LT3763IFE#TRPBF
Product Specifications
LT3763IFE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3763IFE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3763IFE#TRPBF: the 125 C code of the 60 V, 20 A controller
LT3763IFE#TRPBF is the I grade of the same 60 V constant current controller, in the 28 lead TSSOP, on tape and reel. Everything the H grade page lists applies: 50 mV output current sense, 10 mV input current limit sense, a 2.00 V reference, a 1.206 V feedback threshold, and a 200 kHz to 1 MHz switching band. The I grade is guaranteed over minus 40 C to 125 C, which is the industrial envelope.
Published values
| Parameter | Value |
|---|---|
| Temperature grade | I, guaranteed minus 40 C to 125 C junction |
| Input voltage | up to 60 V |
| Current sense full scale | 50 mV, 46 mV to 54 mV |
| Input current limit sense | 10 mV, 6 mV to 14 mV |
| Voltage reference | 2.00 V |
| Feedback threshold | 1.206 V, 1.188 V to 1.224 V |
| Switching frequency | 200 kHz to 1 MHz |
| Quiescent current | 1.7 mA typical, 3.5 mA maximum |
| Package and thermal | 28 lead TSSOP, theta JA 30 C/W |
| Grade ladder | E and I to 125 C, H to 150 C |
Where the 125 C grade stops
The controller is not the hot part: at 60 V and 3.5 mA it dissipates 210 mW, a 6 C rise. The junction temperature that matters is inside the external FET and the sense resistor, and those are chosen by the board rather than by the order code.
So the I grade is the right order whenever the enclosure stays under 105 C and the FETs are sized with margin. Above that the H grade is the answer, and the difference in price is small against the cost of re-qualifying a board later.
Low side sensing and the ground it references
The current sense sits in the return path, so the sense resistor is between the LED string and ground and the controller reads 50 mV across it. That keeps the common mode at ground and lets the part work at any output voltage up to the 60 V ceiling of the switches.
The cost is that the load is no longer ground referenced. On a lamp that shares a chassis ground with the supply, the sense resistor has to go in the low side of the whole string and the chassis connection moves. That is a mechanical decision as much as an electrical one.
Frequency choice inside the band
Two hundred kilohertz to 1 MHz is a wide band and the choice is thermal. At 200 kHz the inductor is large and the switching loss is low; at 1 MHz the inductor is small and the FETs run hotter. On a 48 V to 12 V converter at 20 A the difference between the two is several watts of switching loss.
A useful rule for this part is to pick the lowest frequency the ripple target allows, because the sense resistor already costs 1 W at full load and the budget is not generous.
Sourcing notes for this family: the power management cross reference holds the cross references, medical device components is the pre substitution check, and how to reduce component cost is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask
Can the I grade be replaced by the H? Yes, and it is the safe direction. The reverse changes the guaranteed range, which matters if the enclosure runs above 105 C.
Is 20 A a controller limit? No. It is the external FET, inductor and sense resistor that set it; the controller only drives the gate and compares 50 mV.
LT3763IFE#TRPBF: The 60 V 20 A LED Controller, and What the Sense Voltage Decides
The LT3763IFE#TRPBF is the I grade of a 60 V synchronous step-down controller built to regulate current rather than voltage. It takes 6 V to 60 V input, holds output current regulation from 0 V to 55 V, and is quoted at up to 20 A of output current, which is a controller rating carried by the external MOSFETs, the inductor and the sense resistor rather than by the package. The I grade is guaranteed from minus 40 to plus 125 C, and the H code is the 150 C part.
The 51 mV sense voltage is the whole current setting
Output current is set by an analog voltage on the CTRL pins and an external sense resistor, with the regulation point at 51 mV typical between SENSE+ and SENSE minus, guaranteed between 48 mV and 54 mV. That is the plus or minus 6 percent current accuracy in the feature list. A 2.5 milliohm resistor therefore sets 20.4 A, and a 5 milliohm resistor sets 10.2 A. The resistor itself dissipates 1.02 W at 20 A, and its own tolerance and temperature coefficient sit on top of the 6 percent, so a 1 percent resistor with 50 ppm drift is not the limiting term but a 5 percent generic part is. Input current limit works the same way from a separate 10 mV threshold, which sets a much lower current for the same resistor value.
Duty cycle, off time and the 55 V ceiling
The minimum off time is 140 ns, which puts a hard ceiling on duty cycle as the switching frequency rises. At 1 MHz the maximum duty is about 86 percent, which on a 60 V input caps the output near 51.6 V before losses, so the 55 V output claim needs a lower frequency. A 91.7 percent duty, which is what 55 V from 60 V requires, needs a period of at least 1.68 microseconds, so the frequency has to stay at or below roughly 595 kHz. The minimum on time of 50 ns at the bottom gate and 55 ns at the top gate is the other end of the same limit and matters when the output is short and the loop is asking for near zero duty.
| Item | Published value | What it decides on a board |
|---|---|---|
| Input and output | 6 V to 60 V in, 0 V to 55 V out | String length and input transient margin |
| Current sense | 51 mV plus or minus 6 percent | Sense resistor value and its tolerance |
| Switching frequency | 200 kHz to 1 MHz, RT pin or SYNC | Inductor size against duty ceiling |
| Minimum off time | 140 ns | Highest usable frequency at 55 V out |
| Supply current | 1.7 mA not switching, 0.2 uA shutdown | Standby drain and enable behaviour |
The controller budget is small, the gate charge is not
The controller itself draws 1.7 mA typical and 3.5 mA maximum while not switching, and 0.2 uA in shutdown, which is negligible against the load. The real budget is gate drive: the internal VCC regulator holds 5 V and the drivers are specified at 2.2 ohm pull up and 1.3 ohm pull down, so the charge delivered to the external MOSFET gates every cycle is what sets the drive loss. Two FETs with 30 nC of gate charge each at 400 kHz is 24 mA of average drive current and about 0.12 W, and that number grows linearly with frequency, which is one reason the 200 kHz to 1 MHz range is not equally usable at both ends.
Thermal path through a 28-lead TSSOP
The FE package is a 28-lead TSSOP with an exposed pad published at 30 C per watt, and pin 29 must be soldered. The controller dissipates little, but the pad also carries the ground return for the gate drive loops, so its copper is part of the switching behaviour as well as the thermal path. A board that leaves the pad connected through a single via tends to show ground bounce on the current sense amplifier, which appears as current regulation error rather than as a thermal problem. Our power management cross reference page covers the controller comparison, the BOM shortage recovery page covers allocation problems, and incoming checks run through the incoming inspection plan.