LT3763EFE#TRPBF
Product Specifications
LT3763EFE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3763EFE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3763EFE: 50 mV of Sense Sets the Current on a 20 A LED Rail
The LT3763 is a fixed frequency synchronous step-down controller that regulates average inductor current rather than a fixed output voltage, which is why one part number covers a 6 V single string and a 55 V architectural array at up to 20 A. Two control pins carry the current setpoint, the FB pin carries the voltage loop and the overvoltage limit, and a separate amplifier watches input current. In the 28-lead FE package with its exposed pad the thermal resistance is 30 C/W, which is what makes a 20 A rail possible at all, and the numbers below are the ones that decide the shunt, the inductor and the heat spreader.
Published values
| Parameter | Value |
|---|---|
| Input voltage range | 6 V to 60 V, 60 V absolute maximum |
| Output voltage range | 0 V to 55 V |
| Output current | Up to 20 A, set by the shunt and CTRL |
| Current sense threshold | 46 mV minimum, 50 mV typical, 54 mV maximum |
| Input current limit threshold | 6 mV minimum, 10 mV typical, 14 mV maximum |
| Feedback regulation voltage | 1.188 to 1.224 V, 1.206 V typical |
| Reference output | 1.94 to 2.06 V, 2.00 V typical |
| Voltage regulation accuracy | 1.5 percent |
| Current regulation accuracy | 6 percent |
| Switching frequency | 200 kHz to 1 MHz, 1 MHz at RT equal 40 k |
| Quiescent current | 1.7 mA typical, 3.5 mA maximum at 60 V in |
| Shutdown current | 2 uA maximum |
| Package and thermal | 28-lead TSEXP, 30 C/W junction to ambient |
Fifty millivolts is the whole current loop
At the typical 50 mV threshold a 2.5 milliohm shunt carries 20 A and burns exactly 1 W, which is why the vendor front page application shows a 2.5 milliohm resistor next to a 20 A rating. Ten amps on the same shunt is only 25 mV, a quarter of full scale, so a rail that spends its life between 5 A and 10 A should move to 5 milliohm, where 10 A gives the full 50 mV and 0.5 W. The trade is resolution against loss: the 50 mV window is fixed, so a smaller shunt means more current per millivolt and a coarser setting for a light load.
The 6 percent current accuracy is a loop figure that includes the amplifier, the reference and the CTRL divider, but not the shunt. A 1 percent shunt spends a sixth of that budget on its own tolerance, and a 0.1 percent part spends a sixtieth. At 20 A the difference is 1.2 A against 120 mA of worst case error, which is the difference between a fixture that holds a bin and one that has to be trimmed in test.
The input current limit is a separate, lower threshold
The second amplifier watches the voltage across the input shunt with a 10 mV typical limit, so a 2 milliohm resistor on the input side trips at 5 A of input current while the output loop is still asking for more. That matters in a boost or buck stage fed from a current limited source: the input limit protects the source and the output loop protects the LEDs, and the two thresholds are deliberately not the same number. The input sense pins sit in a 12 V common mode window in the front page example, so the input shunt has to be placed where the amplifier can see it.
Read the two thresholds together before choosing the input shunt. Ten millivolts on 5 milliohm is 2 A, and a 2 A input limit on a 48 V feed is 96 W, which is the ceiling for the whole rail regardless of what the output loop wants. An engineer who copies the output shunt to the input side gets a limit five times higher than intended.
What 30 C/W means at 60 V of input
The controller alone draws 3.5 mA maximum at 60 V, which is 210 mW and a 6.3 C rise, and the 500 mW that a pair of shunts and a gate driver add is another 15 C. Both are comfortable. The real heat is the switch: at 60 V in and 6 V out the duty cycle is 10 percent, so at 1 MHz the top device is on for 100 ns of every microsecond, and the bottom device carries the inductor current for the other 900 ns. Its conduction loss at 2.2 milliohms and 20 A is 0.79 W during that time, averaged to 0.71 W, and that is a component choice rather than a controller choice.
The 55 V output ceiling and the 60 V input ceiling leave 5 V of headroom, which is the dropout plus the inductor and shunt drop at full current. A 60 V rail feeding a 55 V string therefore has no margin for supply tolerance, and the application examples put the input below 30 V for that reason.
Dimming, faults and the fixed frequency
True Color PWM dimming is quoted at 3000 to 1. At 300 Hz the shortest pulse in that range is 1.11 us and at 1 kHz it is 333 ns, both far below the current loop settling time at a 200 kHz switching frequency, so the useful dimming depth is set by how fast the loop recovers and not by the PWM driver. The PWM output pin is a driver, not a modulator: the pulse shape comes from the external signal and the part simply passes it through with the right level.
The FAULT comparator watches the FB pin against a 1.16 V upper and a 0.25 V lower threshold, which is 96 percent and 21 percent of the 1.206 V regulation point, and the overvoltage comparator trips at 1.515 V, 26 percent above regulation. Those three windows are what separate an open string from a shorted string in a system that cannot measure the output directly.
For a board that has to keep running while a reel runs out, the power management cross reference is where the family alternatives sit, the ADI second source page is the check list before a substitute goes in, and component lead time solutions is how a gap is covered without a new line item.
Two questions buyers ask
Can it run from a 48 V telecom rail? Yes, the input range is 6 V to 60 V and 48 V nominal with a plus or minus 10 percent window stays inside it. What changes is the duty cycle: 48 V to a 12 V string is 25 percent, which at 1 MHz is 250 ns of on time, comfortably above the minimum, while a 6 V string is 10 percent and 100 ns and starts to press against the minimum on time of the controller.
Is the sense resistor on the high side or the low side? The SENSE plus and SENSE minus pins are rated to 60 V absolute maximum, so a shunt in the return leg of a 55 V string keeps the amplifier near ground and is the easier of the two placements. Putting it in the high side works up to the 60 V pin rating and leaves no headroom at the top of the input range.