Contact Us

ADE7878AACPZ-RL

Brand: Analog Devices
Analog Devices ADE7878AACPZ-RL is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADE7878AACPZ-RL — Analog & Mixed-Signal ICs | Superb Automation

ADE7878AACPZ-RL

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADE7878AACPZ-RL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADE7878AACPZ-RL: three phase energy metering with 0.2 percent over a 3000 to 1 range

What this order code is

ADE7878AACPZ-RL is the top member of the ADE7854A, ADE7858A, ADE7868A and ADE7878A family of polyphase energy measurement ICs, in a 40 lead LFCSP on a reel. It contains second order sigma delta converters, a digital integrator, the reference, a fixed function DSP with its program in internal ROM, and three pulse outputs, and it computes total and fundamental active and reactive energy plus apparent energy and rms values for a three phase service.

The family covers three wire and four wire services in delta and wye connection, and it accepts both current transformers and di/dt sensors such as Rogowski coils, which is the pair of sensor types that a meter platform has to support because the two are used in different price bands. A dedicated converter channel handles neutral current directly, and where no neutral sensor is fitted the part estimates neutral current from the rms of the sum of the three phase currents.

Parameters as published

ItemValue
Service types3 phase, 3 or 4 wire, delta or wye
Active and reactive error0.1 percent typical over 1000 to 1 at 25 C
Active and reactive error0.2 percent typical over 3000 to 1 at 25 C
Energy quantitiestotal and fundamental, per phase and system
Apparent energycomputed
rms registersaveraged, low ripple
Current sensorscurrent transformer and di/dt
Neutral currentdedicated ADC channel
Neutral estimaterms of the sum of the three phase currents
Converter architecturesecond order sigma delta
Pulse outputsthree, flexible
Standards namedEN 50470-1, EN 50470-3, IEC 62053-21, -22, -23
Body40 lead LFCSP
Packingreel

Numbers that decide the application

The two accuracy figures are the whole specification argument. 0.1 percent over 1000 to 1 is 60 dB of dynamic range and 0.2 percent over 3000 to 1 is 69.5 dB, so the part keeps its accuracy down to one three thousandth of full scale, which is what a revenue meter needs to bill a standby load of a few watts on a 100 A service. Both figures are typical at 25 degrees C, and a meter class is a limit over temperature and over the life of the product, so the margin between the typical figure and the class limit is what the calibration and the thermal behaviour of the shunts have to deliver, not something the data sheet hands over.

The standards list tells a buyer which meter classes the platform can reach. IEC 62053-21 covers class 1 and class 2 active energy, IEC 62053-22 covers class 0.5S and 0.2S, and IEC 62053-23 covers reactive energy, while EN 50470-1 and EN 50470-3 are the European equivalents for the meter as a product. A 0.2 percent typical part is the entry point for a class 0.5S meter and is not by itself a class 0.2S product, which needs the error over the full current range and over temperature to stay inside 0.2 percent including the sensor.

Real time values update every 8 kHz, which is 125 microseconds, so the accumulated energy registers are computed far faster than any billing interval and the limit on response time is the averaging window the firmware chooses rather than the converter. The fundamental only path is what separates this part from the cheaper members of the family: a site with harmonic distortion needs the fundamental active energy to bill correctly, and a part that only reports total energy cannot separate the two.

Where it fits and where it does not

It fits three phase revenue meters, power quality analysers, industrial sub metering, EV charging stations and data centre branch circuit monitoring, in both transformer and Rogowski based current sensing. It does not fit a single phase product, where the smaller members of the family are cheaper and simpler, and it does not fit a product that needs a class 0.2S certificate without the sensor and the calibration chain being part of the qualification. It also expects a proper reference and a clean ground around it, because 0.1 percent metering is a system property and not a chip property.

Supply and second source questions

The questions that come back on this code are about the family member, the sensor type and the calibration route. The four parts in the family differ in which energy quantities they compute, so the suffix letter matters more than the family name in a bill of materials. Sensor type is a register configuration and an external component change, not a different order code, and the neutral channel is either wired or estimated. Metering front ends that carry the same standards list and parts that only cover single phase are separated on the converter and multiplexer cross reference page.

Sourcing notes and next step

We quote this code against the bill of materials and confirm the fields that decide whether the reel is usable: family member, body, packing and grade. A line that names ADE78 without the trailing letters can mean any of four parts with different energy quantities, and the metering firmware expects the one it was written for. Send the line items, quantities and required date through the BOM shortage recovery page and we will answer with availability, and where the exact code is short we will say so rather than move the line to a family member that drops the fundamental measurement. The wider converter list sits on the analog and mixed signal IC page.

ADE7878AACPZ-RL pulse output arithmetic: what a 6400 impulse constant means at 100 A and at 3000 to 1

A meter built on this part produces energy as a pulse frequency, and the frequency is where the accuracy claim meets the test bench. With the common 6400 impulses per kilowatt hour constant and a 240 V, 100 A service, full load is 24 kW and 153,600 impulses per hour, which is 42.7 impulses per second and a pulse every 23.4 ms. Ten percent load is 2.4 kW and 4.27 impulses per second. One percent is 240 W and one pulse every 2.3 s. At the bottom of the 3000 to 1 range the load is 8 W and the pulse period is 70 s, and that single number explains why a 0.2 percent check at the bottom of the range takes minutes rather than seconds per point.

Why the class limit and the typical figure are different numbers

The published 0.2 percent over 3000 to 1 is typical at 25 C. A class 0.5S meter has to hold 0.5 percent over the current range, over temperature and over the life of the product, with the sensor included. The distance between 0.2 percent typical and 0.5 percent over everything is the budget for the current sensor, the reference drift, the temperature coefficient of the shunts and the calibration interval. A platform that measures 0.2 percent on the bench is at the entry point for class 0.5S, not at the entry point for class 0.2S, and the difference between those two products is a calibration and sensor question rather than a converter question.

Three pulse outputs and what each is for

The part provides three flexible pulse outputs. In practice one carries active energy, one reactive energy and one is used for a calibration or verification output, which lets a test bench read a fast pulse during calibration and a slow one in the field without reconfiguring the meter. The value to a buyer is that the pulse constant can be set per output, so the same platform serves a 1000 impulse meter and a 10,000 impulse meter without a firmware change, and the test bench time falls with it.

Neutral current without a neutral sensor

A dedicated converter channel takes a neutral current sensor, and where no neutral sensor is fitted the part computes neutral current from the root sum square of the three phase currents. That estimate is exact only when the three currents sum to zero, which is the normal case in a four wire service and is not the case when there is a neutral to earth path. A meter that bills on the estimate in a service with a neutral current has an error term that no calibration removes, so the choice of fitting the fourth sensor is a decision about the installation rather than about cost.

Load on a 100 A servicePower at 240 VImpulses per hour at 6400 per kWhImpulses per secondPulse period
100 A, full scale24 kW153,60042.723.4 ms
10 A, 10 percent2.4 kW15,3604.27234 ms
1 A, 1 percent240 W1,5360.4272.34 s
100 mA, 0.1 percent24 W153.60.042723.4 s
33 mA, 3000 to 18 W51.10.014270.4 s

Converter equivalents for metering are on ADC DAC cross reference, consolidated ordering for a meter platform is on one stop BOM sourcing, and programme level purchasing is on OEM procurement.

Request Quote — In Stock, 100% New & Original, Full Warranty