Contact Us

ADE7880ACPZ-RL

Brand: Analog Devices
Analog Devices ADE7880ACPZ-RL is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADE7880ACPZ-RL — Analog & Mixed-Signal ICs | Superb Automation

ADE7880ACPZ-RL

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADE7880ACPZ-RL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADE7880ACPZ: Three Phase Metering with Harmonic Analysis Inside

What this part is

The ADE7880 is a three phase energy measurement IC that does more than total active energy. It carries second order sigma delta converters, a digital integrator, the reference and a fixed function signal processor whose program sits in internal ROM, and it reports rms, active, reactive and apparent power, power factor, total harmonic distortion and the amplitude of every harmonic inside a 2.8 kHz pass band on all phases and on the neutral current. Total and fundamental only energy are both available, which is what a meter needs when the tariff separates fundamental reactive energy from harmonic content. Three pulse outputs, CF1 to CF3, can be assigned to different power quantities for calibration and for a mechanical pulse counter.

Published figures that matter to a buyer

Services supported3 phase, 3 or 4 wire, delta or wye
Standards quotedIEC 62053-21, 62053-22, 62053-23, EN 50470-1, EN 50470-3, ANSI C12.20, IEEE 1459
Harmonic standardIEC 61000-4-7 Class I and Class II accuracy
Harmonic pass band2.8 kHz on phase and neutral
Active and fundamental reactive energyless than 0.1 percent error over 1000 to 1, at 25 degrees C
Same, wider rangeless than 0.2 percent error over 5000 to 1
Harmonic rms and harmonic powerless than 1 percent error over 2000 to 1
Calibration per phaserms offset, phase and gain
Pulse outputsCF1, CF2, CF3
Computationfixed function processor, program in internal ROM
Package on this codeLFCSP

Where the headline numbers stop

The 2.8 kHz pass band is the first limit to check against the standard being claimed. At 50 Hz it reaches the 56th harmonic; at 60 Hz it reaches the 46th, so a Class II harmonic report that runs to the 50th harmonic is inside the band on a 50 Hz network and outside it on a 60 Hz one. A meter aimed at both markets needs that written down before the accuracy claim goes on a datasheet, because the 2.8 kHz figure is a property of the part and not of the network.

The energy accuracy figures are quoted at 25 degrees C and over a dynamic range, which is a specific measurement and not a general promise. Less than 0.1 percent over 1000 to 1 on a 60 A meter means 60 mA; the 0.2 percent figure extends that to 12 mA over 5000 to 1, and the harmonic figures are a looser 1 percent over 2000 to 1, so the harmonic path is ten times coarser than the fundamental energy path. Temperature drift, the shunt or current transformer error and the crystal are all outside those numbers, and in a Class 0.2S meter the current sensor is usually the dominant term rather than the IC. The calibration is per phase, so a three phase board needs three gain, three phase and three offset coefficients written at test, which is a fixture time cost that shows up in the production plan.

Applications where it fits

  • Three phase revenue meters that must report harmonics as well as energy, for a network operator that penalises distortion.
  • Sub-metering and tenant billing in commercial buildings where the load is unbalanced and neutral current matters.
  • Power quality instruments that need per harmonic amplitude without an external processor.
  • Charging equipment and inverter front panels that monitor their own consumption against a tariff.

Two questions buyers ask

Can one part serve both 3 wire and 4 wire services? Yes, the same device covers 3 wire and 4 wire, delta and wye, and the configuration is a register setting rather than a different order code. The current and voltage channel count does not change, so the same board can be built once and configured at test for the service it will be installed on.

Is an external processor needed? Not for the measurement. The fixed function processor runs from internal ROM and produces the results in registers, so the host only reads them and handles the display, the tariff clock and the communication port. That is also the limit: the harmonic set is fixed by the internal program, and a customer who wants a different harmonic grouping needs a different device rather than a firmware change.

Sourcing notes and next step

The ADE7880ACPZ is the LFCSP body used on most meter boards in this family. The practical question on a metering line is not availability of the die but the calibration fixture and the reference meter, because a part swap inside the same family keeps the pinout and the register map but not necessarily the calibration constants. We supply the family with date code traceability and can quote the alternative members where the harmonic requirement is not needed. The analog and mixed signal IC family page lists the metering line, the ADC and DAC cross reference page compares the converter families behind these parts, and the BOM shortage recovery page covers the case where the metering IC is the long lead item on the board.

Request Quote — In Stock, 100% New & Original, Full Warranty