LT3748HMS#TRPBF
Product Specifications
LT3748HMS#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3748HMS#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3748HMS: A 150 C Junction With 90 C/W to Get Rid Of It
An isolated flyback controller that has to work at a 125 C ambient has a thermal problem before it has an electrical one. The LT3748H is guaranteed over minus 40 C to 150 C junction in the 16 lead MSOP, and that package is 90 C/W junction to ambient, which is more than twice the figure of the small buck controllers in the same catalogue. The consequence is simple: a 125 C ambient leaves 25 C of rise, which is 0.28 W for the whole controller, and the build has to be built around that number rather than around the electrical table.
Published values
| Parameter | Value |
|---|---|
| Input range | 5 V to 100 V |
| Guarantee | minus 40 C to 150 C junction, tested |
| Thermal resistance | 90 C/W junction to ambient |
| Budget at 125 C ambient | 0.28 W |
| Budget at 105 C ambient | 0.5 W |
| Gate drive | 1.9 A average, 16 ns edges into 3300 pF |
| Maximum sense threshold | 100 mV, overcurrent at 130 mV |
| Minimum gate off time | 700 ns |
| Internal gate supply | 7 V regulator, 3.6 V undervoltage lockout |
| Quiescent current | 1.3 mA typical, 1.75 mA maximum |
| Storage range | minus 65 C to 150 C |
| Automotive variants | I and H grades available with a W suffix |
0.28 W at 125 C ambient, and the quiescent current alone is 175 mW
At 100 V input and 1.75 mA maximum the controller burns 175 mW before it drives anything, which at 90 C/W is 15.8 C of rise. Add a 30 nC FET at 200 kHz, which is 6 mA of average gate current from the 7 V rail, and the total is 217 mW and 19.5 C, so a 125 C ambient puts the junction at 145 C. That is inside the guarantee and it is also inside the region where the datasheet says lifetime is derated, so the usable ambient for a long life build is nearer 105 C, where the same 217 mW leaves 48 C of margin.
The lever is the input voltage. At 48 V the quiescent term halves to 84 mW and the junction drops by 8 C for the same everything else, which is why the 36 V to 72 V telecom application is a better fit for this package than a 100 V industrial rail.
A 16 lead MSOP with four leads removed is a creepage decision
The package is a 16 lead MSOP with four leads removed to widen the spacing between the high voltage pins, and that is the reason a 100 V part fits in a body this small. It also means the footprint is not a standard 16 lead MSOP footprint: the missing leads and the wider pad spacing have to come from the package drawing, not from a generic library. A board built on the wrong footprint will pass at 25 V and fail a hipot test at 100 V, which is a slow and expensive way to find out.
The 90 C/W figure is for the package on a board with the exposed pad soldered down. Without that connection the thermal resistance is much higher and the 0.28 W budget disappears, so the pad is not optional on a high temperature build.
Where the H grade earns its price in an isolated supply
An isolated supply usually sits where the heat is: next to a transformer, inside a sealed box, or on the hot side of an enclosure that is already dissipating. The controller is the smallest dissipator in that box and it is also the part whose reference drift sets the output accuracy, so its junction temperature matters twice. The H grade is the only listing that keeps the electrical table valid at 150 C junction, and the W suffix adds the automotive screening for the same grades without changing the temperature range.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, defense grade components covers what to check before a part is dropped into an existing board, and one stop BOM sourcing is the route we take on a live shortage.
Two questions buyers ask
Is the H grade available with an automotive suffix? Yes, the I and H grades are listed with a W suffix for automotive use, and only those W models are released for automotive applications. The electrical table is the same; the difference is the controlled process and the reliability reporting behind it.
Can the converter run from a 100 V rail at 150 C junction? Electrically yes, thermally only at low gate charge and low switching frequency. At 100 V the quiescent current alone is 175 mW, which is 15.8 C of rise, so a 150 C junction leaves a narrow ambient window. A 48 V rail is the sensible pairing for this package.