The LTC4015IUHF#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC4015IUHF on an industrial temperature charger
The LTC4015IUHF is the I temperature letter of the same multichemistry buck charger controller: 4.5 V to 35 V of input, a 35 V battery ceiling, pin selectable Li-Ion, LiFePO4 or lead acid algorithms, and a 14-bit ADC with a coulomb counter behind an I2C port. The letter is the difference, and on a charger that lives in a cabinet the letter is the whole reason to pay for the I grade.
Why a charger needs the wider window
A charger dissipates more than any other block on the board and it does so next to the battery, which is the component with the tightest temperature limit. The controller sits in that pocket. Its own current is small, but the die temperature it reports is a real measurement of the local environment, and the guarantee of the part has to cover the ambient that the enclosure produces after a full charge cycle at 40 C inlet. The E letter covers the commercial window; the I letter covers the industrial one. Read the ordering information for the exact limits, then measure the board rather than assume it.
Input and battery heads at the ceilings
| Rail | Worst case | Against the 35 V ceiling |
|---|---|---|
| 24 V bus at plus 10 percent | 26.4 V | 8.6 V of headroom |
| Eight Li-Ion cells at 4.2 V | 33.6 V | 1.4 V of headroom |
| Nine Li-Ion cells at 4.2 V | 37.8 V | outside the part |
| 24 V lead acid at absorption | 28.8 V | 6.2 V of headroom |
The eight cell row is the tight one and it is a real operating point: 33.6 V at full charge leaves 1.4 V against the ceiling, so a pack that is charged above 4.2 V per cell, or a sense lead that adds drop, puts the part at its limit. Either stay at seven cells or move to a controller with a higher battery ceiling.
Telemetry resolution against the job
Fourteen bits over 35 V is 2.136 mV per code, which resolves a 4.2 V cell voltage to half a millivolt per code only if the reading is scaled to the cell rather than to the pack. Over a 2.5 V span the same converter gives 152.6 uV per code. The coulomb counter is the more useful instrument for state of charge: it integrates current, so its accuracy depends on the sense resistor and its offset rather than on the ADC, and a 1 percent resistor is a 1 percent fuel gauge no matter how many bits the converter has.
Power stage at 8 A
Twenty-four volts in to a 25.2 V pack at 8 A is 201.6 W out and about 210 W in at 96 percent, so 8.4 W of loss sits in the FETs, the inductor and the sense element. That is a copper and thermal question, and the controller's contribution is the gate drive and the loop. Keep the charge current sense resistor out of the thermal shadow of the FETs, because its value moves with temperature and the current limit follows it.
Where this code fits
Industrial battery backup, medical carts that are charged in a warm room, telecom 24 V plants with a battery string, and any charger whose enclosure reaches 60 C. The instant-on PowerPath operation means the system rail is available with a flat battery, which is often the requirement that decides the architecture.
Sourcing notes and next step
Ask for the full order code with the temperature letter and check the chemistry strap against the pack on arrival, because the same part number serves three algorithms. Our ADI second source page lists what we can quote against a code, the BOM shortage route covers mixed bills, and the analog and mixed signal category holds the rest of the charger family.