ADN8834ACPZ-R7
Product Specifications
ADN8834ACPZ-R7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADN8834ACPZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADN8834ACPZ-R7: One Inductor, 2 MHz Switching and the Setpoint Error Nobody Budgets
The ADN8834ACPZ-R7 is a complete thermoelectric cooler controller in a 4 mm by 4 mm LFCSP. It carries a linear power stage, a 2.0 MHz pulse width modulated stage, an H-bridge with integrated low resistance MOSFETs and two zero drift chopper amplifiers that close the thermal loop as a proportional integral derivative compensator. For a laser diode or an optical filter that has to sit within a fraction of a degree, this is the block that decides whether the wavelength stays on channel.
The reference, not the loop, sets the first error term
The internal reference is 2.50 V with 1 percent accuracy, and it biases the thermistor bridge as well as the divider that programs the maximum TEC voltage and the heating and cooling current limits. One percent of 2.50 V is 25 mV. A 10 kohm negative temperature coefficient thermistor of the usual kind moves about 4.4 percent per degree near room temperature, so 1 percent of excitation is roughly 0.23 degrees of setpoint error before the thermistor tolerance, the divider resistors and the amplifier offset are counted. Buyers who compare only the controller and ignore the bridge parts usually find the last 0.2 degrees sitting in two 1 percent resistors.
What the published figures convert to
| Parameter | Published figure | What it means on a board |
|---|---|---|
| Switching frequency | 2.0 MHz | 500 ns period, so ripple is set by the inductor, not by the loop bandwidth |
| Ripple with 1 uH at 5 V, 50 percent duty | 0.625 A | Ripple current equals 62.5 percent of a 1 A load, so the inductor tolerance matters more than its nominal value |
| Reference | 2.50 V, 1 percent | 25 mV of bridge excitation error, about 0.23 degrees with a 4.4 percent per degree sensor |
| Bridge current at 2.5 V and 10 kohm | 0.25 mA | Small enough that self heating in the thermistor stays out of the error budget |
| Amplifiers | Two zero drift, rail to rail chopper | Offset drift does not appear as a slow setpoint walk over a 10 year life |
| Current limits | Independent heat and cool | Protects a TEC whose cooling current rating is lower than its heating rating |
| TEC voltage limit | Programmable | Stops the loop from demanding more than the module can take during a cold start |
| Monitoring | TEC voltage and current outputs | Both loop variables are observable without an external sense resistor |
| Sensor support | NTC thermistor or RTD | One board can serve two sensor families without a change of silicon |
| Lock indicator | Temperature lock output | Gives a digital in tolerance signal for a host or a front panel LED |
| Package | 24 lead LFCSP 4 mm by 4 mm or 25 ball WLCSP 2.5 mm | The WLCSP is the option when the module is a pluggable optical part |
| Qualification | AEC-Q100 | Relevant when the same module family is sold into automotive lidar |
Checks before accepting a cross reference
- Confirm whether the candidate part uses one inductor or two. A two inductor part will not fit the same footprint and will not have the same ripple.
- Compare the maximum TEC current limit range, not just the headline current. A part that limits at a fixed value cannot be trimmed to a smaller module.
- Check that both heating and cooling limits are programmable. Single limit parts force an external network that drifts.
- Ask for the lock indicator threshold behaviour. Latching and non latching outputs are not interchangeable in a host firmware that polls the pin.
- Verify the sensor type supported on the actual revision, since the RTD option is what allows a 100 ohm platinum sensor on a board that was qualified with a thermistor.
Where this part is used
Optical transceiver modules, erbium doped fibre amplifiers, tuneable lasers, Raman pump sources, precision reference ovens and any instrument where a small mass has to hold a temperature while the ambient moves. In these systems the controller sits next to the laser and the loop is entirely analog, so the part has to work without firmware intervention and without a microcontroller in the path.
Questions buyers ask
Does the part need an external sense resistor? No. The TEC current is monitored internally and brought out as a voltage, which removes one of the larger drift terms in a discrete implementation.
Can it drive a module rated below the standard current? The maximum TEC voltage and the two current limits are set by resistor dividers, so a smaller module is programmed down rather than replaced.
How long is the lead time risk? The LFCSP and WLCSP versions are separate order codes with separate reel options, so a shortage on one does not always block the other.
Sourcing notes and next step
The family page for these converters is the analog and mixed signal index, and modules that combine a controller with an optical assembly usually need the wider supply chain view in the medical and optical device sourcing page. When a build is short of this exact order code, the drop in replacement verification guide sets out which parameters have to match before a substitute is accepted. Send the target temperature, the TEC current, the sensor type and the annual quantity and we will quote from stock or from a bonded lot with the date code stated up front.
Request Quote — In Stock, 100% New & Original, Full Warranty