ADM202EARUZ-REEL7
Product Specifications
ADM202EARUZ-REEL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADM202EARUZ-REEL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADM202EARUZ-REEL7: a two channel RS-232 transceiver with 15 kV of human body model ESD protection
What this order code is
ADM202EARUZ-REEL7 is a two driver, two receiver RS-232 and V.28 interface device that runs from a single plus 5 V supply and is guaranteed to 230 kbits per second. The E suffix is the enhanced electrostatic discharge version: plus and minus 8 kV on contact discharge to IEC1000-4-2 and plus and minus 15 kV on the human body model, on all input and output lines. The part is compliant with the EMC directive and with the EN55022 and CISPR22 emission limits, and it is a pin compatible upgrade for the MAX202E, the MAX232E, the ADM232L and the older ADM202 sockets.
The charge pump is internal and needs four external 0.1 microfarad capacitors to double and invert the 5 V rail, which is what allows a plus and minus 10 V class RS-232 swing from a single supply. The TSSOP body is 44 percent smaller than the SOIC body of the same part, so the RUZ code is the density choice and not a different electrical device.
Parameters as published
| Item | Value |
|---|---|
| Drivers and receivers | two and two |
| Supply | plus 5 V single supply |
| Data rate | 230 kbits per second guaranteed |
| ESD, contact discharge | plus and minus 8 kV, IEC1000-4-2 |
| ESD, human body model | plus and minus 15 kV |
| Charge pump capacitors | four external 0.1 microfarad |
| EMC | 89/336/EEC, EN55022 and CISPR22 emissions |
| Transient immunity | EFT burst, IEC1000-4-4 |
| Standard | EIA-232E and CCITT V.28 |
| Body | 16-lead TSSOP, DIP and SO also in the family |
| Socket compatibility | MAX202E, MAX232E, ADM232L, ADM202 |
Numbers that decide the application
230 kbits per second is a 4.35 microsecond bit, which is about four times slower than a 1 Mbit part and entirely adequate for a service port, a modem handshake or a legacy instrument link. Buyers regularly ask for a faster pin compatible part on the assumption that the cable is the limit, and the answer is that the charge pump and the four 0.1 microfarad capacitors, not the silicon, set the rate at this supply.
The two ESD numbers are different tests and cannot be ranked against each other. Plus and minus 8 kV contact discharge is a machine model of a charged object touching a connector pin and is the harsher of the two for a panel mounted connector; plus and minus 15 kV human body model is the older handling standard. A product that has to pass a contact discharge test at level 4 needs the 8 kV figure to hold on the pins that reach the outside world, and the part is specified that way on all input and output lines rather than on a subset.
The four 0.1 microfarad capacitors are part of the bill of materials and part of the board area. They also carry the switching current of the pump, so their dielectric and their placement matter: a 0.1 microfarad capacitor that loses most of its value at 5 V leaves the pump short of charge and the RS-232 swing collapses at the far end of a long cable. This is the most common cause of a link that works on the bench and fails in the field.
Where it fits and where it does not
It fits legacy serial ports on industrial terminals, analysers, point of sale equipment and medical instruments, and it is the drop in route for a board that was built around a MAX202E or a MAX232E and now has to survive a higher ESD test. It does not fit a 3.3 V only system, because the part is a 5 V device and the charge pump is sized around that rail, and it does not fit a link that needs more than 230 kbits per second.
Supply and second source questions
The questions are about the supply, the data rate, the capacitor count and whether a 3.3 V part can be dropped into the same socket. The MAX202E pinout is common across several vendors, so a cross reference has to match the ESD grade and the data rate as well as the pinout; a part that is pin compatible but rated at 120 kbits per second is not a substitute in a 230 kbit link. The RS-232 class parts are listed with their equivalents on the second source page.
Sourcing notes and next step
We quote this code against the bill of materials and check the ESD grade, the data rate, the body and the packing, and we flag any substitution that changes the ESD class even when the pinout is identical. The four charge pump capacitors are quoted with the device where the line asks for a kit. Send the line items, quantities and required date through the BOM shortage recovery page, and for instrumentation and analyser platforms that need the same interface over a long production life, the medical device components page covers the parts we keep available for that cycle.