Contact Us

LT3799EMSE#TRPBF

Brand: Analog Devices
Analog Devices LT3799EMSE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3799EMSE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3799EMSE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3799EMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3799EMSE: TRIAC Dimming on an Isolated Flyback Without an Opto

The LT3799 is the LED member of the offline no-opto flyback family, and its distinguishing feature is that it dims from a TRIAC waveform without a separate dimming decoder. It runs in critical conduction mode from an offline rail, holds a power factor around 0.97, regulates secondary current from the primary side and reports open and shorted strings on a fault pin. The 16-lead MSOP package is rated 50 C/W, the junction limit is 125 C, and the thresholds that shape the transformer and the sense resistor are the 23 V turn-on point and the 100 mV current limit.

Published values

ParameterValue
Input turn-on voltage22.2 to 24.2 V, 23 V typical
Input turn-off voltage11.8 to 13.0 V, 12.3 V typical
Input hysteresis10.7 V typical, 46 percent of the turn-on point
Shunt regulator25 V, 15 mA current limit
Sense current limit threshold96 to 106 mV, 100 mV typical
Feedback threshold1.22 to 1.29 V, 1.25 V typical
Timer pin thresholds240 mV falling, 1.25 V rising
Oscillator range25 kHz minimum, 300 kHz maximum, 20 kHz backup
Current loop gain21 V per V
Quiescent current55 to 75 uA before turn-on
Junction limit125 C
Package and thermal16-lead MSOP with exposed pad, 50 C/W junction to ambient

The 10.7 V hysteresis is the start-up budget

The part turns on at 23 V and off at 12.3 V, a 10.7 V gap that is 46 percent of the turn-on point. That gap exists because the input rail collapses when the converter starts drawing current through the rectifier and the EMI filter, and a controller with a narrow hysteresis would oscillate between run and stop. In a TRIAC dimmer the rail also collapses at every conduction angle change, so the wide window is what keeps the converter running through the dimming waveform.

The 25 V shunt with a 15 mA limit sets the maximum current the start-up resistor has to deliver before the converter takes over. At 25 V and 15 mA that is 375 mW dissipated in the shunt path, which is why the start-up resistor is a high value part and why the third winding takes over as soon as the converter runs.

Setting current with 100 mV

A one amp string at the 100 mV limit needs 0.1 ohm and burns 100 mW; a 500 mA string needs 0.2 ohm and burns 50 mW. Because the part regulates secondary current from the primary side, the sense resistor is on the primary side of the barrier and the current it measures is the reflected secondary current, so the transformer turns ratio is part of the calibration. A transformer with the same turns ratio from a second source is fine; one with a different ratio is not, even if the footprint matches.

The current loop gain of 21 V per V is what turns 100 mV of sense into 2.1 V of control range, and that is high enough that the compensation sits on the COMP pins rather than inside the part. The CT pin charges at 10 uA and discharges at 200 nA, which is the arrangement that produces the timing ramp for critical conduction mode.

Critical conduction mode and the 25 kHz floor

Critical conduction mode means the inductor current returns to zero before the next cycle starts, so the transformer is sized for the energy per cycle rather than for continuous current. The 25 kHz minimum oscillator and the 20 kHz backup set the longest period the converter can produce, 40 us and 50 us, and those numbers size the transformer: at the bottom of the load range the converter must still complete a cycle within that period, so the magnetising inductance has a ceiling as well as a floor.

The fault pin reports open and shorted strings. An open string raises the output voltage until the feedback threshold is no longer met, and a shorted string pulls the current limit into a runaway, so both conditions are caught by watching the same two nodes the loop already uses.

Buyers usually arrive at the power management cross reference to find the family alternatives, then use the ADI second source page to confirm a substitute before it is fitted; component lead time solutions is the routine for a part that has already stopped shipping.

Two questions buyers ask

Does it need a separate TRIAC dimming circuit? The part is built to work from a TRIAC chopped input and has the timer and control pins for it, so the dimming information comes from the input waveform rather than from a decoded DC level. The external parts are the bleeder and the filter around the rectifier.

Can the same transformer be used with an LT3798? Only if the turns ratio and the leakage match the reference values for the secondary current sensing. The two parts sense current in the same way, so a transformer qualified for one is a candidate for the other, but the reflected current calibration has to be checked.