and the grade letter is the one that can be given away when the sense drop is wide.
Why the temperature letter outranks the grade letter here
The family page publishes -40 to 125 C as the specified range and -55 to 125 C as the operating range, with each letter's guarantee in the ordering information. On a channel that sits at 105 C, a part that is only guaranteed to 70 C is outside its window whatever its offset figure says, and the offset is not the failure mode: the failure mode is a parameter that is simply not guaranteed. Buy the I letter first and the grade letter second, and only then argue about the offset limit.
A protection channel in numbers
| Item | Value | Why it matters |
|---|---|---|
| Shunt 5 mohm at 10 A | 50 mV, 0.5 W | the resistor is now the heat source |
| Offset on the family figure | 300 uV, 0.6 percent | the loose grade doubles or triples this |
| Common mode error at 48 V | 60 uV | 0.12 percent of the same drop |
| Response time | 1 us | one switching period at 500 kHz |
| Output limit | 1 mA | gain of 20 into 1 kohm is at it |
A trip threshold at 12 A on a 10 A channel has 2 A of band, which is 10 mV of sense drop, and the offset term even at three times the family figure is 0.9 mV. The threshold band is ten times the error, so the loose grade does not move the trip point in any way the protection scheme can see. That is the calculation that justifies this code, and it should be done rather than assumed.
The 60 V ceiling in a hot cabinet
A 48 V rail at plus 10 percent is 52.8 V and the absolute maximum is 70 V, so 17.2 V of transient headroom is all this part offers. In a cabinet where the bus is fed by a switching supply with a defined clamp, that is enough. On a bus with a motor or a long cable, the HV member of the family with its 105 V absolute maximum is the right part and this one is not.
Where this code fits
Protection and status channels on 24 V and 48 V equipment inside sealed enclosures, fan and pump monitoring at high ambient, and any channel where the reading supports a decision rather than a specification. Keep the gain pair in the low kiloohms so the 170 nA of bias stays under 0.5 percent of the sense drop, and keep the output under 1 mA at fault current.
What a 105 C ambient changes
At 105 C the parts of the chain that drift are the shunt, the reference and the amplifier offset, and they do not drift equally. A 5 mohm shunt with a 50 ppm per degree coefficient moves 0.4 percent over an 80 degree rise from room, which on a 50 mV operating point is 200 uV. The reference behind the comparator moves by its own figure, typically far more. The amplifier's contribution is bounded by the offset limit that the ordering information attaches to the letter in the part number, which is why the temperature letter is worth more than the grade letter on a hot board: the guarantee either covers 105 C or it does not, and no amount of grade tightening fixes a window that stops at 70 C. Check the enclosure ambient at the part rather than at the inlet, because a 40 C inlet with a 30 degree rise inside the box puts the sense amplifier exactly at the boundary where the commercial letter runs out.
Sourcing notes and next step
Order lines for this family drift between grades because the outside letters look alike, so quote the full code including the temperature letter and check the date code on arrival. Where the exact code is short, the A grade at the same temperature letter is a drop in that improves the offset, and it is a safer substitution than a tighter grade at a narrower temperature window. Our ADI second source page lists the codes we can quote, the BOM shortage route covers mixed bills, and the analog and mixed signal category holds the rest of the family.
Request Quote — In Stock, 100% New & Original, Full Warranty