LTC2054HVCS5#TRPBF
Product Specifications
LTC2054HVCS5#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC2054HVCS5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC2054HVCS5 zero drift amplifier on a plus and minus 5 V rail
The LTC2054HVCS5 is the high voltage member of the single zero drift amplifier family in the 5-lead SOT-23 body. The plain LTC2054 runs from 2.7 V to 6 V, which is a single supply part. The HV suffix lifts the total supply to 11 V, which is what allows the same die to sit across a plus and minus 5 V analog rail. The C letter is the commercial temperature grade of this order code.
What the HV suffix actually unlocks
Eleven volts total is plus and minus 5.5 V, or a single 10 V rail. That matters because a plus and minus 5 V signal chain is still the default in industrial instrumentation, and a 6 V part cannot sit on it. The common mode range runs from the negative supply to 0.5 V below the positive supply, so on a plus and minus 5 V rail the usable input window is minus 5 V to plus 4.5 V. A sensor that swings to the positive rail is outside the window, and no amount of rail to rail output fixes that, because the output is rail to rail and the input is not.
Three microvolts in converter terms
| Converter | Full scale | One LSB | 3 uV offset in LSB | 1.6 uV peak to peak noise in LSB |
|---|---|---|---|---|
| 16 bit | 5.0 V | 76.3 uV | 0.039 | 0.021 |
| 16 bit | 2.5 V | 38.1 uV | 0.079 | 0.042 |
| 18 bit | 5.0 V | 19.1 uV | 0.157 | 0.084 |
| 24 bit | 5.0 V | 0.298 uV | 10.1 | 5.37 |
Up to 18 bits the amplifier is not the limit, which is the whole argument for a zero drift part in front of a delta sigma converter. At 24 bits the 3 uV offset is ten codes and the 0.01 Hz to 10 Hz noise is five codes, so the converter resolution is being spent on the amplifier and the reference. That is not a reason to reject the part, it is a reason to stop quoting 24 bit resolution on a 5 V span without a chopping front end and a better reference.
Drift is the number that survives temperature
The maximum offset drift is 30 nV per degree C. Over the 125 degree industrial span that is 3.75 uV, which is larger than the 3 uV offset the part is bought for, so a channel trimmed at 25 C is not trimmed at 125 C: it is trimmed to within the drift term. This is the honest way to read zero drift: the offset is small and stable, not zero, and the residual is the drift multiplied by the excursion. For a 40 degree excursion, which is a realistic cabinet, the drift term is 1.2 uV and the offset dominates.
Bias current against source impedance
One picoamp of typical bias current is 1 uV into 1 Mohm, 10 uV into 10 Mohm and 100 uV into 100 Mohm. So on a low impedance bridge the bias is nothing, and on a 100 Mohm pH electrode the bias is thirty times the offset. A zero drift amplifier is not automatically the right front end for a very high impedance sensor: the input current has to be compared with the offset at the actual source impedance, not read from the headline alone.
Power and bandwidth budget
The supply current is 150 uA maximum per amplifier, which is 450 uW at 3 V and 750 uW at 5 V, or 1.31 Ah over a year if the channel is always on. The gain bandwidth is 500 kHz, so a gain of 10 leaves about 50 kHz of closed loop bandwidth and a gain of 100 leaves about 5 kHz. A 1 V peak to peak signal at 5 kHz needs 0.016 V per microsecond of slew, which is a modest ask, but the same signal at 500 kHz needs 1.57 V per microsecond, which a 150 uA chopper does not have. Check the slew requirement against the frequency before trusting the gain bandwidth product.
Chopping, source impedance and the filter that fixes both
A zero drift amplifier corrects its offset continuously, and the correction involves switching at the input. The switching presents a small charge to whatever is connected, so a high source impedance does not only turn bias current into voltage, it also turns the switching charge into a voltage step that the amplifier then amplifies. The usual treatment is a resistor and a capacitor at the input: the resistor isolates the source from the switching node and the capacitor holds the charge. The resistor has to be small enough that its own noise and the bias current do not add more than the offset, and 1 kohm is a reasonable starting point for a bridge or a thermocouple, with 10 kohm or more only where the signal is slow.
The same filter sets the noise bandwidth. Above 10 Hz the noise density, not the peak to peak figure, is the term to use, and a single pole at 10 Hz cuts the wideband contribution while leaving a 100 Hz signal intact. That is why the 0.01 Hz to 10 Hz number is the right one for a weighing scale and the wrong one for a vibration channel.
Questions that come up on this part
Is the input rail to rail? No. The output is rail to rail, the input common mode stops 0.5 V below the positive rail and reaches the negative rail. On a plus and minus 5 V supply the usable window is minus 5 V to plus 4.5 V.
Can it run from a single 12 V rail? No. The HV suffix is 11 V total, so a 12 V rail is outside the part even though it is only one volt more. A 10 V rail is the practical ceiling.
Does it need an offset trim? No. The 3 uV maximum offset is the reason to use a chopper instead of a trimmed general purpose amplifier, and a trim pot would add drift rather than remove it.
Is it unity gain stable? Yes, and the 500 kHz gain bandwidth is a small signal figure at unity gain, so a follower is limited by slew rate well before that frequency.
Sourcing notes and next step
Confirm three things on this code: the HV suffix, the C or I letter, and the package, because the same function appears in SOT-23, MS8 and DFN and they are not interchangeable on a board. Our amplifier cross reference page lists what we can quote against a code, the drop in replacement page covers the verification steps, and the analog and mixed signal category holds the rest of the zero drift family.