LT8306RS6#TRMPBF
Product Specifications
LT8306RS6#TRMPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8306RS6#TRMPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8306RS6#TRMPBF: An Isolated Flyback With No Optocoupler and No Third Winding
The LT8306RS6#TRMPBF is a micropower isolated flyback controller from Analog Devices in a 6-lead TSOT-23. It regulates by sampling the isolated output voltage directly from the primary side flyback waveform, so the transformer needs no third winding and the feedback path needs no optocoupler. Input range is 4.5 V to 60 V, the output is set by a single external resistor, and the part drives a low side N-channel MOSFET with an 8 V gate drive. Operation is quasi-resonant boundary mode at heavy load and low ripple burst mode at light load, with a minimum load below 0.5 percent of full output. Quiescent current is 120 microamps in sleep mode and 390 microamps active, internal compensation and soft start are included, and the part is AEC-Q100 qualified with output short circuit protection.
Boundary mode is what makes the primary side sensing accurate enough
In boundary mode the secondary current reaches zero before the next switching cycle begins, so the flyback pulse on the primary is a clean copy of the output voltage plus the diode drop, scaled by the turns ratio. The controller samples that pulse at the moment the secondary current is at zero, which removes the effect of the leakage inductance and the diode forward drop that would otherwise corrupt a continuous mode measurement. The consequence for the magnetic part is that the transformer has to be specified for boundary mode operation with the right primary inductance, and a transformer from a continuous mode supply is not interchangeable. The single resistor sets the output because the sampled voltage is compared against an internal reference, and its tolerance and the transformer turns ratio are the two terms in the output accuracy.
At 48 V in and 12 V out the FET sees the sum, not the input
A flyback MOSFET blocks the input voltage plus the reflected output voltage. With a 4 to 1 turns ratio a 12 V output reflects 48 V, so a 48 V input puts 96 V across the drain at turn off, and a 2 to 1 ratio reflects 24 V for a 72 V total. The 60 V input rating of the controller is not the rating of the switch: the external MOSFET has to be chosen from the sum plus a margin for leakage inductance ringing, and a 100 V part is the minimum for a 48 V input at a 4 to 1 ratio. This is where a bill of materials that quotes the controller and omits the FET gets the voltage wrong.
Microamps of quiescent current in a 60 V controller
At 48 V the 390 microamps of active current is 18.7 mW, and a year at that current is 3.42 Ah, which is a real number for a product that keeps an isolated housekeeping rail alive. Sleep mode at 120 microamps is 1.05 Ah over a year. The 0.5 percent minimum load is the other half of the light load story: a 10 W converter needs 50 mW of load to stay in regulation, and below that the output rises until the burst mode catches it. A load that can disappear entirely needs a bleed resistor, and that resistor's current is part of the standby budget.
| Parameter | Published value | What it decides |
|---|---|---|
| Input range | 4.5 V to 60 V | 48 V telecom and 24 V industrial rails |
| Feedback | Primary side sensing, no opto | No third winding, one resistor sets VOUT |
| Gate drive | 8 V for an external NFET | Logic level FETs not required |
| Conduction mode | Quasi-resonant boundary at heavy load | Transformer must be specified for it |
| Minimum load | Below 0.5 percent of full output | 50 mW on a 10 W converter |
| Quiescent, active | 390 uA | 18.7 mW at 48 V, 3.42 Ah over a year |
| Quiescent, sleep | 120 uA | 1.05 Ah over a year |
| Drain voltage at 48 V in | 72 V at a 2 to 1 ratio, 96 V at 4 to 1 | 100 V FET is the minimum |
| Package | 6-lead TSOT-23 | Controller only, no integrated switch |
Does the part need a minimum load to stay in regulation?
Yes, below 0.5 percent of full output the burst mode lets the output rise between cycles, and the specification is written as a minimum load rather than as a regulation limit. A converter that feeds a circuit which can be entirely switched off needs a permanent bleed resistor, and that resistor has to be sized against the 0.5 percent figure and against the leakage of the output capacitor. For a 10 W converter at 12 V the bleed for 50 mW is 2.9 kilohms, drawing 4 mA, which is more than the controller's own sleep current and belongs in the standby table rather than in a footnote.
Why is this part easier to certify than an optocoupler supply?
Because the feedback path has no optocoupler. An optocoupler carries a current transfer ratio that falls with age and with temperature, and a supply that depends on it has to be qualified with the degradation in the loop, plus the isolation barrier has to be rated as part of the signal path. Sampling the primary waveform removes that component and its drift from the loop, leaving the transformer as the only isolation element, which is a magnetic part with a rating that does not change over life. The trade is that the transformer has to be specified for boundary mode and for the reflected voltage, so the magnetic part is no longer a commodity. Isolated and non-isolated supplies are compared on the power management cross reference, the lead time for a custom transformer is covered on the component lead time page, and the full category is the analog and mixed-signal index.
Request Quote — In Stock, 100% New & Original, Full Warranty