HMC1126
Product Specifications
HMC1126
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The HMC1126 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HMC1126: 2 GHz to 50 GHz, 65 mA and one supply pin with a choke inside
The HMC1126 is a gallium arsenide pHEMT distributed amplifier die covering 2 GHz to 50 GHz with 11 dB of gain at the bottom of the band and 10.5 dB at the top, 17.5 dBm at one decibel compression to 26 GHz, 21 dBm saturated, 31 dBm of output third order intercept and 4.5 dB of noise figure, from 65 mA at 5 V. The die is 2.3 mm by 1.45 mm by 0.05 mm and the power supply pin has the radio frequency choke integrated, which is the detail that makes this part easy to bias and hard to decouple badly.
Published values
| Parameter | Value |
|---|---|
| Frequency range | 2 GHz to 50 GHz, four specified bands |
| Gain | 11 dB typical 2 to 10 GHz, 10.5 dB 10 to 26 GHz and 26 to 40 GHz, 10.5 dB 40 to 50 GHz |
| Gain variation over temperature | 0.002 to 0.009 dB per degree |
| Noise figure | 4.5 dB, 4.0 dB, 4.0 dB and 5.0 dB across the four bands |
| Input return loss | 12 dB, 14 dB, 20 dB and 12 dB |
| Output return loss | 14 dB, 20 dB, 18 dB and 12 dB |
| Output power at 1 dB compression | 17.5 dBm, 17.5 dBm, 16 dBm and 13 dBm |
| Saturated output power | 21 dBm, 21 dBm, 20.5 dBm and 18 dBm |
| Output third order intercept | 31 dBm, 28 dBm, 28 dBm and 24 dBm at 10 dBm per tone |
| Supply | 65 mA at any drain voltage from 4 V to 8 V, 8.5 V absolute maximum |
| Gate bias | VGG2 at 1.4 V, VGG1 adjusted for 65 mA |
| Die size | 2.3 mm by 1.45 mm by 0.05 mm |
| Thermal resistance | 47 degrees per watt channel to die bottom |
| Dissipation | 1.915 W at an 85 degree base, derate 21.3 mW per degree |
Sixty five milliamps at any voltage from 4 V to 8 V
The supply is a current sink, not a voltage load, and the vendor specifies 65 mA for every drain voltage from 4 V to 8 V. That is unusual and it is useful: the part can sit on a 5 V rail in one system and a 7 V rail in another with the same current and the same gain, and only the dissipation changes, from 0.26 W at 4 V to 0.52 W at 8 V. The bias network therefore does not need to be rescaled between platforms.
The catch is that 8 V of drain with 65 mA is 0.52 W in a die that is 3.3 square millimetres, and the vendor derating of 21.3 mW per degree above 85 degrees implies a 1.915 W ceiling that is never approached in normal operation. Running at 8 V buys nothing in radio frequency terms and doubles the heat, so the sensible choice is the lowest rail available, which in most systems is 5 V.
An integrated choke means the decoupling is the whole bias network
With the choke on chip, the external bias network is a capacitor and nothing else. That makes the part simple to use and puts all of the low frequency behaviour in the capacitor. Too small a capacitor and the envelope of a modulated signal appears on the drain; too large and the bias network rings with the choke at a low frequency where the amplifier has gain and no isolation.
The practical answer is a small capacitor close to the pad plus a larger one behind a series resistor or an inductor, which damps the resonance between the on chip choke and the external capacitance. The value pair is not critical at 65 mA, but a build that fits a single 100 nanofarad capacitor and calls it decoupled will see the supply modulation appear as gain ripple on a wideband signal, and that reads as a linearity problem rather than as a bias problem.
Bands where the part is a driver and bands where it is a pre driver
The compression point falls from 17.5 dBm to 13 dBm between 26 GHz and 50 GHz, and the intercept from 31 dBm to 24 dBm, so the same part is a 20 dBm class driver at the bottom of the band and a 13 dBm stage at the top. A system that uses it across the whole range has to size the following stage on the top band, and the 50 GHz end is where a 24 dBm intercept limits the spurious free range.
That split is not unusual for a distributed amplifier, and it is the reason the vendor specifies four bands instead of one. A buyer comparing two parts on a single gain number will not see it, which is why the band by band table is the only fair comparison and why the department of the system that operates above 40 GHz should be asked before the part is chosen on a low band specification.
Two pages worth reading before a purchase order goes out are the RF component sourcing page and how to choose an RF amplifier; the first lists what else fits the socket, the second is the test sequence for a drop in, and component lead time solutions covers the case where the shortage is already on the line.
Two questions buyers ask
What drain voltage should be used? Any voltage from 4 V to 8 V gives the same 65 mA and the same gain. The lowest rail in the system is the right choice, because the dissipation doubles between 4 V and 8 V and the radio frequency performance does not.
Does the part need a negative supply? VGG1 is adjusted between minus 2 V and 0 V to reach 65 mA and VGG2 sits at 1.4 V, so a gate reference below the source is needed and has to be applied before the drain.