LTC2411CMS#TRPBF
Product Specifications
LTC2411CMS#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC2411CMS#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC2411CMS#TRPBF: A 24-Bit Converter That Rejects the Mains Line Without a Filter
The LTC2411CMS#TRPBF is a 24-bit no latency delta sigma converter in a 10-lead MSOP. It runs from 2.7 V to 5.5 V, draws 200 uA in conversion mode and 4 uA in autosleep, has a differential input and a differential reference, accepts a reference from 0.1 V to the supply rail, and allows the input common mode and the reference common mode to be set independently anywhere between ground and the supply. Integral nonlinearity is 2 ppm, full-scale error is 4 ppm, offset is 1 ppm, noise is 0.29 ppm rms, and the digital filter settles in a single cycle so every conversion is accurate even after an input step. One pin selects better than 110 dB of rejection at 50 Hz or 60 Hz within 2 percent; the -1 variant gives better than 87 dB across 49 Hz to 61.2 Hz instead. The internal oscillator removes the need for any external timing component.
The single cycle settling is what makes this converter useful in a multiplexed instrument. A converter with a long settling tail needs a delay after every channel change, and that delay is dead time. Here the reading after the switch is already valid, so the scan rate is set by the conversion rate and not by a settling allowance.
Two hundred microamps in conversion and four in autosleep
At 5 V the conversion current is 1 mW, which is 1.75 Ah over a year if the converter never sleeps. The autosleep state at 4 uA is 35 mAh over a year, fifty times less, and the part wakes on the next conversion command rather than on a separate enable. For a battery instrument that reads a sensor once a second, the difference between the two states is the difference between a fortnight and a year of cell life, and nothing else in the signal chain has to change to get it.
The 0.29 ppm rms noise is 1.45 uV at a 5 V full scale and 4.87 codes at 24 bits. With a crest factor of 6.6 the peak to peak noise is 9.57 uV, so the noise free resolution is 19.0 bits. The 2 ppm linearity is 10 uV and the 4 ppm full-scale error is 20 uV, so the error terms sit above the noise and the converter is limited by its own accuracy rather than by its noise floor.
A differential reference is what makes a ratiometric bridge exact
Because the reference input is differential and independent of the signal common mode, the bridge excitation can be the reference. The converter then measures the ratio of the bridge output to its own excitation, and any drift in the excitation cancels in the arithmetic rather than appearing in the reading. A single-ended reference forces the excitation to be a separate, stable source, which is the part of a bridge circuit that usually costs the most.
The full-scale differential input is plus and minus half the reference, so a 2.5 V reference gives a 2.5 V peak to peak span around the input common mode. The common mode rejection of the input is better than 140 dB at DC, which is what allows the bridge to sit at half the excitation while the reference sits at a different potential. None of that needs an external amplifier, and the 110 dB line rejection means a 50 Hz or 60 Hz pickup on the leads is attenuated before it reaches the digital filter.
| Word length | 24 bit, no latency, single cycle settling |
| Noise | 0.29 ppm rms, 1.45 uV at 5 V, 19.0 bits noise free |
| Accuracy | 2 ppm INL, 4 ppm full-scale error, 1 ppm offset |
| Input | Differential, common mode ground to supply, 140 dB DC rejection |
| Reference | Differential, 0.1 V to the supply rail, independent common mode |
| Full scale | Plus and minus half the reference, 2.5 V peak to peak on a 2.5 V reference |
| Line rejection | 110 dB minimum at 50 Hz or 60 Hz within 2 percent, 87 dB across 49 to 61.2 Hz on the -1 |
| Supply current | 200 uA converting, 1 mW at 5 V, 4 uA in autosleep, 35 mAh over a year |
| Supply and clock | 2.7 V to 5.5 V, internal oscillator, no external timing parts |
| Package | 10-lead MSOP |
Two questions buyers ask
Which variant, the plain part or the -1?
The plain part rejects 50 Hz or 60 Hz within 2 percent of the selected frequency, at better than 110 dB. The -1 rejects everything from 49 Hz to 61.2 Hz at better than 87 dB, which is 23 dB less rejection but works on a grid whose frequency wanders or on equipment that ships to both 50 Hz and 60 Hz markets. A product that is installed in one country and never moves takes the plain part and the extra rejection.
Does it need an anti-alias filter in front?
The digital filter rejects the line frequency but not the frequencies above its pass band, so a sensor lead that can pick up switching noise still needs a small RC. The input is differential and the source impedance is tolerated, so the filter is a resistor pair and a capacitor rather than a buffer stage.
Ordering and supply
The CMS suffix is the 10-lead MSOP on the commercial temperature grade, and the TRPBF suffix is tape and reel, lead free. The variant letter matters here more than the package: plain and -1 differ in rejection bandwidth and are not interchangeable in an instrument that was qualified against one of them.
We source this family for production and for repair lots. Start at the analog mixed signal ICs family page, compare a candidate against the ADC and DAC cross reference, and where an instrument is waiting on a converter, component lead time solutions sets out how a qualified alternative is checked against the rejection and the reference structure rather than against the pin count alone.
Request Quote — In Stock, 100% New & Original, Full Warranty