ADXL203CE-REEL
Product Specifications
ADXL203CE-REEL
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADXL203CE-REEL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADXL203CE-REEL: two axes on one die, aligned to 0.1 degree, for the same 700 uA
The ADXL203CE-REEL is the dual axis member of the Analog Devices precision accelerometer family, in the same 5 mm by 5 mm by 2 mm 8-terminal ceramic LCC package as the single axis part. Both channels cover plus or minus 1.7 g, plus or minus 5 g or plus or minus 18 g depending on the order code, with a signal conditioned analog output, a noise density of 110 ug per root hertz typical, and 1 mg of resolution at 60 Hz. Each channel has its own bandwidth capacitor, adjustable from 0.5 Hz to 2.5 kHz, and the two axes are aligned to within 0.1 degree typical because they are on the same die. Supply current is 700 uA at 5 V for the pair, the part is specified from -40 C to +125 C, and it survives 3500 g of shock. It is on the analog and mixed-signal IC line card.
Two axes in one package remove an error that no calibration removes
Two single axis parts mounted at right angles carry a mechanical alignment error that comes from the pick and place machine, the solder reflow and the board's own warp. A tenth of a degree sounds small until it is converted: at 1 g, 0.1 degree of misalignment is 1.75 mg of signal appearing on the axis that should read zero. That is nearly twice the 1 mg resolution of the part and it is a systematic error that changes with temperature as the board flexes. Putting both axes on one die makes the orthogonality the vendor's specification rather than the assembly's, and 0.1 degree typical is the number that appears in the tilt calculation.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Axes | two, X and Y on one die | orthogonality within 0.1 degree typical |
| Cross axis error at 1 g | from the alignment figure | 1.75 mg on the axis that should read zero |
| Ranges | plus or minus 1.7 g, 5 g, 18 g | fixed by order code |
| Noise density | 110 ug per root hertz | 0.852 mg over 60 Hz per axis |
| Resolution | 1 mg at 60 Hz | 0.0573 degrees of tilt |
| Supply current | 700 uA at 5 V, both channels | 3.5 mW, half the cost of two single axis parts |
| Bandwidth | 0.5 Hz to 2.5 kHz per channel | one capacitor per axis |
| Shock | 3500 g survival | a survival figure, not a measurement range |
| Temperature | -40 C to +125 C | the same window as the single axis part |
Seven hundred microamps for both channels is the reason to use the dual
Two single axis parts would draw 1.4 mA and take twice the board area, before the alignment question is even raised. The dual draws 700 uA, which in a 4 mA to 20 mA loop powered transmitter is 17.5 percent of the entire budget. That arithmetic, rather than the price of the package, is what usually decides between the two options.
Selection notes
- A two axis tilt sensor needs both channels in the same thermal environment, which the single package provides and two separate parts do not.
- Each axis has its own bandwidth capacitor, so the board can filter the noisier axis harder without changing the other.
- The 18 g order code is the one for abuse detection, where the 1.7 g part would clip long before the event finished.
- For a third axis, the same family's three axis digital parts put a converter behind the sensing element and remove the analog routing.
Questions buyers ask
Does the 0.1 degree alignment apply over temperature? It is a typical figure at room, and the two axes are on one die, so the tracking over temperature is far better than two separate packages could achieve.
Can the two axes be sampled by one converter? Yes through a two channel multiplexer, and because both outputs are analog and low impedance the sampling order does not matter.
Accelerometer replacements are compared on pin to pin cross reference, and the parts held for diagnostic and patient handling equipment are under medical device components.
Request Quote — In Stock, 100% New & Original, Full Warranty