Contact Us

HMC8415

Brand: Analog Devices
Analog Devices HMC8415 is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HMC8415 — Analog & Mixed-Signal ICs | Superb Automation

HMC8415

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The HMC8415 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

HMC8415LP6GE: 40 W pulsed at 9 GHz to 10.5 GHz, and the 1 A that is not the operating current

The HMC8415LP6GE is a gallium nitride power amplifier in a 6 mm x 6 mm 40-lead LFCSP that delivers 40 W, or 46 dBm, over 9 GHz to 10.5 GHz from a 28 V drain supply with a target quiescent current of 1000 mA. It is specified for pulsed radar duty cycles, and the single most expensive mistake in a first board is to read the 1000 mA as the current the supply has to deliver while the pulse is on.

Published values

ParameterValue
Frequency range9 GHz to 10.5 GHz
Output power at 23 dBm input, 9 to 10 GHz46 dBm typical
Output power at 21 dBm input, 9 to 10 GHz45 dBm typical
Small signal gain, 9 to 10 GHz30 dB minimum, 32.5 dB typical
Power gain at 23 dBm input, 9 to 10 GHz23 dB typical
Small signal gain, 10 to 10.5 GHz25.5 dB minimum, 28 dB typical
Output power at 23 dBm input, 10 to 10.5 GHz45 dBm typical
Power added efficiency at 23 dBm input40% typical, 9 to 10 GHz
Power added efficiency at 23 dBm input37.5% typical, 10 to 10.5 GHz
Drain supply28 V nominal, 35 V absolute maximum
Gate supply-4.0 V to -1.5 V to set 1000 mA, -2.5 V typical
Quiescent current1000 mA target
Input drive, absolute maximum30 dBm
Pulse width, absolute maximum500 us
Package40-lead LFCSP, 6 mm x 6 mm

The current during the pulse

40 W of radio frequency at 40 percent power added efficiency implies 100 W of dc input during the pulse. At 28 V that is 3.57 A, not 1 A. The 1000 mA is the quiescent current with no drive, which is the number the bias sequence is set against, and the drain supply and its decoupling have to be sized for the driven current.

The efficiency figures are published at a 100 microsecond pulse width and 10 percent duty cycle, so the average dissipation on the die is far lower than the instantaneous figure. That is why a 6 mm x 6 mm package can carry the part at all. A supply sized for the average current, rather than for the pulse current, will sag during the pulse and the output will follow it down.

Bias sequencing, which is the failure mode

The gate must be set before the drain is applied and removed after the drain is removed, so the bias circuit is a sequencer and not a pair of regulators. The gate range that achieves 1000 mA is published as -4.0 V to -1.5 V with -2.5 V typical, which is a wide spread and tells you that the setting is per part rather than per board.

The absolute maximum gate voltage is -1 V, so a gate supply that loses its reference and floats to 0 V destroys the part. A clamp on the gate rail and a sequenced enable are both cheap, and a programme that omits either usually discovers the cost on the second build rather than the first.

Gain compression across the band

Small signal gain is 32.5 dB from 9 GHz to 10 GHz and 28 dB from 10 GHz to 10.5 GHz, while the power gain at 23 dBm input is 23 dB. The 9.5 dB difference is the compression the part is driven to run at, and it means the driver stage has to deliver 23 dBm into this part at the top of the band with a known level.

The 2 dB input return loss figure at the top of the band is a reminder that the input match is not constant. A driver with a fixed output match will see a different load above 10 GHz, and the delivered power will move with it. In a radar front end this is usually absorbed by an isolator, at the cost of its loss in the same path.

Thermal and mechanical

A 40-lead LFCSP at 6 mm x 6 mm passes heat through its exposed paddle into the board, and the thermal resistance table is junction to case. A pulsed application is easier on the die than the average power suggests, but the average power still comes from the duty cycle, and a 20 percent duty cycle doubles it against the published condition.

The vendor publishes a bias pulsor board and a recommended sequence, and both are worth copying rather than reinventing. The pulsor also protects the part during a fault, because it removes the drain when the pulse train stops.

Buyers usually arrive at the amplifier cross reference to find the family alternatives, then use defense grade components to confirm a substitute before it is fitted; one stop BOM sourcing is the routine for a part that has already stopped shipping.

Two questions buyers ask

Does the HMC8415LP6GE need 3.57 A from the 28 V supply? During a pulse at full drive, the dc input implied by 40 W output at 40 percent efficiency is about 3.57 A. The 1000 mA in the specification is the quiescent current without drive, and the supply has to be sized for the pulse current and its duty cycle.

Can it be run continuous wave? The published conditions are a 100 microsecond pulse at 10 percent duty cycle, and the absolute maximum pulse width is 500 microseconds. A continuous wave requirement should be discussed against the thermal data rather than assumed from the saturated power figure.