The ADM2491EBRWZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADM2491EBRWZ: reinforced isolation at sixteen megabit
The ADM2491EBRWZ is an isolated RS-485 and RS-422 transceiver with a 5000 V rms UL recognised rating, a reinforced working voltage of 849 V peak, 8 kV human body model protection on the bus pins and a 16 Mbps data rate. It is configurable as half or full duplex, which makes it the part for a four wire isolated link rather than a two wire field bus.
Published values
| Parameter | Value |
|---|---|
| Function | isolated RS-485 and RS-422, half or full duplex |
| Data rate | 16 Mbps |
| Isolation | 5000 V rms, UL recognised, reinforced |
| Working voltage | 849 V peak |
| ESD on bus pins | 8 kV human body model |
| Common mode transient immunity | above 25 kV per microsecond |
| Supply current, logic side | 3.0 mA unloaded, 50 mA at 16 Mbps |
| Supply current, bus side | 4.0 mA unloaded |
| Package and range | 16-lead wide body SOIC, -40 C to +85 C |
Reinforced insulation and where it is required
849 V peak of working voltage with a reinforced rating is 600 V rms, which is the level that insulation coordination for a 400 V three phase system asks for when the barrier is between a hazardous and an accessible circuit. A functional or basic isolation part with the same test voltage does not satisfy that requirement.
The difference shows up in the safety file, not on the bench. A part with a 5000 V rms test rating and a basic insulation classification can pass every electrical test and still require a second barrier in the product. Reading only the test voltage is how that mistake is made.
Half duplex or full duplex from one order code
The part can be wired as a two wire half duplex transceiver or a four wire full duplex one, which means a single order code covers two different bus topologies. The loaded supply current in the table, 50 mA at 16 Mbps, belongs to the half duplex configuration and is the number an isolated supply has to meet.
Full duplex doubles the number of bus pairs and removes the turnaround time from the protocol, which is the reason a 16 Mbps link is often full duplex: at 62.5 ns per bit the turnaround overhead of a half duplex protocol is a large fraction of the frame.
8 kV on the bus pins
The bus pin rating on this part is 8 kV, half the 15 kV of the 500 kbps members. That is a trade the vendor made for speed on the same barrier, and it matters on a connector that is handled. A system that expects a 15 kV event at the connector needs the slower part or external protection.
Inside a cabinet, on a fixed backplane, 8 kV is ample. The rating is a pin rating, not a system rating, and the system rating depends on how the connector is bonded and where the cable shield goes.
Replacement checks
A candidate for this position has to match the insulation classification first, then the working voltage, then the data rate and the duplex configuration. Test voltage alone is not a substitute for the classification, and a higher data rate part with a lower working voltage is not an upgrade.
The pages below hold the family alternatives, the defence grade components route and the acceptance sequence.
Two pages worth reading before a purchase order goes out are the ADI second source page and defense grade components; the first lists what else fits the socket, the second is the test sequence for a drop in, and how to verify a drop in replacement covers the case where the shortage is already on the line.
Two questions buyers ask
Does the ADM2491EBRWZ need a separate isolated supply? Yes, an isolated 5 V on the bus side. The ADM2587E is the family member that generates the isolated rail internally.
Is the 5000 V rms rating a working voltage? No. It is a one minute test voltage. The continuous working voltage is 849 V peak, and that is the figure the insulation coordination calculation uses.