The LT8302ES8E#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8302ES8E#TRPBF: isolated 18 W without an optocoupler or a third winding
The LT8302ES8E#TRPBF is an Analog Devices micropower isolated flyback converter that regulates by sampling the isolated output voltage directly from the primary side flyback waveform. That removes the optocoupler and the transformer third winding that a conventional isolated supply needs. The input range is 3 V to 42 V, the internal DMOS switch is rated 3.6 A and 65 V, and the part delivers up to 18 W of isolated output. Quiescent current is 106 uA in sleep mode and 380 uA in active mode, it runs in quasi-resonant boundary mode at heavy load and low ripple burst mode at light load, and the minimum load is below 0.5 percent of full output. Output voltage is set by two external resistors plus an optional temperature compensation resistor for the output diode. The part is AEC-Q100 qualified and comes in a thermally enhanced 8-lead SO. It is on the analog and mixed-signal IC line card.
The missing optocoupler changes the error budget
Regulating from the primary waveform means the output voltage is inferred from the switch node, so the output diode forward drop and the transformer turns ratio are inside the regulation loop rather than outside it. The optional temperature compensation resistor exists precisely to cancel the diode drift. That is a different error budget from an optocoupler loop: there is no opto gain drift over life, which is the failure mode that makes isolated supplies age, but the diode and the transformer tolerance now matter directly. For most industrial and automotive rails the trade is favourable, and it removes an isolated feedback path that would otherwise need its own creepage.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Input range | 3 V to 42 V | 14 to 1 range, one part for 12 V and 24 V buses |
| Switch | 3.6 A, 65 V DMOS | 234 VA of switch rating |
| Output power | up to 18 W isolated | 1.5 A of input at 12 V before losses |
| Minimum load | under 0.5 percent typical | 90 mW at 18 W of full output |
| Sleep current | 106 uA | 1.27 mW at 12 V |
| Active current | 380 uA | 4.56 mW at 12 V |
| Qualification | AEC-Q100 | automotive grade on the order code |
Boundary mode is what keeps the transformer small
Quasi-resonant boundary mode runs the converter at the edge of continuous conduction, so the transformer does not have to store energy for a full cycle and the primary inductance can be smaller than a continuous mode part of the same power. At light load the part moves to low ripple burst mode, which keeps efficiency up and output ripple small at the same time, and that is unusual: most parts trade one for the other. The 0.5 percent minimum load figure is the point below which the burst behaviour changes, and it is 90 mW on an 18 W build.
Selection notes
- The transformer is still an external part and its turns ratio, leakage inductance and interwinding capacitance set the isolation and the EMI. The part removes the opto and the third winding, not the transformer.
- The temperature compensation resistor across the output diode is worth fitting on any board where the output voltage has to hold over temperature, because the diode drop is a large part of the error at low output voltages.
- Output short circuit protection is internal, which matters in an isolated rail that feeds a connector a user can touch.
- The 42 V input ceiling is the automotive load dump limit only with external protection; a 24 V truck system needs a clamp in front of the part.
Questions buyers ask
Does it really work without an optocoupler? Yes, the output voltage is sampled from the primary flyback waveform during the off time, and the regulation accuracy quoted in the datasheet includes that method.
Can it supply 18 W at 3 V in? The switch current limit is the constraint at low input voltage, so the available output power falls as the input falls. The 18 W figure belongs to the higher end of the input range.
Isolated rails for automotive and industrial equipment are quoted with the transformer, and delivery on allocated magnetic parts is under BOM shortage recovery. The wider regulator family is on the power management cross reference page.