LT8610HMSE#TRPBF
Product Specifications
LT8610HMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8610HMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT8610HMSE#TRPBF: the 150 C grade without the automotive paper
LT8610HMSE#TRPBF is the H grade of the LT8610 in the 16-lead MSOP, on tape and reel, without the W prefix. It is the same 150 C junction part with the same 2.5 A rating, sold for industrial and instrumentation work where the ambient is high but the product is not a vehicle module.
Published values
| Parameter | Value |
|---|---|
| Junction grade | H, guaranteed over -40 C to 150 C |
| Input voltage | 3.4 V to 42 V |
| Continuous output | 2.5 A |
| Feedback reference | 0.970 V, 18 mV window |
| Minimum on time | 50 ns |
| Switching frequency | 200 kHz to 2.2 MHz |
| Dropout | 200 mV at 1 A |
| Quiescent current | 2.5 uA |
| Power good | plus or minus 9 percent, 297 mV at 3.3 V |
| Thermal resistance | 40 C/W |
| Efficiency | 96 percent at 1 A, 5 V out from 12 V |
| Package | 16-lead MSOP |
| Release | industrial, no W suffix |
A 150 C junction in a metal enclosure
An instrument in a sealed enclosure with no fan often sees 70 C to 85 C internal ambient. At 2.5 A into 5 V the part dissipates about 0.52 W, which is 21 C of rise on 40 C/W, so the junction sits at 106 C in an 85 C ambient and the 125 C grade would be at 84 percent of its limit before any other heat source is counted.
The H grade moves that limit to 150 C and turns a marginal rail into one with margin. The cost is test time, paid once per reel, against a thermal rework of the enclosure that would be paid once per product.
What the H grade does not fix
It does not raise the current rating, lower the dropout or change the reference. A rail that is limited by the 3.4 V minimum input or by the 50 ns floor is limited in exactly the same way at 150 C as at 125 C.
It also does not license running the junction at 150 C for life. The data sheet notes that continuous operation above the specified maximum reduces lifetime, and that the junction exceeds 150 C when the overtemperature protection is active, which is a protection event and not an operating point.
The 2.5 uA standby figure over a year
2.5 uA is 21.9 mAh over a year, and the 1 uA shutdown state is 8.76 mAh. In a battery product those numbers decide whether a standby rail can stay live across a shelf life, and they are small enough that the supervisor and the divider usually draw more than the converter.
A 100 kohm divider across a 12 V rail draws 120 uA, which is 48 times the converter's own standby current. That is the number to look at first when a standby budget is missed, not the buck.
Where a customer needs a second position on this part, component lead time solutions is the starting point, the power management cross reference sets out the checks a substitution has to pass, and OEM procurement is the short lead time route we quote against.
Two questions buyers ask
Is the H grade a different die from the I grade? It is the same silicon tested and guaranteed over a wider junction range. The electrical limits are the same numbers, promised to 150 C instead of 125 C.
Why choose this over the W version? Lead time and cost. The industrial release does not go through the automotive screening queue, so it is usually easier to find for an enclosure that is hot but not mobile.