ADXL212AEZ
Product Specifications
ADXL212AEZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADXL212AEZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADXL212AEZ: a dual axis 2 g accelerometer with a pulse width output and 1 mg of resolution at 60 Hz
The ADXL212AEZ is an Analog Devices dual axis accelerometer with a plus and minus 2 g range, a duty cycle modulated digital output and a 5 mm by 5 mm by 2 mm hermetic LCC package. Resolution is 1 mg at a 60 Hz bandwidth, the noise floor is 110 ug per root hertz, the supply current is 700 uA at 5 V typical, and the bandwidth is set from 0.5 Hz to 2.5 kHz with a single capacitor per axis. It measures both dynamic acceleration such as vibration and static acceleration such as gravity, survives 3500 g of shock, and is specified from -40 C to +125 C with high zero g bias stability and sensitivity accuracy over that range. Analog Devices marks the part as not recommended for new builds. It is listed on the analog and mixed-signal IC line card.
1 mg at 60 Hz is 0.057 degrees of tilt, and the noise decides whether that is reachable
One milligram of tilt is a simple calculation: the arcsine of 0.001 g over 1 g is 0.0573 degrees. The question is whether the part can resolve it. The noise density of 110 ug per root hertz integrated over a 60 Hz band gives 852 ug, so 1 mg is only 1.17 times the noise, which means a single reading cannot resolve it and averaging is required. Over the full 2.5 kHz bandwidth the same density gives 5.5 mg, five times the figure on the front page. That is the honest reading of a 1 mg resolution claim: it is a 60 Hz statement about a narrow band, and any application that widens the band loses resolution in proportion to the square root of the bandwidth.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Range and axes | plus and minus 2 g, two axes | 12 bits of span at a 1 mg step |
| Resolution | 1 mg at 60 Hz | 0.0573 degrees of tilt |
| Noise density | 110 ug per root hertz | 852 ug over 60 Hz, 5.5 mg over 2.5 kHz |
| Bandwidth | 0.5 Hz to 2.5 kHz, one capacitor per axis | a 0.5 Hz setting averages over two seconds |
| Output | duty cycle modulated, digital | a timer measures the ratio, no converter needed |
| Duty resolution needed | 1 mg of 2 g full scale | 0.05 percent of the period |
| Supply current | 700 uA at 5 V typical | 3.5 mW for both axes |
| Shock survival | 3500 g | an unpowered drop is inside the rating |
| Package | 5 mm by 5 mm by 2 mm hermetic LCC | sealed, and solderable with lead free or tin lead |
| Status | not recommended for new builds | in production, replacement demand only |
A duty cycle output removes the converter and adds a timing requirement
The output is a square wave whose duty cycle is proportional to acceleration, so the measurement is a timer capture rather than an analog to digital conversion. That is attractive in a system that already has a microcontroller with a capture unit: no reference, no analog front end, no calibration of an analog path. The requirement moves to the timer. Resolving 1 mg of a 2 g range needs 0.05 percent of the period, which is a 5 ns resolution on a 10 us period, well inside what a 100 MHz timer with a prescaler can do but outside what a slow 8-bit timer can. The other consequence is that the reading is an average over the measurement window, so a short acceleration event is integrated rather than sampled.
Zero g bias stability is the specification that decides a tilt sensor
A tilt sensor reads gravity, and the offset of the accelerometer at zero g becomes an angle error. High zero g bias stability over temperature is what allows a levelling product to be calibrated once. The part is specified over -40 C to +125 C with high sensitivity accuracy across that range, which is a wider window than most consumer accelerometers offer and is the reason it is found in automotive and industrial tilt applications. The 3500 g shock survival covers the drop that happens during installation, which is the failure mode that kills a sensor before it ever reports a measurement.
Selection notes
- The bandwidth capacitor is the resolution control: a smaller capacitor widens the band and loses resolution in proportion to the square root of the bandwidth.
- Two axes in one package share a supply and a timing reference, so the angle between them is fixed by the package rather than by assembly.
- The hermetic LCC is the right body for an environment with moisture or a wash, which is where a plastic package fails.
- For a new board the current families offer digital interfaces and lower noise; this part is the replacement for an installed base.
Questions buyers ask
Can it really resolve 1 mg? At a 60 Hz bandwidth, 1 mg is 1.17 times the integrated noise, so it needs averaging. At the full 2.5 kHz bandwidth the noise is 5.5 mg and 1 mg is not measurable.
Does the digital output need an analog reference? No. The duty cycle carries the information and a timer measures it, so the accuracy depends on the timer clock and not on a reference voltage.
Sensor front ends are grouped in medical device components, and replacement parts for installed equipment are covered under how to verify a drop in replacement.
Request Quote — In Stock, 100% New & Original, Full Warranty