LTC6101AIS5#TRPBF
Product Specifications
LTC6101AIS5#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC6101AIS5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC6101AIS5 in a 60 V socket at 105 C
The LTC6101AIS5 pairs the A grade letter with the I temperature letter on the plain 4 V to 60 V member of the family, in the five lead SOT-23 with a 70 V absolute maximum. It is the code for a channel that lives on a 48 V nominal rail inside a hot enclosure: the operating ceiling clears a 52.8 V bus at plus 10 percent by 7.2 V, and the I letter is the window that holds to 125 C rather than the commercial one.
The margin a 48 V bus leaves on a 60 V part
48 V at plus 10 percent is 52.8 V and at plus 20 percent is 57.6 V, both inside the 60 V operating ceiling. The absolute maximum is 70 V, so a transient of 12 V above the highest legal steady state is the end of the part. That is thin for a bus with a motor or a long cable on it, and the honest reading of the family table is that the plain part is a 24 V and 36 V device that can survive a 48 V rail, while the HV part is the 48 V device. Choose on the energy of the transient, not on the nominal voltage.
Sound engineering questions the page can answer with numbers
| Question | Answer from the published figures |
|---|---|
| How much does the shunt cost me in heat | 10 mohm at 5 A is 50 mV and 0.25 W |
| Can I use a 1 mohm shunt | 5 mV at 5 A, and 300 uV of offset is 6 percent of it |
| How fast can the output move | 1 us for a 0 V to 2.5 V step |
| How much current can the output source | 1 mA maximum |
| What does the monitor cost in standby | 250 uA at 12 V, 2.19 Ah over a year |
The first two rows are the decision. A 1 mohm shunt is tempting because it burns 25 mW at 5 A, but the offset share rises from 0.6 percent to 6 percent and the common mode error at 48 V, which is 60 uV from the 118 dB minimum rejection, rises from 0.12 percent to 1.2 percent of the same 5 mV. A 10 mohm shunt costs 0.25 W and keeps both terms below 1 percent on a 50 mV sense drop. On a 5 A channel that 0.25 W is 1 percent of the 24 W being delivered, which is usually the right trade.
Bias current and the gain pair
The input bias current limit is 170 nA. Into 1 kohm that is 170 uV, 0.34 percent of a 50 mV sense drop; into 10 kohm it is 1.7 mV, which is 3.4 percent and larger than everything else in the chain. The family is a current output device, so the two gain resistors set both the gain and the impedance the input sees, and keeping them in the low kiloohms is what keeps the bias term out of the answer. The same resistors then have to keep the output under 1 mA at rated current and at fault current.
Where this code fits
48 V industrial rails inside a sealed enclosure, 36 V battery systems that see a 45 V charger, motor phase current on a 48 V drive, and telecom equipment where the ambient at the part is 85 C rather than 25 C. The 1 us response supports a comparator trip inside a switching period.
Sourcing notes and next step
The plain and HV parts share a body and a pin map, so the only defence against fitting the wrong one is the order line and the reel label. Where the I letter is short and the schedule matters, the commercial letter is the same die with a narrower guarantee, and that is a decision for the engineer who owns the thermal budget rather than for the buyer. Our ADI second source page lists the codes we can quote, the lead time page covers the schedule case, and the analog and mixed signal category holds the rest of the family.
Request Quote — In Stock, 100% New & Original, Full Warranty