LT3060HTS8#TRPBF
Product Specifications
LT3060HTS8#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3060HTS8#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3060HTS8#TRPBF: adjustable 45 V input regulator tested to 150 C
The LT3060HTS8#TRPBF is the adjustable LT3060 in the 8-lead ThinSOT, tape and reel, H grade, guaranteed from minus 40 C to 150 C at the junction. The 600 mV reference and an external divider set any output up to 44.5 V, the input range is 1.6 V to 45 V, and the part carries 100 mA with 40 uA of quiescent current. In a hot enclosure it is the code that lets a non standard output voltage keep the same temperature claim as the fixed codes, which is why it turns up on rails such as 4.2 V, 6 V or 12 V in sealed equipment.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 1.6 V to 45 V, 50 V absolute maximum |
| Reference voltage | 600 mV, 585 mV to 612 mV over temperature, H and MP grades |
| Output range | 600 mV to 44.5 V |
| Output current | 100 mA, current limit with foldback |
| Line regulation | 0.6 mV typical, 4 mV maximum, H grade |
| Load regulation | 0.2 mV typical, 9 mV maximum, H grade |
| ADJ pin bias current | 15 nA typical, 60 nA maximum, out of the pin |
| Quiescent current | 40 uA typical, below 1 uA in shutdown |
| Package | 8-lead ThinSOT, part marking LTDTF |
| Thermal resistance | 57 C/W to 67 C/W junction to ambient, 25 C/W to case |
| Maximum junction | 150 C, thermal shutdown at about 165 C |
| Grade | H, minus 40 C to 150 C |
The reference drift and the divider
The reference is specified over the whole 150 C window at 585 mV to 612 mV, a 4.5 percent spread that is wider than the 25 C figure and wider than the I grade. Because the output is the reference multiplied by the divider ratio, that spread scales with the output: a 600 mV output moves by 27 mV and a 12 V output moves by 540 mV. That is the arithmetic that decides whether an adjustable output at high temperature needs a trim, and it is also the reason the fixed codes exist, since their internal divider is trimmed on the die. The ADJ pin bias current of 15 nA typical flows out of the pin and adds to the bottom resistor current, so the divider has to stay near 10 uA for the error to remain a few millivolts.
Hot start behaviour
The REF/BYP capacitor does double duty: it sets the noise floor at 30 uV RMS with 10 nF, and it sets the soft start ramp. In shutdown it is discharged, so the ramp is the same on every enable. That matters in equipment that cycles power in a hot enclosure, because a capacitor that has been sitting at 120 C has a different value from one at room temperature and the ramp would otherwise vary with the thermal history. The internal protection is current limit with foldback on input to output differential, plus thermal shutdown at about 165 C, plus reverse input, reverse output and reverse output to input protection, so a hot board that sees a fault is protected on all three paths rather than on current alone.
Choosing between H and MP for the cold end
Both grades reach 150 C. The difference is the cold end: H is guaranteed from minus 40 C and MP from minus 55 C, and the MP part is tested over the full minus 55 C to 150 C window rather than tested at temperature. A 15 C difference at the bottom of the range is the entire distinction, and it is worth paying for only where the equipment is genuinely exposed to minus 40 C or below, such as an outdoor cabinet at altitude. Everywhere else the H code is the cheaper way to buy the 150 C hot end.
Where the adjustable H code fits
This code covers the odd output voltages at the high temperature end of the family, alongside the seven fixed options and the DFN body with its automotive variants. The temperature grades, bodies and markings are tabulated on the power management cross reference, the shortage route for a single line item is BOM shortage recovery, and the case for consolidating several ADI rails under one supplier is made on one stop BOM sourcing.