ADF4001BRUZ
Product Specifications
ADF4001BRUZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADF4001BRUZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADF4001BRUZ: 200 MHz clock generator PLL with a separate charge pump supply
The ADF4001BRUZ is an integer N phase locked loop synthesizer in a 16-lead TSSOP with a 200 MHz bandwidth, a 2.7 V to 5.5 V supply and a separate charge pump supply pin. It contains the phase frequency detector, the charge pump, a 14-bit reference counter and a 13-bit N counter, and it draws 4.5 mA. It is the part for a clean clock that is derived from a reference, not for a radio channel.
Published values
| Parameter | Value |
|---|---|
| Maximum input frequency | 200 MHz |
| Supply range | 2.7 V to 5.5 V |
| Charge pump supply | separate VP pin, allows a tuning voltage above the 5 V rail |
| Reference counter | 14 bits |
| N counter | 13 bits, minimum value of 1 |
| Charge pump current | programmable |
| Interface | 3-wire serial |
| Lock detect | analog and digital |
| Power down | hardware and software |
| Supply current | 4.5 mA typical |
| Compatibility | hardware compatible with the ADF4110, ADF4111, ADF4112 and ADF4113 |
| Packages | 16-lead TSSOP and 20-lead LFCSP |
What a 14-bit R counter and a 13-bit N counter give
The reference counter divides the input by up to 16383, and the N counter divides the feedback by up to 8191. With a 10 MHz reference divided by 100 the phase detector runs at 100 kHz, and an N value of 1000 puts the output at 100 MHz. The smallest step at the output is the phase detector frequency, so 100 kHz of step is what those two numbers buy, and a 25 kHz step needs a 25 kHz phase detector or a fractional part this device does not have.
A 200 MHz input with a 25 kHz phase detector is a division ratio of 8000, which fits the 13-bit N counter with room to spare. The same output with a 1 MHz phase detector needs N of 200, and the loop filter then has to reject the reference spurs that a 1 MHz comparison produces.
The separate charge pump supply
The VP pin lets the charge pump run from a higher voltage than the logic supply, which is how a 5 V system gets a tuning voltage that reaches 8 V or 10 V without a second regulator for the whole chip. A VCO whose tuning range is centred at 6 V is outside the reach of a 5 V charge pump, and the VP pin is the difference between using that VCO and choosing another one.
The charge pump current is programmable, which sets the loop gain together with the filter components. A higher current gives a wider loop bandwidth and faster settling at the cost of reference spurs and phase noise from the detector, so the current is a loop decision and not a register default.
Lock detect and power down
Both an analog and a digital lock detect are available. The digital one gives a logic output when the phase error has stayed inside a window for a number of cycles, which is what a system controller needs before it switches a clock into a datapath. The analog one is a voltage proportional to the phase error, useful while the loop is being characterised.
Hardware and software power down let the device be parked without removing the supply, and the 4.5 mA operating current drops to a leakage level. In a clock tree that has to keep one output alive while the rest is off, that is the difference between a controlled state and a powered down rail that takes milliseconds to recover.
Buyers usually arrive at component lead time solutions to find the family alternatives, then use one stop BOM sourcing to confirm a substitute before it is fitted; the obsolete part cross reference hub is the routine for a part that has already stopped shipping.
Two questions buyers ask
Can the ADF4001 generate 200 MHz from a 10 MHz reference in 25 kHz steps? No. The output step equals the phase detector frequency, so 25 kHz steps need a 25 kHz comparison, and 200 MHz divided by 25 kHz is 8000, which fits the 13-bit N counter. What it cannot do is produce a step smaller than the comparison frequency.
Does it need an external VCO? Yes. The ADF4001 is a synthesizer only, so the VCO or VCXO, the loop filter and the charge pump supply decoupling are all external. A part with an integrated VCO is a different order code in the same family.