Contact Us

ADG5404FBRUZ-RL7

Brand: Analog Devices
Analog Devices ADG5404FBRUZ-RL7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADG5404FBRUZ-RL7 — Analog & Mixed-Signal ICs | Superb Automation

ADG5404FBRUZ-RL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADG5404FBRUZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADG5404FBRUZ-RL7: A Four to One Multiplexer That Survives 55 Volts on a 15 Volt Rail

The ADG5404FBRUZ-RL7 is a four channel analog multiplexer with fault protection and detection on the source pins, 10 ohm typical on resistance, 0.5 ohm maximum on resistance flatness and 4 kV human body model ESD rating. It runs from plus and minus 5 V to plus and minus 22 V dual, or 8 V to 44 V single, and it reports a fault on a digital flag while holding the drain in a defined state. It exists because real sensors fail, and a failed sensor that puts 55 V onto a 15 V multiplexer destroys every channel behind it.

Fault protection is a system specification

On plus and minus 15 V rails, a plus 55 V fault is 40 V above the positive rail. The channel turns off when the source exceeds the rail by the fault threshold, the source pin becomes high impedance, and the drain either floats or pulls to the exceeded rail depending on the DR pin. That behaviour has to be matched to what the converter behind it can tolerate: a floating drain is safe for a high impedance input, and a drain pulled to the rail is safer for an input that must not be left undefined. Choosing between the two is a system decision, and it is set by one pin.

What the published figures convert to

ParameterPublished figureWhat it means on a board
ConfigurationFour to one, addressed by two lines plus an enableFour single ended sensors into one converter input
On resistance10 ohm typical10 ppm of error into a 1 Mohm input, and 0.1 percent into 10 kohm
On resistance flatness0.5 ohm maximum5 percent of the on resistance, so distortion across the signal range stays low
Fault protectionMinus 55 V to plus 55 V on the source pins40 V above a plus 15 V rail, whether the part is powered or not
Power off protectionUp to 55 V with no suppliesA card that loses power does not load the field wiring
Fault detectionDigital flag per deviceThe processor knows a channel is faulted instead of reading a plausible wrong value
Drain responseFloating or pulled to the exceeded rail, set by the DR pinMatches the fault behaviour to the converter input structure
ESD4 kV human body modelField wiring and handling are covered without extra clamps on the connector
Latch-upImmune by trench isolationA fault event does not leave the part in a latched state after power is restored
Signal rangeVSS to VDDRail to rail analog signal with no separate charge pump
SuppliesPlus and minus 5 V to plus and minus 22 V, or 8 V to 44 V singleOne part covers a plus and minus 15 V industrial front end and a 24 V single supply unit
Package16 lead TSSOPThe same footprint family as unprotected multiplexers in the same range

Checks before accepting a cross reference

  • Confirm fault protection applies to the source pins in both powered and unpowered states. Many parts protect only when powered.
  • Check whether fault detection is a flag or an implied behaviour. Without a flag, a fault is indistinguishable from a valid reading.
  • Compare on resistance flatness, not just on resistance. Flatness sets the distortion, and a 5 ohm flat part is unusable in a measurement path.
  • Verify the DR pin behaviour against the converter. A drain that pulls to the rail can forward bias an input protection diode.
  • Ask for the fault threshold and its tolerance, since a threshold that is too high lets a moderate overvoltage through.

Where this part is used

Industrial data acquisition, process control front ends, medical instrument inputs, automotive sensor interfaces and any multiplexed input that is connected to field wiring. It is also used in defence and aerospace systems where a single fault must not propagate into the measurement chain.

Questions buyers ask

Does the part survive a continuous 55 V fault? It blocks the fault and reports it. The part is not a fuse and does not absorb the fault energy, so the external wiring still needs its own protection.

What is the fault response time? The channel turns off when the threshold is crossed, within the switching time of the device. The flag follows the channel state.

Can it be used as a demultiplexer? Yes. The switches conduct equally in both directions, so the same part distributes one signal to four destinations.

Sourcing notes and next step

The multiplexer belongs to the switch and multiplexer group on the analog and mixed signal index. Front ends that have to meet defence grade documentation are described in the defence grade components page, and the converter behind the multiplexer is compared in the ADC and DAC cross reference. Send the supply rails, the fault voltage and the channel count and we will quote the reel and confirm the packaging.

Request Quote — In Stock, 100% New & Original, Full Warranty