Contact Us

ADM2481BRWZ-RL7

Brand: Analog Devices
Analog Devices ADM2481BRWZ-RL7 is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADM2481BRWZ-RL7 — Analog & Mixed-Signal ICs | Superb Automation

ADM2481BRWZ-RL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADM2481BRWZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

ADM2481BRWZ: isolated half duplex RS-485 at 500 kbps

The ADM2481BRWZ is a galvanically isolated RS-485 transceiver in a 16-lead wide body SOIC, with a logic side that runs from 5 V or 3.3 V and a bus side that runs from an isolated 5 V. The isolation barrier is an iCoupler transformer rather than an optocoupler, which is why the part holds a 656 V peak working voltage and still draws 2.5 mA.

Published values

ParameterValue
Functionisolated half duplex RS-485 transceiver
Data rate500 kbps
Isolation test voltage2500 V rms for one minute
Working voltage656 V peak
Common mode transient immunityabove 25 kV per microsecond
Supply current2.5 mA maximum
Input impedance96 kohm, one eighth of a unit load
Logic side supply5 V or 3.3 V
Bus side supplyisolated 5 V
Package and range16-lead wide body SOIC, -40 C to +85 C

Two isolation numbers, two different meanings

2500 V rms for one minute is a test voltage: the part is stressed at that level briefly and has to survive. 656 V peak is the working voltage, the level it can hold continuously for the life of the equipment. The two are not interchangeable, and a specification that quotes only the test voltage has left out the number the safety case needs.

For a 400 V three phase drive the bus side sits on a node that switches by hundreds of volts, so the working voltage is the relevant figure. 656 V peak is 464 V rms, which covers a 400 V system with the usual margin and does not cover a 690 V system.

500 kbps and the cable it allows

At 500 kbps a bit is 2 us. The barrier adds propagation delay that is not in a non isolated part, so the loop time budget has to include it, and at 2 us per bit there is room. This is the speed at which an isolated transceiver is comfortable on a field bus, which is why the isolated members of this family cluster at 500 kbps and at 16 or 20 Mbps rather than in between.

The 96 kohm input impedance is one eighth of a standard unit load, so the node count on a terminated bus is limited by the cable and the terminators rather than by the transceiver. On a long multidrop run that matters more than the data rate.

2.5 mA and the isolated supply

2.5 mA maximum on the logic side is 12.5 mW at 5 V, which is small enough that the isolated rail can be a charge pump or a small transformer without a thermal problem. The bus side current is separate and is set by the driver load.

The barrier also carries the common mode transient, and the 25 kV per microsecond figure is what stops a switching node from corrupting a data frame. An optocoupler based part with a slower barrier will let a fast edge through as a glitch, which appears as a framing error every time the motor switches.

Replacement checks

The family splits by data rate, by duplex and by working voltage, and the packages differ between the 16-lead and the 20-lead members. A candidate has to match the working voltage first, because that is the safety number, then the data rate, then the bus side supply, which is 5 V here and 3.3 V on the ADM2484E.

The pages below cover the family alternatives, the medical approvals route and the acceptance sequence for a substitute.

Sourcing notes for this family: the ADI second source page holds the cross references, medical device components is the pre substitution check, and how to verify a drop in replacement is what we use when the part on the drawing is not on the shelf.

Two questions buyers ask

Is the ADM2481BRWZ the same as the ADM2483BRWZ? Both are 500 kbps isolated half duplex parts with the same package. The ADM2483 adds true fail safe receiver inputs and thermal shutdown, and its working voltage is 565 V peak rather than 656 V.

Does the bus side need a separate isolated supply? Yes. The logic side runs from 5 V or 3.3 V, and the bus side needs its own isolated 5 V rail. The ADM2587E is the member of the family that generates that rail internally.