LT8613IUDE#TRPBF

Brand: Analog Devices
Analog Devices LT8613IUDE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT8613IUDE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT8613IUDE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT8613IUDE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LT8613IUDE#TRPBF: a 6 A rail for a 24 V industrial bus that starts cold

The LT8613IUDE#TRPBF is the I grade of the 6 A, 42 V step-down regulator with the current sense amplifier, in the 28-lead 3 mm by 6 mm QFN, guaranteed over the full minus 40 C to 125 C junction range. It is the part for a 24 V industrial bus that feeds a 5 V rail at several amps, where the board has to start in an unheated cabinet and the load may be a bank of capacitors or a battery rather than a resistor.

The figures a 24 V industrial rail depends on

Grade on this codeI, guaranteed minus 40 C to 125 C junction
Input range3.4 V to 42 V
Output current6 A
Current senserail-to-rail amplifier with monitor and control pins
Quiescent current3 uA in burst mode
Minimum on time40 ns
Frequency200 kHz to 2.2 MHz, synchronisable
Dropout250 mV at 3 A
Power goodplus or minus 9 percent of the set output

A 24 V bus at plus or minus 20 percent

A 24 V industrial bus is often specified at plus or minus 20 percent, which is 28.8 V at the top and 19.2 V at the bottom, and the 42 V rating covers both with room for a transient. The bottom of the band is the case that decides the 5 V rail: at 19.2 V in and 5 V out the duty cycle is 26 percent, and at 1 MHz the on time is 260 ns, far above the 40 ns floor. The top of the band is where the floor matters: 28.8 V to 5 V is 17.4 percent and 174 ns at 1 MHz, so the frequency can go much higher than the application needs.

The input current at 6 A out and 95 percent efficiency is 2.63 A from 12 V and 1.32 A from 24 V, so a 24 V bus halves the input current and the conduction loss in the connector and the input capacitor. The 3.4 V minimum input is irrelevant on this bus, and the 250 mV of dropout at 3 A is likewise not a concern until the bus collapses.

Starting into a capacitor bank at minus 40 C

The TR/SS pin takes a capacitor that sets the output ramp, and the ramp is what limits the inrush when a large output capacitance is charged. The current loop can be used for the same job: set the current limit below the inrush the bus can supply and the output rises at a rate set by that current rather than by the RC of the load. That is the more predictable method because the ramp rate is independent of the load capacitance, and it is the reason a current mode regulator is preferred for a board that may be hot plugged.

At minus 40 C the input capacitors of a 24 V bus lose capacitance if they are ceramics with a high dielectric constant, and the ESR of any aluminium part rises sharply. The result is an input loop that was quiet at 25 C and rings at cold, and the 40 ns on time does not help there. A 10 uF ceramic plus a bulk part is the usual answer, and the ceramic should be a stable dielectric rather than the smallest available case size.

Two questions buyers ask

Is the I grade a different part from the E grade? It is the same converter with a guarantee over the full temperature range rather than a 0 C to 125 C guarantee extended by characterisation. Electrically, the pinout, the frequency range and the current rating are identical, so a board qualified with the E part accepts the I part. A product that must show a minus 40 C start in its qualification report needs the I code on the bill of materials.

Does the current loop work with the output capacitor bank? Yes, and it is the better way to charge it. The loop regulates the current into the bank until the voltage reaches the set point, then hands over to the voltage loop. The one thing to check is the stability of the current loop with a very low ESR load, which is a matter of the compensation at the control pin rather than the regulator itself.

Sourcing notes and next step

Send the exact code with the I letter and the packaging suffix, the bus tolerance, and the load profile including any capacitor bank. Our second source page shows how an alternative is checked against the input range and the current loop, the BOM shortage page covers the grade substitution rules, and the analog and mixed signal category lists the rest of the family.

Request Quote — In Stock, 100% New & Original, Full Warranty