ADG5404FBRUZ-RL7
Product Specifications
ADG5404FBRUZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADG5404FBRUZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADG5404FBRUZ-RL7: A Four to One Multiplexer That Survives 55 Volts on a 15 Volt Rail
The ADG5404FBRUZ-RL7 is a four channel analog multiplexer with fault protection and detection on the source pins, 10 ohm typical on resistance, 0.5 ohm maximum on resistance flatness and 4 kV human body model ESD rating. It runs from plus and minus 5 V to plus and minus 22 V dual, or 8 V to 44 V single, and it reports a fault on a digital flag while holding the drain in a defined state. It exists because real sensors fail, and a failed sensor that puts 55 V onto a 15 V multiplexer destroys every channel behind it.
Fault protection is a system specification
On plus and minus 15 V rails, a plus 55 V fault is 40 V above the positive rail. The channel turns off when the source exceeds the rail by the fault threshold, the source pin becomes high impedance, and the drain either floats or pulls to the exceeded rail depending on the DR pin. That behaviour has to be matched to what the converter behind it can tolerate: a floating drain is safe for a high impedance input, and a drain pulled to the rail is safer for an input that must not be left undefined. Choosing between the two is a system decision, and it is set by one pin.
What the published figures convert to
| Parameter | Published figure | What it means on a board |
|---|---|---|
| Configuration | Four to one, addressed by two lines plus an enable | Four single ended sensors into one converter input |
| On resistance | 10 ohm typical | 10 ppm of error into a 1 Mohm input, and 0.1 percent into 10 kohm |
| On resistance flatness | 0.5 ohm maximum | 5 percent of the on resistance, so distortion across the signal range stays low |
| Fault protection | Minus 55 V to plus 55 V on the source pins | 40 V above a plus 15 V rail, whether the part is powered or not |
| Power off protection | Up to 55 V with no supplies | A card that loses power does not load the field wiring |
| Fault detection | Digital flag per device | The processor knows a channel is faulted instead of reading a plausible wrong value |
| Drain response | Floating or pulled to the exceeded rail, set by the DR pin | Matches the fault behaviour to the converter input structure |
| ESD | 4 kV human body model | Field wiring and handling are covered without extra clamps on the connector |
| Latch-up | Immune by trench isolation | A fault event does not leave the part in a latched state after power is restored |
| Signal range | VSS to VDD | Rail to rail analog signal with no separate charge pump |
| Supplies | Plus and minus 5 V to plus and minus 22 V, or 8 V to 44 V single | One part covers a plus and minus 15 V industrial front end and a 24 V single supply unit |
| Package | 16 lead TSSOP | The same footprint family as unprotected multiplexers in the same range |
Checks before accepting a cross reference
- Confirm fault protection applies to the source pins in both powered and unpowered states. Many parts protect only when powered.
- Check whether fault detection is a flag or an implied behaviour. Without a flag, a fault is indistinguishable from a valid reading.
- Compare on resistance flatness, not just on resistance. Flatness sets the distortion, and a 5 ohm flat part is unusable in a measurement path.
- Verify the DR pin behaviour against the converter. A drain that pulls to the rail can forward bias an input protection diode.
- Ask for the fault threshold and its tolerance, since a threshold that is too high lets a moderate overvoltage through.
Where this part is used
Industrial data acquisition, process control front ends, medical instrument inputs, automotive sensor interfaces and any multiplexed input that is connected to field wiring. It is also used in defence and aerospace systems where a single fault must not propagate into the measurement chain.
Questions buyers ask
Does the part survive a continuous 55 V fault? It blocks the fault and reports it. The part is not a fuse and does not absorb the fault energy, so the external wiring still needs its own protection.
What is the fault response time? The channel turns off when the threshold is crossed, within the switching time of the device. The flag follows the channel state.
Can it be used as a demultiplexer? Yes. The switches conduct equally in both directions, so the same part distributes one signal to four destinations.
Sourcing notes and next step
The multiplexer belongs to the switch and multiplexer group on the analog and mixed signal index. Front ends that have to meet defence grade documentation are described in the defence grade components page, and the converter behind the multiplexer is compared in the ADC and DAC cross reference. Send the supply rails, the fault voltage and the channel count and we will quote the reel and confirm the packaging.
Request Quote — In Stock, 100% New & Original, Full Warranty