Contact Us

ADP2442ACPZ-R7

Brand: Analog Devices
Analog Devices ADP2442ACPZ-R7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADP2442ACPZ-R7 — Analog & Mixed-Signal ICs | Superb Automation

ADP2442ACPZ-R7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADP2442ACPZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADP2442ACPZ-R7: A 36 V Input Buck Whose 50 ns On Time Sets the Output Floor

The ADP2442 is a synchronous step-down regulator rated 4.5 V to 36 V in and 1 A out, with the power switch and the synchronous rectifier integrated. Switching frequency is adjustable from 300 kHz to 1 MHz and can be locked to an external clock over the same range. Output is adjustable down to 0.6 V with 1 percent accuracy, and the ACPZ code is the LFCSP body.

The duty cycle arithmetic, at three rails

At 24 V in and 5 V out the duty cycle is 20.8 percent, so at 1 MHz the switch is on for 208 ns, well above the 50 ns minimum. At 36 V in and 3.3 V out the duty falls to 9.2 percent and the on time to 92 ns. At 36 V in and 1.2 V out the duty is 3.3 percent, below the 5 percent floor the 50 ns minimum imposes at 1 MHz, so the part cannot hold regulation there without dropping the frequency. That floor is 1.8 V at 36 V in and 1 MHz, and it is the single most useful number when a customer wants a 1.2 V core rail from a 36 V bus.

The published table, as the vendor states it

ParameterValue
Input range4.5 V to 36 V
Output current1 A maximum
Output rangeadjustable down to 0.6 V, 1 percent accuracy
Switching frequency300 kHz to 1 MHz adjustable, external sync over the same range
Minimum on time50 ns typical
Efficiencyup to 94 percent
Light load modespulse skip or forced fixed frequency
Controlcurrent mode PWM, precision enable, open drain power good
PackageLFCSP

Loss at 24 V to 5 V, computed from the 94 percent figure

One ampere at 5 V is 5 W out; at 94 percent the input is 5.32 W, so 0.319 W is lost in the package and the inductor. At 36 V to 3.3 V the loss is 0.211 W, and at 12 V to 1.2 V it is 0.077 W. The 36 V rating does not cost efficiency in the way a linear pre regulator would, and the difference is what allows a 24 V industrial bus to feed logic directly.

Forced frequency against pulse skip

Pulse skip raises efficiency at light load by dropping cycles, which puts an audible or measurable low frequency component on the rail. Forced fixed frequency keeps the ripple at the switching frequency at the cost of quiescent loss. An analogue rail that feeds a converter usually wants forced mode; a standby rail on a battery wants pulse skip, and the mode pin is the same on both.

Buyer questions

Can the switching frequency be synchronised to the system clock? Yes, the SYNC input accepts an external clock from 300 kHz to 1 MHz, which keeps the switching fundamental away from a measurement band instead of leaving it wherever the internal oscillator lands.

What happens below the minimum on time? The regulator cannot shorten the pulse further, so the output rises above the set point or the loop drops cycles. If a customer needs 1.2 V from 36 V, the frequency has to come down before the rail can be regulated.

Category page: Analog and mixed-signal ICs. Regulator equivalents sit under power management cross reference; multi-line sourcing is covered in BOM shortage recovery.

Request Quote — In Stock, 100% New & Original, Full Warranty