LTC6101ACS5#TRPBF
Product Specifications
LTC6101ACS5#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC6101ACS5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC6101ACS5 on a 24 V industrial rail
The LTC6101ACS5 is the plain, not the HV, member of the family: 4 V to 60 V of supply with a 70 V absolute maximum, the A grade letter and the C temperature letter in the five lead SOT-23. The 10 V of headroom between the operating ceiling and the absolute maximum is 14.29 percent, which is the most margin any code in this family has, and it is the reason a 24 V rail with a switching supply in front of it is a comfortable place for this part.
What a 24 V rail leaves on the table
A 24 V rail at plus 10 percent is 26.4 V, which is 33.6 V below the ceiling. A 36 V battery string at full charge is 41 V, still inside. A 48 V bus at plus 10 percent is 52.8 V, also inside the 60 V operating ceiling but only 17 V below the 70 V absolute maximum, and that is where the plain part stops being the safe choice: a load dump or an inductive kick of 20 V puts the pin at the absolute maximum, while the HV member of the family has 105 V for the same event. The rule that follows is simple. Sense a 24 V or 36 V rail with the plain part, sense a 48 V rail with the HV part.
The accuracy stack on a 50 mV sense
| Term | Figure | Share of a 50 mV sense drop |
|---|---|---|
| Offset voltage | 300 uV maximum | 0.60 percent |
| Common mode error at 24 V | 30 uV from 118 dB minimum | 0.06 percent |
| Bias current through 1 kohm | 170 uV from 170 nA maximum | 0.34 percent |
| Shunt tolerance (1 percent part) | user chosen | 1.00 percent |
The shunt dominates, which is the useful finding: on a 50 mV sense drop the amplifier terms add up to about 1 percent and the resistor alone is 1 percent, so paying for a tighter grade does not buy a tighter reading unless the shunt is also a 0.1 percent part. Where the sense drop falls to 10 mV, the offset alone is 3 percent and the ordering changes, and that is the point at which the grade letter earns its price.
Supply current and the output limit
At 12 V the part draws 250 uA, which is 2.19 Ah over a year, so a permanently enabled monitor on a 24 V battery product has to be counted in the standby budget. The output is a current with a 1 mA maximum: a 50 mV sense with a gain of 20 gives 1 V, and 1 V across a 1 kohm resistor is exactly 1 mA, so the gain resistor is what keeps a fault from saturating the stage.
Where this code fits
24 V industrial supplies, 12 V and 24 V battery monitoring, motor drives below 48 V, and any high side channel where the bus cannot produce a transient above 70 V. The 1 us response suits a hardware overcurrent comparator; a sampled loop does not need it.
What the 1 mA output limit does on a fault
A 24 V rail that faults to twice its rated current does not announce itself politely. With a 10 mohm shunt and 10 A of fault current the sense drop is 100 mV, and a gain of 20 would ask the output for 2 V across a 1 kohm resistor, which is 2 mA against a 1 mA limit. The stage saturates at half the expected reading and the controller sees a current that stops rising exactly when it should be rising fastest. Setting the gain resistor at 2 kohm keeps 10 A inside the limit and puts 20 A at the ceiling, which is where a fault channel wants its headroom. The same arithmetic applies at the bottom of the range: a 2 kohm resistor turns a 10 mV sense into 0.2 V, and 0.2 V is still well above the offset and bias terms that the earlier sections priced out.
Sourcing notes and next step
This code and the HV code look identical on a board and differ only in the letters after LTC6101, so a cross reference has to match the supply range first and the grade second. A 60 V part in a 48 V socket is the mistake this family invites. Our ADI second source page lists the codes we can quote, the BOM shortage route covers mixed bills, and the analog and mixed signal category holds the rest of the family.
Request Quote — In Stock, 100% New & Original, Full Warranty