LT4250HCS8#TRPBF
Product Specifications
LT4250HCS8#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT4250HCS8#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT4250HCS8#TRPBF: a negative 48 V hot swap controller with a 500 us fuse that resets itself
The LT4250HCS8#TRPBF is an Analog Devices negative 48 V hot swap controller in an 8-lead SO package. It operates from -18 V to -80 V, limits inrush current by controlling the gate of an external N-channel pass transistor, and turns that transistor off when the input falls below a programmable undervoltage threshold or rises above a programmable overvoltage threshold. A second programmable limit sets the short circuit current, and after a 500 us timeout the electronic circuit breaker latches the pass transistor off. The H version drives a module with a high enable input and the L version drives one with a low enable input; the two are otherwise the same part. The pinout is compatible with the LT1640L and LT1640H, and the on/off threshold is compatible with Bell-core requirements. It is on the analog and mixed-signal IC line card.
500 us is short for a fuse and long for a transistor
During a short at -48 V and 10 A the pass transistor carries 480 W, and 500 us of that is 240 mJ. At 2 A the same window is 48 mJ. The pass transistor has to absorb that energy inside its safe operating area, which is a different curve from its steady state current rating, and the gate voltage the controller applies decides how much of the rail appears across the device. A MOSFET chosen on current rating alone will survive the steady state and fail on the first short, which is the single most common fault in a first 48 V board.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Operating range | -18 V to -80 V | 4.4 to 1, covers 24 V, 48 V and 60 V plants |
| Breaker timeout | 500 us | 240 mJ at 48 V and 10 A, 48 mJ at 2 A |
| Limits | inrush and short circuit, both programmable | two separate resistors, two separate behaviours |
| Protection | undervoltage and overvoltage, programmable | set by dividers on the negative rail |
| Enable polarity | H drives a high enable, L a low enable | ordering the wrong suffix inverts the module state |
| Pinout | compatible with LT1640L and LT1640H | the part can be changed without touching the copper |
| Package | 8-lead SO and PDIP | the PDIP is for through hole retrofit work |
Negative rail control is not the same as positive rail control
On a -48 V plant the return is at zero and the live conductor is below it, so the pass transistor sits in the negative lead and its gate drive is referenced to the more negative node. The controller generates that offset internally, which is why the part works from a single negative supply and why the sense resistor goes in the negative lead as well. A hot swap controller built for a positive rail cannot be dropped into this position by changing the polarity of the divider, because the internal references and the gate drive are referenced the other way round.
Selection notes
- The overvoltage threshold protects the load from a wrong module being plugged into the same shelf, which happens in a mixed 24 V and 48 V installation.
- The inrush limit is set for the load capacitance, and a board with 1000 uF needs a longer charge time than the 500 us breaker window, so the two settings interact.
- Bell-core compatibility refers to the on/off threshold, which is a telecom requirement and not an optional feature.
- Latch-off after a fault means the board must be removed and reinserted, which is deliberate: a shorted board that retries forever heats the shelf.
Questions buyers ask
Can the H version replace the L version on an existing board? No. The enable polarity is inverted, so the module would be held off. The pinout is shared, the function is not.
Is a fuse still needed? The breaker protects the board from its own load. A fuse or a breaker upstream still protects the shelf from a failure of the pass transistor itself.
Hot swap controllers are a common substitution on telecom boards, and the checks are on how to verify a drop in replacement with the family on power management cross reference.
Request Quote — In Stock, 100% New & Original, Full Warranty