LT3690MPUFE#TRPBF
Product Specifications
LT3690MPUFE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3690MPUFE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3690MPUFE: 36 V, 4 A step-down that has to start at minus 55 degrees
The LT3690MPUFE is the minus 55 to 150 degree junction grade of the LT3690 family: a 36 V input, 4 A synchronous step-down regulator in a 26-lead 4 mm by 6 mm QFN, with an internal 30 milliohm synchronous switch, an internal boost diode, a 0.8 V reference, a programmable 170 kHz to 1.5 MHz oscillator and 70 microamps of quiescent current in Burst Mode. It operates from 3.9 V and has an overvoltage lockout that protects the circuit through 60 V transients. The MP grade is the one that gets specified when the board has to keep regulating through a cold soak and a hot soak in the same qualification.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 3.9 V to 36 V, overvoltage lockout through 60 V transients |
| Output current | 4 A maximum |
| Output voltage | 0.8 V to 20 V set by the feedback divider |
| Reference | 0.8 V |
| Synchronous switch | 30 milliohm N-channel |
| High side current limit | 5.5 A minimum, 6.6 A typical, 8 A maximum |
| Low side current threshold | 4 A minimum, 5 A typical, 6.5 A maximum |
| Quiescent current | 70 microamps at 12 V in, 3.3 V out, Burst Mode |
| Shutdown current | under 1 microamp |
| Switching frequency | 170 kHz to 1.5 MHz, programmable and synchronizable |
| Minimum switch off time | 210 nanoseconds |
| Package | 26-lead, 4 mm by 6 mm QFN |
| Temperature grade | MP, junction from minus 55 to 150 degrees |
| Order code | LT3690MPUFE#TRPBF, tape and reel |
The inductor current decides whether 4 A is available
A 4 A output rating is only reached when the peak inductor current stays below the 5.5 A minimum high side limit. At 12 V in and 3.3 V out, an inductor chosen for 30 percent ripple at 500 kHz is 3.9 microhenry, which gives 1.2 A peak to peak and a peak current of 4.6 A. That leaves 0.9 A of margin against the worst case limit, and it is the margin, not the typical current limit of 6.6 A, that the arithmetic has to use.
At 36 V in the ripple triples for the same inductor and frequency, so the peak current arrives at the limit before the average does. That is why raising the frequency helps at high input voltage, and why the 210 nanosecond minimum off time sets the practical ceiling: a 36 V to 0.8 V conversion at 1.5 MHz needs an on time of about 20 nanoseconds, so the frequency has to come down or the inductor has to grow.
Starting at minus 55 degrees
The fixed undervoltage lockout is 3.0 V minimum and 3.9 V maximum, which means the guaranteed start is at 3.9 V and the part will not run below 3.0 V. In a cold soak the input source impedance is usually worse, so a rail that sags as the load comes on can sit between those two numbers and cause a start that never completes. Checking the divider on the UVLO pin against the cold load line is the step that catches it.
The reference is 0.8 V at 25 degrees and moves with temperature, so the output voltage moves with it. For a 3.3 V rail the divider is a ratio of 3.125, and a reference that drifts by a fraction of a percent over 205 degrees of specified range takes the output with it. A rail that has to hold a tight tolerance at both temperature extremes is better regulated by a divider with a low temperature coefficient than by any adjustment made on the bench.
Why the MP grade rather than the H or the I
The family spans three temperature ranges in the order table: the E and I grades from minus 40 to 125 degrees, the H grade from minus 40 to 150 degrees, and the MP grade from minus 55 to 150 degrees. Only the MP covers a genuine cold soak below minus 40 and only the H and MP cover a 150 degree junction.
Paying for MP when minus 40 would do is a common over specification, and refusing to pay for it when the qualification includes a cold start is a common under specification. The deciding question is not the ambient range of the product but the temperature the junction reaches during a fault, because a 4 A regulator with a shorted output will run at its thermal limit until the foldback or the thermal shutdown acts.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, component lead time solutions covers what to check before a part is dropped into an existing board, and OEM procurement is the route we take on a live shortage.
Two questions buyers ask
Is the 4 A output available at 36 V input? It is available as long as the inductor peak current stays under the 5.5 A minimum high side limit. At 36 V in the ripple for a given inductor is about three times what it is at 12 V, so the inductance or the switching frequency has to change to keep the margin.
What is the difference between the MP and the H grade? The MP covers minus 55 to 150 degrees junction and the H covers minus 40 to 150. Both reach the same hot end; only the MP is specified below minus 40.