Contact Us

LTC3787IUFD#TRPBF

Brand: Analog Devices
Analog Devices LTC3787IUFD#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC3787IUFD#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC3787IUFD#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC3787IUFD#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC3787IUFD in an industrial boost stage

The LTC3787IUFD is the I temperature letter of the two-phase synchronous boost controller: 4.5 V to 38 V of input with a 40 V absolute maximum, operation to 2.5 V after start-up, output to 60 V, a 1.200 V reference at plus or minus 1 percent, and two out of phase N-channel stages in a 28-pin 4 by 5 mm QFN. The letter is the guaranteed window, and on a boost stage in a cabinet the window is what the thermal analysis rests on.

The input ceiling is the first filter

A 24 V bus at plus 10 percent is 26.4 V and sits 11.6 V below the ceiling. A 36 V bus at plus 10 percent is 39.6 V and is outside it. That single row rules the part in or out before any other consideration, and it is the row most often skipped when a boost controller is chosen from a family table. The 40 V absolute maximum gives 4 percent of margin over the operating ceiling, so a transient clamp on the input is part of the circuit.

Loss, duty and the two phases

CaseDutyOutputLoss at 95 percent
12 V to 24 V at 10 A50.0 percent240 W12.63 W
12 V to 48 V at 5 A75.0 percent240 W12.63 W
5 V to 12 V at 5 A58.3 percent60 W3.16 W

Two phases halve the ripple current that each input capacitor sees and allow two smaller inductors instead of one large one, which is usually a height and cost decision rather than an electrical one. The 100 percent duty cycle capability for the synchronous MOSFET matters at start-up and in a cold crank event, where the input is close to the output and the boost has to pass through rather than regulate.

Current sensing choice

Sensing across a resistor gives a defined, temperature stable current limit and burns power in the resistor. Sensing through the inductor resistance removes the dissipating element, but the copper resistance rises with temperature, so the current limit falls as the board heats. On an industrial boost stage running at 240 W that difference is worth deciding deliberately: a resistor gives a predictable limit and a thermal budget line, and the inductor method gives efficiency and a limit that drifts.

Standby and control

Quiescent current of 135 uA is 1.18 Ah over a year, and the sub 8 uA shutdown state is 0.07 Ah, so a stage that is off most of the time does not need to be isolated to protect the battery. The phase lockable oscillator runs 75 kHz to 850 kHz and the fixed frequency range is 50 kHz to 900 kHz, which lets the stage be moved away from an intermediate frequency that the rest of the system uses, or synchronised to it when beat frequencies would otherwise appear in the output ripple.

Where this code fits

Industrial 24 V to 48 V conversion, battery backup boost stages, and power factor corrected front ends where the output has to hold up during a line dip. The I letter suits a cabinet that reaches 70 C internal, and the AEC-Q100 members of the family are the automotive route.

Ripple, inductor value and the two phases

Ripple current in a boost is set by the input voltage, the duty cycle, the inductor and the frequency: input times duty, divided by inductance times frequency. At 12 V in, 24 V out and 10 A, the duty is 50 percent, and with a 4.7 uH inductor at 300 kHz each phase carries about 4.26 A of ripple. Two phases at 180 degrees add their ripple at the input in antiphase, so the input capacitor sees a smaller net ripple than the same total current in one phase, which is why the two phase arrangement allows smaller capacitors and two smaller inductors rather than one large one. Raise the frequency and the ripple falls in proportion, at the cost of more switching loss in the same FETs. Lower the inductance and the ripple rises, which moves the peak current that the FET and the sense element have to carry. Those three numbers, inductance, frequency and peak current, are one decision, and the controller sets none of them by itself.

Sourcing notes and next step

Confirm the input ceiling and the output divider first, then the temperature letter. Our ADI second source page lists what we can quote, the power management cross reference covers the neighbouring controllers, and the analog and mixed signal category holds the rest of the family.

LTC3787IUFD#TRPBF: 39.6 V on the bus leaves one percent to a 40 V absolute maximum, and the two phases split 12.63 W

The operating ceiling and the absolute maximum are different numbers: the regulator works to 38.4 V and survives 40 V. A 36 V bus at plus ten percent is 39.6 V, which is inside the absolute maximum by 0.4 V, one percent, and above the operating ceiling entirely. That margin is not a margin allowance, it is the absence of one, so an input clamp belongs in front of the part on any 36 V bus. A 24 V bus at plus ten percent is 26.4 V and sits 11.6 V below the operating ceiling, which is the case the part is comfortable in.

Splitting the loss between the phases

Two hundred and forty watts at 95 percent efficiency is 12.63 W of loss, or 6.3 W per phase. The input current for that load from 12 V is 21.05 A in total, 10.5 A per phase, and each phase's synchronous MOSFET carries it at a 75 percent duty when the output is 48 V. The 100 percent duty capability matters at start-up and during a cold crank, when the input is close to the output and the boost stage has to pass through instead of regulating, and a controller without it would drop the output at the very moment the load needs it most.

Why two phases instead of one bigger one

Two phases at 180 degrees put their ripple in antiphase at the input, so the input capacitor sees a smaller net ripple than the same total current in one phase, and the two inductors are each half the current of a single one. The practical effect is smaller magnetics and fewer capacitors, at the cost of one more inductor and one more pair of FETs. Below about 100 W the second phase stops paying for itself; at 240 W it is the reason the stage fits on the board at all.

Standby, and the 135 uA that is not the number to budget on

Quiescent current of 135 uA is 1.18 Ah over a year and the sub 8 uA shutdown state is 0.07 Ah, a factor of 17. A stage that is off most of the time is therefore cheap to keep, but only if the shutdown pin is actually used: a controller left enabled because the shutdown signal was not routed costs 1.18 Ah a year rather than 0.07. That is the whole difference between an always-on boost stage and one that sleeps, and it is a board routing decision rather than a specification one.

Bus voltageAgainst the 38.4 V operating ceilingAgainst the 40 V absolute maximumAction
24 V at plus 10 percent11.6 V below13.6 V belowno clamp needed
28 V at plus 10 percent7.6 V below9.6 V belowno clamp needed
36 V at nominal2.4 V below4.0 V belowclamp recommended
36 V at plus 10 percent1.2 V above0.4 V belowclamp required